Description 1
Cache ECC Error.
OID reference
1.3.6.1.4.1.1608.1.1.1.9.1.0.414
Cache ECC Error.
Identification
{1 3 6 1 4 1 1608 1 1 1 9 1 0 414}
Available source records contain 2 distinct definitions; some records may not include a definition.
adapterCacheECCError TRAP-TYPE
ENTERPRISE eMylexRaidEventInformation
VARIABLES {
a9EventCode,
a9ControllerNumber,
a9EventTimeStamp
}
DESCRIPTION
"Cache ECC Error."
--#SUMMARY "[ctl %d :] Cache ECC Error."
--#ARGUMENTS {1}
--#SEVERITY CRITICAL
--#TIMEINDEX 2
--#STATE DEGRADED
::= 414ctldevSoftEccCorrected TRAP-TYPE
ENTERPRISE eMylexRaidEventInformation
VARIABLES {
a9EventCode,
a9ControllerNumber,
a9EventTimeStamp
}
DESCRIPTION
"Soft ECC error corrected."
--#SUMMARY "[ctl: %d :] Soft ECC error corrected."
--#ARGUMENTS {1}
--#SEVERITY MAJOR
--#TIMEINDEX 2
--#STATE DEGRADED
::= 414
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Cache ECC Error.
Description 2
Soft ECC error corrected.
CircitorReviewed vendor MIB copies in Fujitsu ServerViewMIBdepot
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: unspecified.
Names: adapterCacheECCError
Module: MYLEXRAID-MIB
See published definition above
Source data warning: Potentially inaccurate historical source syntax: A proprietary --#SUMMARY comment wraps onto uncommented prose lines. Mask only those comment continuation lines in the parsing copy, preserving all native declarations, source bytes and notification numbers. The word problems. is an uncommented continuation of the preceding compiler-annotation explanation. Mask only that prose continuation; no declaration or numeric value changes. Earlier interpretations that combined a neighbour declaration with this name are superseded by the independently checked original assignments. Empty original descriptions stay empty; no new prose or numeric arc is invented.
· Download mylexraid.mib.txtStatus in source: unspecified.
Names: ctldevSoftEccCorrected
Module: MYLEXRAID-MIB
Same published definition (formatting differs; exact original is in the source file)
Source data warning: MIB copy distributed by Fujitsu in its ServerView package. The original vendor distribution and applicability to a particular device or firmware have not been independently confirmed; consult the named file and IANA enterprise registration.
· Download ServerView MIB copy — Mlxraid.mib (saved edition 1)Module: MYLEXRAID-MIB
See published definition above
· Download mlxraid.mib.txtRegistration