A string that identifies the EVC. It should be unique in the Maintenance Domain (i.e., in the managed network) Used as MEG ID field in OAM messages.
Sources for this description
Netdisco MIB archive copiesRAD MIB copies (Observium Community)
OID reference
1.3.6.1.4.1.164.6.3.7.1.5
A string that identifies the EVC. It should be unique in the Maintenance Domain (i.e., in the managed network) Used as MEG ID field in OAM messages.
Identification
{1 3 6 1 4 1 164 6 3 7 1 5}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
evcCosEvcName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A string that identifies the EVC. It should be unique
in the Maintenance Domain (i.e., in the managed network)
Used as MEG ID field in OAM messages."
::= {evcCosEntry 5}evcCosEvcName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A string that identifies the EVC. It should be unique
in the Maintenance Domain (i.e., in the managed network)
Used as MEG ID field in OAM messages."
::= {evcCosEntry 5}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
A string that identifies the EVC. It should be unique in the Maintenance Domain (i.e., in the managed network) Used as MEG ID field in OAM messages.
Netdisco MIB archive copiesRAD MIB copies (Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: evcCosEvcName
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"evcCosEvcName",
"OBJECT-TYPE",
"SYNTAX",
"SnmpAdminString",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"A string that identifies the EVC. It should be unique in the Maintenance Domain (i.e., in the managed network) Used as MEG ID field in OAM messages.\"",
"::=",
"{",
"evcCosEntry",
"5",
"}"
],
"syntax_tree": [
[
"row",
"SnmpAdminString"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A string that identifies the EVC. It should be unique in the Maintenance Domain (i.e., in the managed network) Used as MEG ID field in OAM messages."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. RAD support.
Module: RAD-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'ifAlias', 'ifIndex', 'InterfaceIndexOrZero', 'ifDescr'], 'APS-MIB': ['apsConfigEntry'], 'ATM-MIB': ['atmVplVpi', 'atmVclVpi', 'atmVclVci', 'aal5VccVpi', 'aal5VccVci', 'atmVpCrossConnectEntry', 'atmVcCrossConnectEntry', 'atmTrafficDescrParamEntry', 'atmVclEntry', 'aal5VccEntry'], 'DS1-MIB': ['dsx1LineStatus', 'dsx1LineStatusLastChange', 'dsx1CurrentIndex', 'dsx1LineIndex', 'dsx1IntervalIndex', 'dsx1IntervalNumber', 'dsx1LoopbackStatus', 'dsx1TotalIndex'], 'DS3-MIB': ['dsx3LineStatus', 'dsx3ConfigEntry', 'dsx3LoopbackStatus'], 'IMA-MIB': ['imaGroupIndex', 'imaLinkIfIndex', 'imaGroupFailureStatus'], 'MAU-MIB': ['rpMauMediaAvailable'], 'ATMF-CES': ['atmfCESCbrIndex', 'atmfCESConfEntry'], 'IPOA-MIB': ['ipoaLisIfMappingEntry'], 'ISDN-MIB': ['isdnSignalingEntry'], 'LLDP-MIB': ['LldpPortIdSubtype'], 'SNMPv2-TC': ['TimeStamp', 'TAddress', 'TEXTUAL-CONVENTION', 'DisplayString', 'RowStatus', 'DateAndTime', 'TruthValue', 'RowPointer'], 'ATM-TC-MIB': ['AtmTrafficDescrParamIndex'], 'BRIDGE-MIB': ['Timeout', 'BridgeId', 'dot1dBasePortEntry'], 'SNMPv2-SMI': ['Integer32', 'Counter32', 'TimeTicks', 'enterprises', 'IpAddress', 'Gauge32', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Counter64'], 'RFC1381-MIB': ['IfIndexType'], 'DIFFSERV-MIB': ['IndexIntegerNextFree', 'IndexInteger'], 'DOT3-OAM-MIB': ['dot3OamEntry', 'dot3OamOperStatus'], 'Q-BRIDGE-MIB': ['VlanIndex', 'PortList', 'dot1qVlanStaticEntry'], 'DS0BUNDLE-MIB': ['dsx0BundleEntry'], 'FRNETSERV-MIB': ['frPVCEndptDLCIIndex'], 'FDDI-SMT73-MIB': ['fddimibPORTPCMState'], 'IANAifType-MIB': ['IANAifType'], 'MPLS-TC-STD-MIB': ['MplsLabel', 'MplsTunnelIndex', 'MplsOwner', 'MplsLdpIdentifier', 'MplsLsrIdentifier'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount'], 'IEEE8021-CFM-MIB': ['dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber'], 'SNMP-REPEATER-MIB': ['rptrGroupOperStatus', 'rptrPortOperStatus'], 'MULTI-MEDIA-MIB-TC': ['MmTAddressTag', 'MmEndpointID', 'MmAliasAddress', 'MmH323EndpointType', 'MmGatekeeperID', 'MmAliasTag'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'DISMAN-SCHEDULE-MIB': ['schedEntry'], 'HDSL2-SHDSL-LINE-MIB': ['hdsl2ShdslEndpointCurrEntry', 'hdsl2ShdslInvIndex', 'hdsl2ShdslEndpointSide', 'hdsl2ShdslSpanConfProfileEntry'], 'FR-ATM-PVC-SERVICE-IWF-MIB': ['frAtmIwfConnectionEntry']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. RAD support.
