systemDeviceCheckSystemDeviceFailed

1.3.6.1.4.1.1608.1.1.1.9.1.0.132

Description

Consistency check on logical drive failed.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1608.1.1.1.9.1.0 (0)
Node code
132
Node names
  • systemDeviceCheckSystemDeviceFailed
  • fCArrayAssistant33
  • sysdevCheckSysdevFailed
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.1608.1.1.1.9.1.0.132
URN notation
urn:oid:1.3.6.1.4.1.1608.1.1.1.9.1.0.132
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1608 1 1 1 9 1 0 132}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) dmtfGroups(1) tMylexRaidEventInformation(9) eMylexRaidEventInformation(1) 0 systemDeviceCheckSystemDeviceFailed(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) dmtfGroups(1) tMylexRaidEventInformation(9) eMylexRaidEventInformation(1) 0 fCArrayAssistant33(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) dmtfGroups(1) tMylexRaidEventInformation(9) eMylexRaidEventInformation(1) 0 sysdevCheckSysdevFailed(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) dmtfGroups(1) eMylex5(9) eMylexRaidEventInformation(1) 0 systemDeviceCheckSystemDeviceFailed(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) dmtfGroups(1) eMylex5(9) eMylexRaidEventInformation(1) 0 fCArrayAssistant33(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) dmtfGroups(1) eMylex5(9) eMylexRaidEventInformation(1) 0 sysdevCheckSysdevFailed(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) eMylex4(1) tMylexRaidEventInformation(9) eMylexRaidEventInformation(1) 0 systemDeviceCheckSystemDeviceFailed(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) eMylex4(1) tMylexRaidEventInformation(9) eMylexRaidEventInformation(1) 0 fCArrayAssistant33(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) eMylex4(1) tMylexRaidEventInformation(9) eMylexRaidEventInformation(1) 0 sysdevCheckSysdevFailed(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) eMylex4(1) eMylex5(9) eMylexRaidEventInformation(1) 0 systemDeviceCheckSystemDeviceFailed(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) eMylex4(1) eMylex5(9) eMylexRaidEventInformation(1) 0 fCArrayAssistant33(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) dmtfComponents(1) eMylex4(1) eMylex5(9) eMylexRaidEventInformation(1) 0 sysdevCheckSysdevFailed(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) eMylex3(1) dmtfGroups(1) tMylexRaidEventInformation(9) eMylexRaidEventInformation(1) 0 systemDeviceCheckSystemDeviceFailed(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) eMylex3(1) dmtfGroups(1) tMylexRaidEventInformation(9) eMylexRaidEventInformation(1) 0 fCArrayAssistant33(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) eMylex3(1) dmtfGroups(1) tMylexRaidEventInformation(9) eMylexRaidEventInformation(1) 0 sysdevCheckSysdevFailed(132)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) mylex(1608) dmtfStd(1) eMylex3(1) dmtfGroups(1) eMylex5(9) eMylexRaidEventInformation(1) 0 systemDeviceCheckSystemDeviceFailed(132)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1608/1/1/1/9/1/0/132
  • /ISO/Identified-Organization/6/1/4/1/1608/1/1/1/9/1/0/132
  • /ISO/3/6/1/4/1/1608/1/1/1/9/1/0/132
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/dmtfGroups/tMylexRaidEventInformation/eMylexRaidEventInformation/0/systemDeviceCheckSystemDeviceFailed
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/dmtfGroups/tMylexRaidEventInformation/eMylexRaidEventInformation/0/fCArrayAssistant33
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/dmtfGroups/tMylexRaidEventInformation/eMylexRaidEventInformation/0/sysdevCheckSysdevFailed
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/dmtfGroups/eMylex5/eMylexRaidEventInformation/0/systemDeviceCheckSystemDeviceFailed
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/dmtfGroups/eMylex5/eMylexRaidEventInformation/0/fCArrayAssistant33
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/dmtfGroups/eMylex5/eMylexRaidEventInformation/0/sysdevCheckSysdevFailed
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/eMylex4/tMylexRaidEventInformation/eMylexRaidEventInformation/0/systemDeviceCheckSystemDeviceFailed
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/eMylex4/tMylexRaidEventInformation/eMylexRaidEventInformation/0/fCArrayAssistant33
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/eMylex4/tMylexRaidEventInformation/eMylexRaidEventInformation/0/sysdevCheckSysdevFailed
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/eMylex4/eMylex5/eMylexRaidEventInformation/0/systemDeviceCheckSystemDeviceFailed
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/eMylex4/eMylex5/eMylexRaidEventInformation/0/fCArrayAssistant33
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/dmtfComponents/eMylex4/eMylex5/eMylexRaidEventInformation/0/sysdevCheckSysdevFailed
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/eMylex3/dmtfGroups/tMylexRaidEventInformation/eMylexRaidEventInformation/0/systemDeviceCheckSystemDeviceFailed
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/eMylex3/dmtfGroups/tMylexRaidEventInformation/eMylexRaidEventInformation/0/fCArrayAssistant33
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/eMylex3/dmtfGroups/tMylexRaidEventInformation/eMylexRaidEventInformation/0/sysdevCheckSysdevFailed
  • /iso/identified-organization/dod/internet/private/enterprise/mylex/dmtfStd/eMylex3/dmtfGroups/eMylex5/eMylexRaidEventInformation/0/systemDeviceCheckSystemDeviceFailed
  • Additional combinations skipped.

