Description 1
Cable diagnostics pair 1 test result.
OID reference
1.3.6.1.4.1.171.10.75.15.2.35.2
Cable diagnostics pair 1 test result.
Identification
{1 3 6 1 4 1 171 10 75 15 2 35 2}
Definitions may combine these properties differently.
Numbers refer to source variants above. Each value is shown only for variants that define it.
| Value | Name | Source variants |
|---|---|---|
| 0 | ok | 1 |
| 1 | open | 1 |
| 2 | short | 1 |
| 5 | notAvailable | 1 |
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
cableDiagPair1TestResult OBJECT-TYPE
SYNTAX INTEGER {
ok (0),
open (1),
short (2),
notAvailable (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cable diagnostics pair 1 test result."
::= {companyCableDiagnostic 2 }autoCableDiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF AutoCableDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"When detecting a port linkdown, system will execute cable diagnostic function on the port,
and then send the trap that includes test result."
::= {companyCableDiagnostic 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Description 1
Cable diagnostics pair 1 test result.
Description 2
When detecting a port linkdown, system will execute cable diagnostic function on the port, and then send the trap that includes test result.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cableDiagPair1TestResult
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cableDiagPair1TestResult",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"ok",
"(",
"0",
")",
",",
"open",
"(",
"1",
")",
",",
"short",
"(",
"2",
")",
",",
"notAvailable",
"(",
"5",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Cable diagnostics pair 1 test result.\"",
"::=",
"{",
"companyCableDiagnostic",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"ok",
0
],
[
"open",
1
],
[
"short",
2
],
[
"notAvailable",
5
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Cable diagnostics pair 1 test result."
],
null,
null,
null,
null
]
}Module: DES-1210-28ME_B2
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Status in source: current.
Names: autoCableDiagTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"autoCableDiagTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"AutoCableDiagEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"When detecting a port linkdown, system will execute cable diagnostic function on the port, and then send the trap that includes test result.\"",
"::=",
"{",
"companyCableDiagnostic",
"2",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"AutoCableDiagEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"When detecting a port linkdown, system will execute cable diagnostic function on the port, and then send the trap that includes test result."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DES-1210-28ME-B2
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Related source files and packages:
Module: DES-1210-28ME-B2
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.10.75.15.2.35.2.1 | autoCableDiagEntry | 2 | 2 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.10.75.15.2.35.1 | cableDiagTriggerIndex, cableDiagTable | 1 | 14 | |
| 1.3.6.1.4.1.171.10.75.15.2.35.3 | cableDiagPair1FaultDistance | 0 | 0 | |
| 1.3.6.1.4.1.171.10.75.15.2.35.4 | cableDiagPair2TestResult | 0 | 0 | |
| 1.3.6.1.4.1.171.10.75.15.2.35.5 | cableDiagPair2FaultDistance | 0 | 0 | |
| 1.3.6.1.4.1.171.10.75.15.2.35.6 | cableDiagPair3TestResult | 0 | 0 | |
| 1.3.6.1.4.1.171.10.75.15.2.35.7 | cableDiagPair3FaultDistance | 0 | 0 | |
| 1.3.6.1.4.1.171.10.75.15.2.35.8 | cableDiagPair4TestResult | 0 | 0 | |
| 1.3.6.1.4.1.171.10.75.15.2.35.9 | cableDiagPair4FaultDistance | 0 | 0 | |
| 1.3.6.1.4.1.171.10.75.15.2.35.10 | cableDiagLengthinRange | 0 | 0 |