This object is used to specify the port interface that will be the first ring port of the physical ring.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.10.139.2.1.4.10.1.1.1.3
This object is used to specify the port interface that will be the first ring port of the physical ring.
Identification
{1 3 6 1 4 1 171 10 139 2 1 4 10 1 1 1 3}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In DLINK-DXS-1210-10TS-AX-MIB, the row index erpsInstanceId is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.171.10.139.2.1.4.10.1.1.1.3.<erpsInstanceId>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.171.10.139.2.1.4.10.1.1.1.3
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
erpsPort0 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to specify the port interface that
will be the first ring port of the physical ring."
::= { erpsInstanceEntry 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object is used to specify the port interface that will be the first ring port of the physical ring.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: erpsPort0
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"erpsPort0",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object is used to specify the port interface that will be the first ring port of the physical ring.\"",
"::=",
"{",
"erpsInstanceEntry",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object is used to specify the port interface that will be the first ring port of the physical ring."
],
null,
null,
null,
null
]
}Module: DLINK-DXS-1210-10TS-AX-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TimeStamp', 'DateAndTime', 'TimeInterval'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32', 'Counter64', 'Gauge32'], 'Q-BRIDGE-MIB': ['VlanId'], 'DIFFSERV-DSCP-TC': ['Dscp'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Registration