Available source records contain 5 distinct definitions; some records may not include a definition.

Show 5 published definitions

sysdevCheckSysdevFailed · unspecified

sysdevCheckSysdevFailed    TRAP-TYPE
    ENTERPRISE  eMylexRaidEventInformation
    VARIABLES   {
	a9EventCode,
	a9ControllerNumber,
	a9LogicalDriveNumber,
	a9EventTimeStamp
    }
          DESCRIPTION
           "Consistency check on logical drive failed."
           --#SUMMARY  "[ctl: %d logdrv: %d :] Consistency check on logical drive failed." 
           --#ARGUMENTS {1,2}
           --#SEVERITY MAJOR
           --#TIMEINDEX 3
           --#STATE DEGRADED
           ::= 132

fCArrayAssistant33 · unspecified

fCArrayAssistant33	TRAP-TYPE
		ENTERPRISE  eMylexRaidEventInformation
		VARIABLES   {
			a9EventCode,
			a9ControllerNumber,
			a9LogicalDriveNumber,
			a9EventTimeStamp
		}
                 DESCRIPTION
                   "Consistency check on logical drive failed."
		   
                 --#SUMMARY "[Event %d ctl %d logdrv %d Time %d :] Consistency check on logical drive failed."
                 --#ARGUMENTS {0,1,2,3}
                 --#SEVERITY MAJOR
	         --#TIMEINDEX 3
                 --#STATE OPERATIONAL
                 ::= 132

sysdevCheckSysdevFailed · unspecified

sysdevCheckSysdevFailed    TRAP-TYPE
    ENTERPRISE  eMylexRaidEventInformation
    VARIABLES   {
	a9EventCode,
	a9ControllerNumber,
	a9LogicalDriveNumber,
	a9EventTimeStamp
    }
          DESCRIPTION
           "Consistency check / Make Data Consistent on logical drive failed."
           --#SUMMARY  "[ctl: %d logdrv: %d :] Consistency check / Make Data Consistent on logical drive failed." 
           --#ARGUMENTS {1,2}
           --#SEVERITY MAJOR
           --#TIMEINDEX 3
           --#STATE DEGRADED
           ::= 132

systemDeviceCheckSystemDeviceFailed · unspecified

systemDeviceCheckSystemDeviceFailed     TRAP-TYPE
		ENTERPRISE  eMylexRaidEventInformation
		VARIABLES   {
			a9EventCode,
			a9ControllerNumber,
			a9LogicalDriveNumber,
			a9EventTimeStamp
		}
		DESCRIPTION
		"Consistency check on logical drive failed."
		--#SUMMARY "[ctl %d logdrv %d :] Consistency check on
logical drive failed."
		--#ARGUMENTS {1,2}
		--#SEVERITY MAJOR
		--#TIMEINDEX 3
		--#STATE OPERATIONAL
		::= 132

systemDeviceCheckSystemDeviceFailed · unspecified

systemDeviceCheckSystemDeviceFailed     TRAP-TYPE
		ENTERPRISE  eMylexRaidEventInformation
		VARIABLES   {
			a9EventCode,
			a9ControllerNumber,
			a9LogicalDriveNumber,
			a9EventTimeStamp
		}
                 DESCRIPTION
                   "Consistency check on logical drive failed."
		   
                 --#SUMMARY "[ctl %d logdrv %d :] Consistency check on logical drive failed."
                 --#ARGUMENTS {1,2}
                 --#SEVERITY MAJOR
	         --#TIMEINDEX 3
                 --#STATE OPERATIONAL
                 ::= 132

Meaning

Descriptions

2 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 2

Consistency check / Make Data Consistent on logical drive failed.

