Status in source: current.
Names: erpsProfileGuardTimer
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"erpsProfileGuardTimer",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"(",
"10",
".",
".",
"2000",
")",
"UNITS",
[
"literal",
"226d696c6c697365636f6e647322"
],
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object is used to configure the period for the guard timer. This timer is required to prevent reception of outdated R-APS messages. Guard timer will be started on reception of local clear SF event. R-APS messages (except R-APS event messages) received during the running of the guard timer will be discarded.\"",
"DEFVAL",
"{",
"500",
"}",
"::=",
"{",
"erpsProfileEntry",
"4",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32",
[
"integerSubType",
[
[
10,
2000
]
]
]
],
[
"UNITS",
"milliseconds"
],
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object is used to configure the period for the guard timer. This timer is required to prevent reception of outdated R-APS messages. Guard timer will be started on reception of local clear SF event. R-APS messages (except R-APS event messages) received during the running of the guard timer will be discarded."
],
null,
null,
null,
[
"DEFVAL",
500
]
]
}