Status in source: current.
Names: rmonAlarmRisingThreshold
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rmonAlarmRisingThreshold",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is greater than or equal to this threshold and the associated alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3). After a rising event is generated, another such event will not be generated until the sampled value falls below this threshold and reaches the alarmFallingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid(1).\"",
"::=",
"{",
"rmonAlarmEntry",
"5",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is greater than or equal to this threshold and the associated alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3). After a rising event is generated, another such event will not be generated until the sampled value falls below this threshold and reaches the alarmFallingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid(1)."
],
null,
null,
null,
null
]
}
- D-Link official switch MIBs
· Publisher's source file: DGS-1210-20-BX-3_10_008.mib
Module: DGS-1210-20_BX
See published definition above
Module imports
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'INET-ADDRESS-MIB': ['InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}
· Download DGS-1210-20-BX-3_10_008.mib
Related source files and packages:
Same file in DGS-1210-20-BX-3_10_008.zip.
- D-Link MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
D-Link support.
Module: DGS-1210-20_BX
Same published definition
Module imports
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'INET-ADDRESS-MIB': ['InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}
· Download DGS-1210-20_BX
Related source files and packages: