A MEP has a persistent defect condition. A notification (fault alarm) is sent to the management entity with the OID of the MEP that has detected the fault. Whenever a MEP has a persistent defect, it may or may not generate a Fault Alarm to warn the system administrator of the problem, as controlled by the MEP Fault Notification Generator State Machine and associated Managed Objects. Only the highest-priority defect, as shown in Table 20-1, is reported in the Fault Alarm. If a defect with a higher priority is raised after a Fault Alarm has been issued, another Fault Alarm is issued. The management entity receiving the notification can identify the system from the network source address of the notification, and can identify the MEP reporting the defect by the indices in the OID of the dot1agCfmMepHighestPrDefect variable in the notification: dot1agCfmMdIndex - Also the index of the MEP's Maintenance Domain table entry (dot1agCfmMdTable). dot1agCfmMaIndex - Also an index (with the MD table index) of the MEP's Maintenance Association network table entry (dot1agCfmMaNetTable), and (with the MD table index and component ID) of the MEP's MA component table entry (dot1agCfmMaCompTable). dot1agCfmMepIdentifier - MEP Identifier and final index into the MEP table (dot1agCfmMepTable).
OID reference
cfmFaultAlarm
1.3.6.1.4.1.171.10.76.36.2.110.16.0.5
Description
A MEP has a persistent defect condition. A notification (fault alarm) is sent to the management entity with the OID of the MEP that has detected the fault. Whenever a MEP has a persistent defect, it may or may not generate a Fault Alarm to warn the system administrator of the problem, as controlled by the MEP Fault No…
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.171.10.76.36.2.110.16.0 (cfmNotifyPrefix)
- Node code
- 5
- Node name
- cfmFaultAlarm
- Category
- SNMP notification
- Numeric OID
- 1.3.6.1.4.1.171.10.76.36.2.110.16.0.5
- URN notation
- urn:oid:1.3.6.1.4.1.171.10.76.36.2.110.16.0.5
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 171 10 76 36 2 110 16 0 5}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-products(10) dlink-DGS1210SeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) products(10) dlink-DGS1210SeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsGponMIB(10) dlink-DGS1210SeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsGponMIB(10) dlink-DGS12XXSeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsGponMIB(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-products(10) dlink-DGS1210SeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) products(10) dlink-DGS1210SeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) nmsGponMIB(10) dlink-DGS1210SeriesProd(76) dgs-1210-52pme(36) dgs-1210-52pmebx(2) companyCFMGroup(110) cfmNotify(16) cfmNotifyPrefix(0) cfmFaultAlarm(5)}
- Additional combinations skipped.
- OID-IRI notation
- /1/3/6/1/4/1/171/10/76/36/2/110/16/0/5
- /ISO/Identified-Organization/6/1/4/1/171/10/76/36/2/110/16/0/5
- /ISO/3/6/1/4/1/171/10/76/36/2/110/16/0/5
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-DGS1210SeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-DGS12XXSeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-DGS12XXTSeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-GE_Smart_Switch/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-DGS1210SeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-DGS12XXSeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-DGS12XXTSeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-GE_Smart_Switch/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-DGS1210SeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-DGS12XXSeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-DGS12XXTSeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-GE_Smart_Switch/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-DGS1210SeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-DGS12XXSeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-DGS12XXTSeriesProd/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-GE_Smart_Switch/dgs-1210-52pme/dgs-1210-52pmebx/companyCFMGroup/cfmNotify/cfmNotifyPrefix/cfmFaultAlarm
- Additional combinations skipped.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
cfmFaultAlarm NOTIFICATION-TYPE
OBJECTS {
cfmMepHighestPrDefect }
STATUS current
DESCRIPTION
"A MEP has a persistent defect condition. A notification
(fault alarm) is sent to the management entity with the OID
of the MEP that has detected the fault.
Whenever a MEP has a persistent defect,
it may or may not generate a Fault Alarm to warn the system
administrator of the problem, as controlled by the MEP
Fault Notification Generator State Machine and associated
Managed Objects. Only the highest-priority defect, as shown
in Table 20-1, is reported in the Fault Alarm.
If a defect with a higher priority is raised after a Fault
Alarm has been issued, another Fault Alarm is issued.
