OID reference

cfmMepTransmitLbmDestMacAddress

1.3.6.1.4.1.171.10.76.37.2.110.8.1.23

Description

The Target MAC Address Field to be transmitted: A unicast destination MAC address. This address will be used if the value of the column cfmMepTransmitLbmDestIsMepId is 'false'.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.171.10.76.37.2.110.8.1 (cfmMepEntry)
Node code
23
Node name
cfmMepTransmitLbmDestMacAddress
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.171.10.76.37.2.110.8.1.23
URN notation
urn:oid:1.3.6.1.4.1.171.10.76.37.2.110.8.1.23
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 171 10 76 37 2 110 8 1 23}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-products(10) dlink-DGS1210SeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) products(10) dlink-DGS1210SeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsGponMIB(10) dlink-DGS1210SeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsGponMIB(10) dlink-DGS12XXSeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsGponMIB(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-products(10) dlink-DGS1210SeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) products(10) dlink-DGS1210SeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) products(10) dlink-DGS12XXSeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) products(10) dlink-DGS12XXTSeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) nmsGponMIB(10) dlink-DGS1210SeriesProd(76) dgs-1210-52mpme(37) dgs-1210-52mpmebx(2) companyCFMGroup(110) cfmMepTable(8) cfmMepEntry(1) cfmMepTransmitLbmDestMacAddress(23)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/171/10/76/37/2/110/8/1/23
  • /ISO/Identified-Organization/6/1/4/1/171/10/76/37/2/110/8/1/23
  • /ISO/3/6/1/4/1/171/10/76/37/2/110/8/1/23
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-DGS1210SeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-DGS12XXSeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-DGS12XXTSeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/dlink-GE_Smart_Switch/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-DGS1210SeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-DGS12XXSeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-DGS12XXTSeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/products/dlink-GE_Smart_Switch/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-DGS1210SeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-DGS12XXSeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-DGS12XXTSeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/dlink-GE_Smart_Switch/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-DGS1210SeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-DGS12XXSeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-DGS12XXTSeriesProd/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/dlink-GE_Smart_Switch/dgs-1210-52mpme/dgs-1210-52mpmebx/companyCFMGroup/cfmMepTable/cfmMepEntry/cfmMepTransmitLbmDestMacAddress
  • Additional combinations skipped.

SNMP properties

Value type
MacAddress
Maximum access defined by MIB
read-create
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

cfmMepTransmitLbmDestMacAddress OBJECT-TYPE
    SYNTAX      MacAddress
    MAX-ACCESS  read-create
    STATUS      current
    DESCRIPTION
       "The Target MAC Address Field to be transmitted: A unicast
        destination MAC address.
        This address will be used if the value of the column
        cfmMepTransmitLbmDestIsMepId is 'false'.
       "
    REFERENCE
       "802.1ag clause 12.14.7.3.2:b"
    ::= { cfmMepEntry 23 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The Target MAC Address Field to be transmitted: A unicast destination MAC address. This address will be used if the value of the column cfmMepTransmitLbmDestIsMepId is 'false'.

Sources for this description

D-Link official switch MIBs

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1D-Link official switch MIBs1 record · 1 source

Description 1

cfmMepTransmitLbmDestMacAddress · currentD-Link official switch MIBs1 source

Status in source: current.

Names: cfmMepTransmitLbmDestMacAddress

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "cfmMepTransmitLbmDestMacAddress",
    "OBJECT-TYPE",
    "SYNTAX",
    "MacAddress",
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The Target MAC Address Field to be transmitted: A unicast destination MAC address. This address will be used if the value of the column cfmMepTransmitLbmDestIsMepId is 'false'. \"",
    "REFERENCE",
    "\"802.1ag clause 12.14.7.3.2:b\"",
    "::=",
    "{",
    "cfmMepEntry",
    "23",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "MacAddress"
    ],
    null,
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The Target MAC Address Field to be transmitted: A unicast destination MAC address. This address will be used if the value of the column cfmMepTransmitLbmDestIsMepId is 'false'."
    ],
    [
      "REFERENCE",
      "802.1ag clause 12.14.7.3.2:b"
    ],
    null,
    null,
    null
  ]
}
  • D-Link official switch MIBs · Publisher's source file: DGS-1210-52MPME-BX-7-02-020.mib

    Module: DGS-1210-52MPME-BX

    See published definition above

    Module imports
    {'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TimeInterval', 'TimeStamp', 'TDomain', 'TAddress', 'DisplayString', 'RowPointer'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}
    · Download DGS-1210-52MPME-BX-7-02-020.mib

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.171)

Henry P. Nagai

Siblings (55)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.171.10.76.37.2.110.8.1.1 cfmMepIdentifier00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.2 cfmMepIfIndex00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.3 cfmMepDirection00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.4 cfmMepPrimaryVid00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.5 cfmMepActive00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.6 cfmMepFngState00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.7 cfmMepCciEnabled00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.8 cfmMepCcmLtmPriority00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.9 cfmMepMacAddress00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.10 cfmMepLowPrDef00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.11 cfmMepFngAlarmTime00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.12 cfmMepFngResetTime00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.13 cfmMepHighestPrDefect00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.14 cfmMepCcmSequenceErrors00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.15 cfmMepCciSentCcms00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.16 cfmMepNextLbmTransId00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.17 cfmMepLbrIn00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.18 cfmMepLbrInOutOfOrder00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.19 cfmMepLtmNextSeqNumber00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.20 cfmMepUnexpLtrIn00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.21 cfmMepLbrOut00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.22 cfmMepTransmitLbmStatus00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.24 cfmMepTransmitLbmDestMepId00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.25 cfmMepTransmitLbmDestIsMepId00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.26 cfmMepTransmitLbmMessages00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.27 cfmMepTransmitLbmDataTlv00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.28 cfmMepTransmitLbmVlanPriority00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.29 cfmMepTransmitLbmResultOK00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.30 cfmMepTransmitLbmSeqNumber00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.31 cfmMepTransmitLtmStatus00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.32 cfmMepTransmitLtmFlags00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.33 cfmMepTransmitLtmTargetMacAddress00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.34 cfmMepTransmitLtmTargetMepId00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.35 cfmMepTransmitLtmTargetIsMepId00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.36 cfmMepTransmitLtmTtl00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.37 cfmMepTransmitLtmResult00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.38 cfmMepTransmitLtmSeqNumber00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.39 cfmMepCcmOffload00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.40 cfmMepName00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.41 cfmMepCciAisTx00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.42 cfmMepCciAisRx00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.43 cfmMepCciLckTx00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.44 cfmMepCciLckRx00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.45 cfmMepAisCapability00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.46 cfmMepAisCondition00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.47 cfmMepAisInterval00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.48 cfmMepAisPriority00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.49 cfmMepLckCapability00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.50 cfmMepLckCondition00
1.3.6.1.4.1.171.10.76.37.2.110.8.1.51 cfmMepLckInterval00