OID reference

fanRPMs

1.3.6.1.4.1.15497.1.1.1.10.1.2

Description

Fan speed in RPMs.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.15497.1.1.1.10.1 (fanEntry)
Node code
2
Node name
fanRPMs
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.15497.1.1.1.10.1.2
URN notation
urn:oid:1.3.6.1.4.1.15497.1.1.1.10.1.2
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 15497 1 1 1 10 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ironPort(15497) asyncOSAppliances(1) asyncOSMail(1) asyncOSMailObjects(1) fanTable(10) fanEntry(1) fanRPMs(2)}
OID-IRI notation
  • /1/3/6/1/4/1/15497/1/1/1/10/1/2
  • /ISO/Identified-Organization/6/1/4/1/15497/1/1/1/10/1/2
  • /ISO/3/6/1/4/1/15497/1/1/1/10/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/ironPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/identified-organization/dod/internet/private/enterprise/IronPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/identified-organization/dod/internet/private/enterprises/ironPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/identified-organization/dod/internet/private/enterprises/IronPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ironPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/IronPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/identified-organization/dod/internet/private/vendor-objects/ironPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/identified-organization/dod/internet/private/vendor-objects/IronPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/org/dod/internet/private/enterprise/ironPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/org/dod/internet/private/enterprise/IronPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/org/dod/internet/private/enterprises/ironPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/org/dod/internet/private/enterprises/IronPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/org/dod/internet/private/ldap-enterprise/ironPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/org/dod/internet/private/ldap-enterprise/IronPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/org/dod/internet/private/vendor-objects/ironPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • /iso/org/dod/internet/private/vendor-objects/IronPort/asyncOSAppliances/asyncOSMail/asyncOSMailObjects/fanTable/fanEntry/fanRPMs
  • Additional combinations skipped.

SNMP properties

Value type
Gauge32
Maximum access defined by MIB
read-only
Status in MIB
current, mandatory

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Cisco MIB copies (LibreNMS/Observium Community)

Value type
Gauge32
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 2 — MIBdepot

Value type
Gauge32
Maximum access defined by MIB
read-only
Status in MIB
mandatory

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In ASYNCOS-MAIL-MIB, the row index fanIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.15497.1.1.1.10.1.2.<fanIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.15497.1.1.1.10.1.2

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

fanRPMs OBJECT-TYPE
    SYNTAX     Gauge32
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
        "Speed in RPMs of a chassis fan being instrumented. The speed
         that corresponds to a fan failure varies depending on the
         vendor specification and airflow requirements for the
         appliance it's instrumented in, but in general when fanRPMs
         reports 0 RPMs the respective fan has failed."
    ::= { fanEntry 2 }

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 2

Speed in RPMs of a chassis fan being instrumented. The speed that corresponds to a fan failure varies depending on the vendor specification and airflow requirements for the appliance it's instrumented in, but in general when fanRPMs reports 0 RPMs the respective fan has failed.

Sources for this description

Cisco MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 2Cisco MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

fanRPMs · currentCisco MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: fanRPMs

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "fanRPMs",
    "OBJECT-TYPE",
    "SYNTAX",
    "Gauge32",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Speed in RPMs of a chassis fan being instrumented. The speed that corresponds to a fan failure varies depending on the vendor specification and airflow requirements for the appliance it's instrumented in, but in general when fanRPMs reports 0 RPMs the respective fan has failed.\"",
    "::=",
    "{",
    "fanEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "ApplicationSyntax",
      "Gauge32"
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Speed in RPMs of a chassis fan being instrumented. The speed that corresponds to a fan failure varies depending on the vendor specification and airflow requirements for the appliance it's instrumented in, but in general when fanRPMs reports 0 RPMs the respective fan has failed."
    ],
    null,
    null,
    null,
    null
  ]
}

Historical records

Additional source information

Information from OID Repository
Vendor: IronPort
Module: ASYNCOS-MAIL-MIB (ASYNCOS-MAIL-MIB)
Type: TABULAR
Access: read-only
Syntax: Gauge32

Automatically extracted from www.mibdepot.com
Information from MIBdepot
fanRPMs OBJECT-TYPE
    SYNTAX Gauge32
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Fan speed in RPMs."
    ::= { fanEntry 2 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.15497)

Slater Charles

Siblings (2)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.15497.1.1.1.10.1.1 fanIndex00 Index into fanTable.
1.3.6.1.4.1.15497.1.1.1.10.1.3 fanName00 Name of Fan. E.g., FAN 1.