RMON-MIB Agent Capabilities.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.15004.6.30.9.2
RMON-MIB Agent Capabilities.
Identification
{1 3 6 1 4 1 15004 6 30 9 2}
The displayed source records contain one distinct definition. Compare its source records.
ruggedcomRmonAC01 AGENT-CAPABILITIES
PRODUCT-RELEASE "Ruggedcom ROX 2.4.1"
STATUS current
DESCRIPTION
"RMON-MIB Agent Capabilities."
SUPPORTS RMON-MIB
-- rfc2819.txt
INCLUDES {rmonEtherStatsGroup }
-- ROS supports the following groups that we don't support yet
-- rmonHistoryControlGroup,rmonEthernetHistoryGroup
-- rmonAlarmGroup
-- rmonEventGroup
VARIATION etherStatsOwner
DESCRIPTION
"The value of this entry is always set to 'Monitor' and
may not be modified."
VARIATION etherStatsStatus
DESCRIPTION
"One entry per port is created in etherStatsTable upon
initialization up. These entries may not be modified
or deleted.
No new entries can be created.
Therefore, historyControlStatus always set to 'valid(1)'."
VARIATION historyControlIndex
DESCRIPTION
"An average of four entries per ethernet port can be created
in historyControlTable."
VARIATION historyControlBucketsRequested
SYNTAX Integer32(1..4000)
DESCRIPTION
"The value of historyControBucketRequested is restricted
to 4000."
VARIATION historyControlOwner
SYNTAX OwnerString
DEFVAL { "Monitor" }
DESCRIPTION
"A default value of a historyControlOwner is a
'Monitor' string."
VARIATION alarmIndex
DESCRIPTION
"An average of four entries per port can be created
in alarmTable."
VARIATION alarmInterval
SYNTAX Integer32
DEFVAL { 60 }
DESCRIPTION
"A default value of an alarmInterval is 60 seconds."
VARIATION alarmSampleType
SYNTAX INTEGER {
absosluteValue(1),
deltaValue(2)
}
DEFVAL { deltaValue }
DESCRIPTION
"A default value of an alarmSampleType is 'deltaValue(2)'."
VARIATION alarmStartupAlarm
SYNTAX INTEGER {
risingAlarm(1),
fallingAlarm(2),
risingOrFallingAlarm(3)
}
DEFVAL { risingOrFallingAlarm }
DESCRIPTION
"A default value of alarmStartupAlarm is
'risingOrFallingAlarm(3)'."
-- VARIATION alarmOwner --
-- DEFVAL { "Monitor" } --
-- DESCRIPTION --
-- "A default value of an alarmOwner is a 'Monitor' --
-- string." --
VARIATION eventIndex
DESCRIPTION
"An average of one entry per alarmEntry may be created
in eventTable."
VARIATION eventType
SYNTAX INTEGER {
none(1),
log(2),
snmptrap(3),
logandtrap(4)
}
DEFVAL { none }
DESCRIPTION
"A default value of an eventType is 'logandtrap(4)'."
VARIATION eventCommunity
DESCRIPTION
"The string of up to 30 characters is supported for this
object."
VARIATION eventOwner
SYNTAX OwnerString
DEFVAL { "Monitor" }
DESCRIPTION
"A default value of an eventOwner is a 'Monitor' string."
VARIATION logIndex
DESCRIPTION
"For each eventEntry a hundred of entries in logTable may
be created. The value of this object will increase for each
new log generated for coresponding event. When value of
this object becomes greater than 100, oldest entries will
be deleted."
