Indicates if MEP is in LCK condition. LCK condition occurs when it receives a LCK frame.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.10.76.43.1.110.8.1.50
Indicates if MEP is in LCK condition. LCK condition occurs when it receives a LCK frame.
Identification
{1 3 6 1 4 1 171 10 76 43 1 110 8 1 50}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
cfmMepLckCondition OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if MEP is in LCK condition.
LCK condition occurs when it receives a LCK frame.
"
DEFVAL { false }
::= { cfmMepEntry 50 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates if MEP is in LCK condition. LCK condition occurs when it receives a LCK frame.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: cfmMepLckCondition
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"cfmMepLckCondition",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates if MEP is in LCK condition. LCK condition occurs when it receives a LCK frame. \"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"cfmMepEntry",
"50",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates if MEP is in LCK condition. LCK condition occurs when it receives a LCK frame."
],
null,
null,
null,
[
"DEFVAL",
"false"
]
]
}Module: DGS-1210-28XME-BX
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TimeInterval', 'TimeStamp', 'TDomain', 'TAddress', 'DisplayString', 'RowPointer'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DGS-1210-28XME-BX
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TimeInterval', 'TimeStamp', 'TDomain', 'TAddress', 'DisplayString', 'RowPointer'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Related source files and packages:
Registration