Sources for this description

Reviewed vendor MIB copies in Fujitsu ServerView

See 1 matching source record

Evidence

Source records

5 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Circitor, MIBdepot4 records · 5 sources

Description 1

sysdevCheckSysdevFailed · unspecifiedCircitor, MIBdepot2 sources

Status in source: unspecified.

Names: sysdevCheckSysdevFailed

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sysdevCheckSysdevFailed",
    "TRAP-TYPE",
    "ENTERPRISE",
    "eMylexRaidEventInformation",
    "VARIABLES",
    "{",
    "a9EventCode",
    ",",
    "a9ControllerNumber",
    ",",
    "a9LogicalDriveNumber",
    ",",
    "a9EventTimeStamp",
    "}",
    "DESCRIPTION",
    "\"Consistency check on logical drive failed.\"",
    "::=",
    "132"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "eMylexRaidEventInformation"
      ]
    ],
    [
      "VarTypes",
      [
        "a9EventCode",
        "a9ControllerNumber",
        "a9LogicalDriveNumber",
        "a9EventTimeStamp"
      ]
    ],
    [
      "DESCRIPTION",
      "Consistency check on logical drive failed."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: MYLEXRAID-MIB

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter', 'enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download mlxraid.mib.txt
  • Preserved circitor archive

    Module: MYLEXRAID-MIB

    Same published definition (formatting differs; exact original is in the source file)

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['Counter', 'enterprises'], 'RFC1213-MIB': ['DisplayString']}
    · Download MYLEXRAID-MIB.mib
fCArrayAssistant33 · unspecifiedMIBdepot1 source

Status in source: unspecified.

Names: fCArrayAssistant33

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "fCArrayAssistant33",
    "TRAP-TYPE",
    "ENTERPRISE",
    "eMylexRaidEventInformation",
    "VARIABLES",
    "{",
    "a9EventCode",
    ",",
    "a9ControllerNumber",
    ",",
    "a9LogicalDriveNumber",
    ",",
    "a9EventTimeStamp",
    "}",
    "DESCRIPTION",
    "\"Consistency check on logical drive failed.\"",
    "::=",
    "132"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "eMylexRaidEventInformation"
      ]
    ],
    [
      "VarTypes",
      [
        "a9EventCode",
        "a9ControllerNumber",
        "a9LogicalDriveNumber",
        "a9EventTimeStamp"
      ]
    ],
    [
      "DESCRIPTION",
      "Consistency check on logical drive failed."
    ],
    null
  ]
}
systemDeviceCheckSystemDeviceFailed · unspecifiedMIBdepot1 source

Status in source: unspecified.

Names: systemDeviceCheckSystemDeviceFailed

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "systemDeviceCheckSystemDeviceFailed",
    "TRAP-TYPE",
    "ENTERPRISE",
    "eMylexRaidEventInformation",
    "VARIABLES",
    "{",
    "a9EventCode",
    ",",
    "a9ControllerNumber",
    ",",
    "a9LogicalDriveNumber",
    ",",
    "a9EventTimeStamp",
    "}",
    "DESCRIPTION",
    "\"Consistency check on logical drive failed.\"",
    "logical",
    "drive",
    "failed",
    ".",
    [
      "literal",
      "22"
    ],
    "::=",
    "132"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "eMylexRaidEventInformation"
      ]
    ],
    [
      "VarTypes",
      [
        "a9EventCode",
        "a9ControllerNumber",
        "a9LogicalDriveNumber",
        "a9EventTimeStamp"
      ]
    ],
    [
      "DESCRIPTION",
      "Consistency check on logical drive failed."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: MYLEXRAID-MIB

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC1155-SMI': ['Counter', 'enterprises'], 'RFC1213-MIB': ['DisplayString']}

    Source data warning: Potentially inaccurate historical source syntax: A proprietary --#SUMMARY comment wraps onto uncommented prose lines. Mask only those comment continuation lines in the parsing copy, preserving all native declarations, source bytes and notification numbers. The word problems. is an uncommented continuation of the preceding compiler-annotation explanation. Mask only that prose continuation; no declaration or numeric value changes. Earlier interpretations that combined a neighbour declaration with this name are superseded by the independently checked original assignments. Empty original descriptions stay empty; no new prose or numeric arc is invented.

    · Download mylexraid.mib.txt
systemDeviceCheckSystemDeviceFailed · unspecifiedMIBdepot1 source

Status in source: unspecified.

