OID reference

powerStatus

1.3.6.1.4.1.171.10.76.31.2.109.1.1.2

Description

Indicates status of the power lowVoltage : The voltage of the power unit is too low. overCurrent : The current of the power unit is too high. working : The power unit is working normally. fail : The power unit has failed. connect : The power unit is connected but not powered on. disconnect : The power unit is not conn…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.171.10.76.31.2.109.1.1 (powerEntry)
Node code
2
Node name
powerStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.171.10.76.31.2.109.1.1.2
URN notation
urn:oid:1.3.6.1.4.1.171.10.76.31.2.109.1.1.2
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 171 10 76 31 2 109 1 1 2}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-products(10) dlink-DGS1210SeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) products(10) dlink-DGS1210SeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsGponMIB(10) dlink-DGS1210SeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsGponMIB(10) dlink-DGS12XXSeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsGponMIB(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-products(10) dlink-DGS1210SeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) products(10) dlink-DGS1210SeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) nmsGponMIB(10) dlink-DGS1210SeriesProd(76) dgs-1210-20me(31) dgs-1210-20mebx(2) companyEquipmentGroup(109) powerTable(1) powerEntry(1) powerStatus(2)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/171/10/76/31/2/109/1/1/2
  • /ISO/Identified-Organization/6/1/4/1/171/10/76/31/2/109/1/1/2
  • /ISO/3/6/1/4/1/171/10/76/31/2/109/1/1/2
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-DGS1210SeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-DGS12XXSeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-DGS12XXTSeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-GE_Smart_Switch/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-DGS1210SeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-DGS12XXSeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-DGS12XXTSeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-GE_Smart_Switch/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-DGS1210SeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-DGS12XXSeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-DGS12XXTSeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-GE_Smart_Switch/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-DGS1210SeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-DGS12XXSeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-DGS12XXTSeriesProd/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-GE_Smart_Switch/dgs-1210-20me/dgs-1210-20mebx/companyEquipmentGroup/powerTable/powerEntry/powerStatus
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

ValueName
1other
2lowVoltage
3overCurrent
4working
5fail
6connect
7disconnect
8charging

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In DGS-1210-20ME-BX, the row index powerID is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.171.10.76.31.2.109.1.1.2.<powerID>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.171.10.76.31.2.109.1.1.2

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

powerStatus OBJECT-TYPE
           SYNTAX  INTEGER {
              other(1),
              lowVoltage(2),
              overCurrent(3),
              working(4),
              fail(5),
              connect(6),
              disconnect(7),
              charging(8)
     }
        MAX-ACCESS  read-only
        STATUS current
        DESCRIPTION
            "Indicates status of the power 
            lowVoltage : The voltage of the power unit is too low.
            overCurrent : The current of the power unit is too high.
            working : The power unit is working normally.
            fail : The power unit has failed.
            connect : The power unit is connected but not powered on.
            disconnect : The power unit is not connected."
        ::= { powerEntry 2 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Indicates status of the power lowVoltage : The voltage of the power unit is too low. overCurrent : The current of the power unit is too high. working : The power unit is working normally. fail : The power unit has failed. connect : The power unit is connected but not powered on. disconnect : The power unit is not connected.

Sources for this description

D-Link official switch MIBs

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1D-Link official switch MIBs1 record · 1 source

Description 1

powerStatus · currentD-Link official switch MIBs1 source

Status in source: current.

Names: powerStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "powerStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "other",
    "(",
    "1",
    ")",
    ",",
    "lowVoltage",
    "(",
    "2",
    ")",
    ",",
    "overCurrent",
    "(",
    "3",
    ")",
    ",",
    "working",
    "(",
    "4",
    ")",
    ",",
    "fail",
    "(",
    "5",
    ")",
    ",",
    "connect",
    "(",
    "6",
    ")",
    ",",
    "disconnect",
    "(",
    "7",
    ")",
    ",",
    "charging",
    "(",
    "8",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Indicates status of the power lowVoltage : The voltage of the power unit is too low. overCurrent : The current of the power unit is too high. working : The power unit is working normally. fail : The power unit has failed. connect : The power unit is connected but not powered on. disconnect : The power unit is not connected.\"",
    "::=",
    "{",
    "powerEntry",
    "2",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "other",
            1
          ],
          [
            "lowVoltage",
            2
          ],
          [
            "overCurrent",
            3
          ],
          [
            "working",
            4
          ],
          [
            "fail",
            5
          ],
          [
            "connect",
            6
          ],
          [
            "disconnect",
            7
          ],
          [
            "charging",
            8
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Indicates status of the power lowVoltage : The voltage of the power unit is too low. overCurrent : The current of the power unit is too high. working : The power unit is working normally. fail : The power unit has failed. connect : The power unit is connected but not powered on. disconnect : The power unit is not connected."
    ],
    null,
    null,
    null,
    null
  ]
}
  • D-Link official switch MIBs · Publisher's source file: DGS-1210-20ME-BX-7-03-001.mib

    Module: DGS-1210-20ME-BX

    See published definition above

    Module imports
    {'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TimeInterval', 'TimeStamp', 'TDomain', 'TAddress', 'DisplayString', 'RowPointer'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}
    · Download DGS-1210-20ME-BX-7-03-001.mib

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.171)

Henry P. Nagai

Siblings (1)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.171.10.76.31.2.109.1.1.1 powerID00