-- ---------------------------------------------------------------------- --
::= { ruggedcomRmonACModule 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
RMON-MIB Agent Capabilities.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: ruggedcomRmonAC01
{
"smi_kind": "AGENT-CAPABILITIES",
"definition": [
"ruggedcomRmonAC01",
"AGENT-CAPABILITIES",
"PRODUCT-RELEASE",
[
"literal",
"22527567676564636f6d20524f5820322e342e3122"
],
"STATUS",
"current",
"DESCRIPTION",
"\"RMON-MIB Agent Capabilities.\"",
"SUPPORTS",
"RMON-MIB",
"INCLUDES",
"{",
"rmonEtherStatsGroup",
"}",
"VARIATION",
"etherStatsOwner",
"DESCRIPTION",
"\"The value of this entry is always set to 'Monitor' and may not be modified.\"",
"VARIATION",
"etherStatsStatus",
"DESCRIPTION",
"\"One entry per port is created in etherStatsTable upon initialization up. These entries may not be modified or deleted. No new entries can be created. Therefore, historyControlStatus always set to 'valid(1)'.\"",
"VARIATION",
"historyControlIndex",
"DESCRIPTION",
"\"An average of four entries per ethernet port can be created in historyControlTable.\"",
"VARIATION",
"historyControlBucketsRequested",
"SYNTAX",
"Integer32",
"(",
"1",
".",
".",
"4000",
")",
"DESCRIPTION",
"\"The value of historyControBucketRequested is restricted to 4000.\"",
"VARIATION",
"historyControlOwner",
"SYNTAX",
"OwnerString",
"DEFVAL",
"{",
[
"literal",
"224d6f6e69746f7222"
],
"}",
"DESCRIPTION",
"\"A default value of a historyControlOwner is a 'Monitor' string.\"",
"VARIATION",
"alarmIndex",
"DESCRIPTION",
"\"An average of four entries per port can be created in alarmTable.\"",
"VARIATION",
"alarmInterval",
"SYNTAX",
"Integer32",
"DEFVAL",
"{",
"60",
"}",
"DESCRIPTION",
"\"A default value of an alarmInterval is 60 seconds.\"",
"VARIATION",
"alarmSampleType",
"SYNTAX",
"INTEGER",
"{",
"absosluteValue",
"(",
"1",
")",
",",
"deltaValue",
"(",
"2",
")",
"}",
"DEFVAL",
"{",
"deltaValue",
"}",
"DESCRIPTION",
"\"A default value of an alarmSampleType is 'deltaValue(2)'.\"",
"VARIATION",
"alarmStartupAlarm",
"SYNTAX",
"INTEGER",
"{",
"risingAlarm",
"(",
"1",
")",
",",
"fallingAlarm",
"(",
"2",
")",
",",
"risingOrFallingAlarm",
"(",
"3",
")",
"}",
"DEFVAL",
"{",
"risingOrFallingAlarm",
"}",
"DESCRIPTION",
"\"A default value of alarmStartupAlarm is 'risingOrFallingAlarm(3)'.\"",
"VARIATION",
"eventIndex",
"DESCRIPTION",
"\"An average of one entry per alarmEntry may be created in eventTable.\"",
"VARIATION",
"eventType",
"SYNTAX",
"INTEGER",
"{",
"none",
"(",
"1",
")",
",",
"log",
"(",
"2",
")",
",",
"snmptrap",
"(",
"3",
")",
",",
"logandtrap",
"(",
"4",
")",
"}",
"DEFVAL",
"{",
"none",
"}",
"DESCRIPTION",
"\"A default value of an eventType is 'logandtrap(4)'.\"",
"VARIATION",
"eventCommunity",
"DESCRIPTION",
"\"The string of up to 30 characters is supported for this object.\"",
"VARIATION",
"eventOwner",
"SYNTAX",
"OwnerString",
"DEFVAL",
"{",
[
"literal",
"224d6f6e69746f7222"
],
"}",
"DESCRIPTION",
"\"A default value of an eventOwner is a 'Monitor' string.\"",
"VARIATION",
"logIndex",
"DESCRIPTION",
"\"For each eventEntry a hundred of entries in logTable may be created. The value of this object will increase for each new log generated for coresponding event. When value of this object becomes greater than 100, oldest entries will be deleted.\"",
"::=",
"{",
"ruggedcomRmonACModule",
"2",
"}"
],
"syntax_tree": [
[
"PRODUCT-RELEASE",
"Ruggedcom ROX 2.4.1"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"RMON-MIB Agent Capabilities."
],
null
]
}Vendor MIB copy from the Observium Community archive.
Module: RC-RMON-MIB-AC
See published definition above
{'RMON-MIB': ['OwnerString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'Integer32'], 'SNMPv2-CONF': ['AGENT-CAPABILITIES'], 'RUGGEDCOM-MIB': ['ruggedcomAgentCapability']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.15004.6.30.9.1 | ruggedcomRmonAC | 0 | 0 |