Names: systemDeviceCheckSystemDeviceFailed

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "systemDeviceCheckSystemDeviceFailed",
    "TRAP-TYPE",
    "ENTERPRISE",
    "eMylexRaidEventInformation",
    "VARIABLES",
    "{",
    "a9EventCode",
    ",",
    "a9ControllerNumber",
    ",",
    "a9LogicalDriveNumber",
    ",",
    "a9EventTimeStamp",
    "}",
    "DESCRIPTION",
    "\"Consistency check on logical drive failed.\"",
    "::=",
    "132"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "eMylexRaidEventInformation"
      ]
    ],
    [
      "VarTypes",
      [
        "a9EventCode",
        "a9ControllerNumber",
        "a9LogicalDriveNumber",
        "a9EventTimeStamp"
      ]
    ],
    [
      "DESCRIPTION",
      "Consistency check on logical drive failed."
    ],
    null
  ]
}
Records for description 2Reviewed vendor MIB copies in Fujitsu ServerView1 record · 1 source

Description 2

sysdevCheckSysdevFailed · unspecifiedReviewed vendor MIB copies in Fujitsu ServerView1 source

Status in source: unspecified.

Names: sysdevCheckSysdevFailed

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "sysdevCheckSysdevFailed",
    "TRAP-TYPE",
    "ENTERPRISE",
    "eMylexRaidEventInformation",
    "VARIABLES",
    "{",
    "a9EventCode",
    ",",
    "a9ControllerNumber",
    ",",
    "a9LogicalDriveNumber",
    ",",
    "a9EventTimeStamp",
    "}",
    "DESCRIPTION",
    "\"Consistency check / Make Data Consistent on logical drive failed.\"",
    "::=",
    "132"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "eMylexRaidEventInformation"
      ]
    ],
    [
      "VarTypes",
      [
        "a9EventCode",
        "a9ControllerNumber",
        "a9LogicalDriveNumber",
        "a9EventTimeStamp"
      ]
    ],
    [
      "DESCRIPTION",
      "Consistency check / Make Data Consistent on logical drive failed."
    ],
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1608)

