Description 1
This object is used to save Configuration.
OID reference
1.3.6.1.4.1.171.10.75.15.2.1.10
This object is used to save Configuration.
Identification
{1 3 6 1 4 1 171 10 75 15 2 1 10}
Definitions may combine these properties differently.
Numbers refer to source variants above. Each value is shown only for variants that define it.
| Value | Name | Source variants |
|---|---|---|
| 1 | true | 2 |
| 2 | false | 2 |
| 3 | config-1 | 2 |
| 4 | config-2 | 2 |
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
sysSave OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to save Configuration."
DEFVAL { false }
::= { companySystem 10 }sysSave OBJECT-TYPE
SYNTAX INTEGER {
true (1),
false (2),
config-1 (3),
config-2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to save Configuration , value 1 save config_1 ,
value 2 is not in process , value 3 is save config_1 and value 4 is save config_2."
DEFVAL { 1 }
::= { companySystem 10 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
This object is used to save Configuration.
Description 2
This object is used to save Configuration , value 1 save config_1 , value 2 is not in process , value 3 is save config_1 and value 4 is save config_2.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: sysSave
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sysSave",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object is used to save Configuration.\"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"companySystem",
"10",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object is used to save Configuration."
],
null,
null,
null,
[
"DEFVAL",
"false"
]
]
}Module: DES-1210-28ME_B2
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Status in source: current.
Names: sysSave
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sysSave",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"true",
"(",
"1",
")",
",",
"false",
"(",
"2",
")",
",",
"config-1",
"(",
"3",
")",
",",
"config-2",
"(",
"4",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This object is used to save Configuration , value 1 save config_1 , value 2 is not in process , value 3 is save config_1 and value 4 is save config_2.\"",
"DEFVAL",
"{",
"1",
"}",
"::=",
"{",
"companySystem",
"10",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"true",
1
],
[
"false",
2
],
[
"config-1",
3
],
[
"config-2",
4
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object is used to save Configuration , value 1 save config_1 , value 2 is not in process , value 3 is save config_1 and value 4 is save config_2."
],
null,
null,
null,
[
"DEFVAL",
1
]
]
}Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DES-1210-28MEbx
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DES-1210-28ME-B2
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Module: DES-1210-28ME-B2
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Registration