Identifies the number of CFM-PDUs discarded.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.10.76.43.1.110.12.16
Identifies the number of CFM-PDUs discarded.
Identification
{1 3 6 1 4 1 171 10 76 43 1 110 12 16}
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.171.10.76.43.1.110.12.16.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cfmDsrdCfmPduCount OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Identifies the number of CFM-PDUs discarded."
::= { cfmStatsTable 16 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Identifies the number of CFM-PDUs discarded.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cfmDsrdCfmPduCount
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cfmDsrdCfmPduCount",
"OBJECT-TYPE",
"SYNTAX",
"Unsigned32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Identifies the number of CFM-PDUs discarded.\"",
"::=",
"{",
"cfmStatsTable",
"16",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Unsigned32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Identifies the number of CFM-PDUs discarded."
],
null,
null,
null,
null
]
}Module: DGS-1210-28XME-BX
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TimeInterval', 'TimeStamp', 'TDomain', 'TAddress', 'DisplayString', 'RowPointer'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DGS-1210-28XME-BX
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TimeInterval', 'TimeStamp', 'TDomain', 'TAddress', 'DisplayString', 'RowPointer'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.10.76.43.1.110.12.1 | cfmTxCfmPduCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.2 | cfmTxCcmCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.3 | cfmTxLbmCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.4 | cfmTxLbrCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.5 | cfmTxLtmCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.6 | cfmTxLtrCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.7 | cfmTxFailedCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.8 | cfmRxCfmPduCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.9 | cfmRxCcmCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.10 | cfmRxLbmCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.11 | cfmRxLbrCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.12 | cfmRxLtmCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.13 | cfmRxLtrCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.14 | cfmRxBadCfmPduCount | 0 | 0 | |
| 1.3.6.1.4.1.171.10.76.43.1.110.12.15 | cfmFrwdCfmPduCount | 0 | 0 |