Chandramouli Vytla

Siblings (377)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1608.1.1.1.9.1.0.105 physdevRbldMediumError00
1.3.6.1.4.1.1608.1.1.1.9.1.0.106 physdevRecCorrecting00
1.3.6.1.4.1.1608.1.1.1.9.1.0.107 physdevRecoverMediumError00
1.3.6.1.4.1.1608.1.1.1.9.1.0.108 physdevRedundantPathBroken00
1.3.6.1.4.1.1608.1.1.1.9.1.0.109 physdevRedundantPathRestored00
1.3.6.1.4.1.1608.1.1.1.9.1.0.110 physdevDedicatedSpareNoLongerUseful00
1.3.6.1.4.1.1608.1.1.1.9.1.0.111 physdevDedicatedSpareCreated00
1.3.6.1.4.1.1608.1.1.1.9.1.0.112 physdevDedicatedSpareDisabled00
1.3.6.1.4.1.1608.1.1.1.9.1.0.113 physdevDedicatedSpareNotUsefulForAll00
1.3.6.1.4.1.1608.1.1.1.9.1.0.114 physdevGlobalSpareCreated00
1.3.6.1.4.1.1608.1.1.1.9.1.0.115 physdevGlobalSpareDisabled00
1.3.6.1.4.1.1608.1.1.1.9.1.0.116 physdevGlobalSpareNotCoveringAll00
1.3.6.1.4.1.1608.1.1.1.9.1.0.117 physdevFormatComplete00
1.3.6.1.4.1.1608.1.1.1.9.1.0.118 physdevFormatStarted00
1.3.6.1.4.1.1608.1.1.1.9.1.0.119 physdevTooSmallForAutoRbld00
1.3.6.1.4.1.1608.1.1.1.9.1.0.120 physdevBbmLog80PercentFull00
1.3.6.1.4.1.1608.1.1.1.9.1.0.121 physdevBbmLogFull00
1.3.6.1.4.1.1608.1.1.1.9.1.0.126 physdevMediaerrorCorrected00
1.3.6.1.4.1.1608.1.1.1.9.1.0.127 sysdevCheckDoneWithError00
1.3.6.1.4.1.1608.1.1.1.9.1.0.128 systemDeviceCheckStarted, fCArrayAssistant29, sysdevCheckStart00
1.3.6.1.4.1.1608.1.1.1.9.1.0.129 systemDeviceCheckDone, fCArrayAssistant30, sysdevCheckDone00
1.3.6.1.4.1.1608.1.1.1.9.1.0.130 systemDeviceCheckCancelled, fCArrayAssistant31, sysdevCheckCanceled00
1.3.6.1.4.1.1608.1.1.1.9.1.0.131 systemDeviceCheckError, fCArrayAssistant32, sysdevCheckError00
1.3.6.1.4.1.1608.1.1.1.9.1.0.133 systemDeviceCheckPhysicalDeviceFailed, fCArrayAssistant34, sysdevCheckPhysdevFailed00
1.3.6.1.4.1.1608.1.1.1.9.1.0.134 systemDeviceOffline, fCArrayAssistant35, sysdevOffline00
1.3.6.1.4.1.1608.1.1.1.9.1.0.135 systemDeviceCritical, fCArrayAssistant36, sysdevCritical00
1.3.6.1.4.1.1608.1.1.1.9.1.0.136 systemDeviceOnline, fCArrayAssistant37, sysdevOnline00
1.3.6.1.4.1.1608.1.1.1.9.1.0.137 systemDeviceAutoRebuildStarted, fCArrayAssistant38, sysdevAutoRebuildStart00
1.3.6.1.4.1.1608.1.1.1.9.1.0.138 systemDeviceManualRebuildStarted, fCArrayAssistant39, sysdevManualRebuildStart00
1.3.6.1.4.1.1608.1.1.1.9.1.0.139 systemDeviceRebuildDone, fCArrayAssistant40, sysdevRebuildDone00
1.3.6.1.4.1.1608.1.1.1.9.1.0.140 systemDeviceRebuildCancelled, fCArrayAssistant41, sysdevRebuildCanceled00
1.3.6.1.4.1.1608.1.1.1.9.1.0.141 systemDeviceRebuildError, fCArrayAssistant42, sysdevRebuildError00
1.3.6.1.4.1.1608.1.1.1.9.1.0.142 systemDeviceRebuildNewDeviceFailed, fCArrayAssistant43, sysdevRebuildNewdevFailed00
1.3.6.1.4.1.1608.1.1.1.9.1.0.143 systemDeviceRebuildSystemDeviceFailed, fCArrayAssistant44, sysdevRebuildSysdevFailed00
1.3.6.1.4.1.1608.1.1.1.9.1.0.144 systemDeviceInitializationStarted, fCArrayAssistant45, sysdevInitStarted00
1.3.6.1.4.1.1608.1.1.1.9.1.0.145 systemDeviceInitializationDone, fCArrayAssistant46, sysdevInitDone00
1.3.6.1.4.1.1608.1.1.1.9.1.0.146 systemDeviceInitializationCanceled, fCArrayAssistant47, sysdevInitCanceled00
1.3.6.1.4.1.1608.1.1.1.9.1.0.147 systemDeviceInitializationFailed, fCArrayAssistant48, sysdevInitFailed00
1.3.6.1.4.1.1608.1.1.1.9.1.0.148 systemDeviceFound, fCArrayAssistant49, sysdevFound00
1.3.6.1.4.1.1608.1.1.1.9.1.0.149 systemDeviceGone, fCArrayAssistant50, sysdevGone00
1.3.6.1.4.1.1608.1.1.1.9.1.0.150 systemDeviceExpandCapacityStarted, fCArrayAssistant51, sysdevExpandcapacityStart00
1.3.6.1.4.1.1608.1.1.1.9.1.0.151 systemDeviceExpandCapacityDone, fCArrayAssistant52, sysdevExpandcapacityDone00
1.3.6.1.4.1.1608.1.1.1.9.1.0.152 systemDeviceExpandCapacityError, fCArrayAssistant53, sysdevExpandcapacityError00
1.3.6.1.4.1.1608.1.1.1.9.1.0.153 systemDeviceBadBlock, fCArrayAssistant54, sysdevBadblock00
1.3.6.1.4.1.1608.1.1.1.9.1.0.154 systemDeviceSizeChanged, fCArrayAssistant55, sysdevSizechanged00
1.3.6.1.4.1.1608.1.1.1.9.1.0.155 systemDeviceTypeChanged, fCArrayAssistant56, sysdevTypechanged00
1.3.6.1.4.1.1608.1.1.1.9.1.0.156 systemDeviceBadDataBlocksFound, fCArrayAssistant57, sysdevBaddatablock00
1.3.6.1.4.1.1608.1.1.1.9.1.0.157 sysdevWrLunMap, systemDeviceWriteLUNMap00
1.3.6.1.4.1.1608.1.1.1.9.1.0.158 sysdevDatareadFromBlockInBdt, systemDeviceReadfromBDT00
1.3.6.1.4.1.1608.1.1.1.9.1.0.159 sysdevDataForBlockLost00