Module: RAD-Services-MIB
See published definition above
{'IF-MIB': ['ifIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'RowStatus', 'MacAddress'], 'SNMPv2-SMI': ['Integer32', 'Counter32', 'IpAddress', 'Unsigned32', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'Counter64'], 'RAD-SMI-MIB': ['radGen'], 'Q-BRIDGE-MIB': ['VlanIdOrNone', 'VlanIdOrAnyOrNone'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber', 'InetAddressPrefixLength'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Vendor MIB copy from the Netdisco archive.
Module: RAD-MIB
{'IF-MIB': ['InterfaceIndex', 'ifAlias', 'ifIndex', 'ifDescr'], 'ATM-MIB': ['atmVplVpi', 'atmVclVpi', 'atmVclVci', 'atmVpCrossConnectEntry', 'atmVcCrossConnectEntry', 'atmTrafficDescrParamEntry'], 'DS1-MIB': ['dsx1CurrentIndex', 'dsx1IntervalIndex', 'dsx1IntervalNumber', 'dsx1LineIndex', 'dsx1TotalIndex', 'dsx1LineStatus', 'dsx1LineStatusLastChange', 'dsx1LoopbackStatus'], 'DS3-MIB': ['dsx3LineStatus', 'dsx3LoopbackStatus', 'dsx3ConfigEntry'], 'LLDP-MIB': ['LldpPortIdSubtype'], 'SNMPv2-TC': ['RowStatus', 'DateAndTime', 'TimeStamp', 'TEXTUAL-CONVENTION', 'DisplayString', 'MacAddress', 'RowPointer', 'TruthValue'], 'BRIDGE-MIB': ['Timeout', 'BridgeId', 'dot1dBasePortEntry'], 'SNMPv2-SMI': ['TimeTicks', 'enterprises', 'IpAddress', 'OBJECT-TYPE', 'Integer32', 'Counter32', 'Gauge32', 'OBJECT-IDENTITY', 'NOTIFICATION-TYPE', 'Unsigned32', 'Counter64'], 'DOT3-OAM-MIB': ['dot3OamEntry', 'dot3OamOperStatus'], 'Q-BRIDGE-MIB': ['VlanId', 'PortList', 'dot1qVlanStaticEntry'], 'IANAifType-MIB': ['IANAifType'], 'PerfHist-TC-MIB': ['PerfCurrentCount', 'PerfIntervalCount', 'PerfTotalCount'], 'IEEE8021-CFM-MIB': ['dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMepDbRMepIdentifier'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'DISMAN-SCHEDULE-MIB': ['schedEntry']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.164.6.3.7.1.1 | evcCosCnfgIdx | 0 | 0 | |
| 1.3.6.1.4.1.164.6.3.7.1.2 | evcCosEvcIdx | 0 | 0 | |
| 1.3.6.1.4.1.164.6.3.7.1.3 | evcCosRowStatus | 0 | 0 | |
| 1.3.6.1.4.1.164.6.3.7.1.6 | evcCosSpVlanId | 0 | 0 |