The management entity receiving the notification can identify
the system from the network source address of the
notification, and can identify the MEP reporting the defect
by the indices in the OID of the dot1agCfmMepHighestPrDefect
variable in the notification:
dot1agCfmMdIndex - Also the index of the MEP's
Maintenance Domain table entry
(dot1agCfmMdTable).
dot1agCfmMaIndex - Also an index (with the MD table index)
of the MEP's Maintenance Association
network table entry
(dot1agCfmMaNetTable), and (with the MD
table index and component ID) of the
MEP's MA component table entry
(dot1agCfmMaCompTable).
dot1agCfmMepIdentifier - MEP Identifier and final index
into the MEP table (dot1agCfmMepTable).
"
::= { cfmNotifyPrefix 5 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Records for description 1D-Link official switch MIBs
cfmFaultAlarm · currentD-Link official switch MIBs
Status in source: current.
Names: cfmFaultAlarm
Technical details
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"cfmFaultAlarm",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"cfmMepHighestPrDefect",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"A MEP has a persistent defect condition. A notification (fault alarm) is sent to the management entity with the OID of the MEP that has detected the fault. Whenever a MEP has a persistent defect, it may or may not generate a Fault Alarm to warn the system administrator of the problem, as controlled by the MEP Fault Notification Generator State Machine and associated Managed Objects. Only the highest-priority defect, as shown in Table 20-1, is reported in the Fault Alarm. If a defect with a higher priority is raised after a Fault Alarm has been issued, another Fault Alarm is issued. The management entity receiving the notification can identify the system from the network source address of the notification, and can identify the MEP reporting the defect by the indices in the OID of the dot1agCfmMepHighestPrDefect variable in the notification: dot1agCfmMdIndex - Also the index of the MEP's Maintenance Domain table entry (dot1agCfmMdTable). dot1agCfmMaIndex - Also an index (with the MD table index) of the MEP's Maintenance Association network table entry (dot1agCfmMaNetTable), and (with the MD table index and component ID) of the MEP's MA component table entry (dot1agCfmMaCompTable). dot1agCfmMepIdentifier - MEP Identifier and final index into the MEP table (dot1agCfmMepTable). \"",
"::=",
"{",
"cfmNotifyPrefix",
"5",
"}"
],
"syntax_tree": [
[
"Objects",
[
"cfmMepHighestPrDefect"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A MEP has a persistent defect condition. A notification (fault alarm) is sent to the management entity with the OID of the MEP that has detected the fault. Whenever a MEP has a persistent defect, it may or may not generate a Fault Alarm to warn the system administrator of the problem, as controlled by the MEP Fault Notification Generator State Machine and associated Managed Objects. Only the highest-priority defect, as shown in Table 20-1, is reported in the Fault Alarm. If a defect with a higher priority is raised after a Fault Alarm has been issued, another Fault Alarm is issued. The management entity receiving the notification can identify the system from the network source address of the notification, and can identify the MEP reporting the defect by the indices in the OID of the dot1agCfmMepHighestPrDefect variable in the notification: dot1agCfmMdIndex - Also the index of the MEP's Maintenance Domain table entry (dot1agCfmMdTable). dot1agCfmMaIndex - Also an index (with the MD table index) of the MEP's Maintenance Association network table entry (dot1agCfmMaNetTable), and (with the MD table index and component ID) of the MEP's MA component table entry (dot1agCfmMaCompTable). dot1agCfmMepIdentifier - MEP Identifier and final index into the MEP table (dot1agCfmMepTable)."
],
null
]
}- D-Link official switch MIBs
· Publisher's source file: DGS-1210-52PME-BX-7-02-020.mib
Module: DGS-1210-52PME-BX
See published definition above
· Download DGS-1210-52PME-BX-7-02-020.mibModule imports
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TimeInterval', 'TimeStamp', 'TDomain', 'TAddress', 'DisplayString', 'RowPointer'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.171)
Siblings (4)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.10.76.36.2.110.16.0.1 | cfmAISOccurred | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.36.2.110.16.0.2 | cfmAISCleared | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.36.2.110.16.0.3 | cfmLockOccurred | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.36.2.110.16.0.4 | cfmLockCleared | 0 | 0 |