To set SerialPort baud-rate configuration.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.10.76.44.1.1.21
To set SerialPort baud-rate configuration.
Identification
{1 3 6 1 4 1 171 10 76 44 1 1 21}
| Value | Name |
|---|---|
| 9600 | baudrate9600 |
| 19200 | baudrate19200 |
| 38400 | baudrate38400 |
| 115200 | baudrate115200 |
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.171.10.76.44.1.1.21.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
baudRateConfiguration OBJECT-TYPE
SYNTAX INTEGER {
baudrate9600(9600),
baudrate19200(19200),
baudrate38400(38400),
baudrate115200(115200)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To set SerialPort baud-rate configuration."
::= { companySystem 21 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
To set SerialPort baud-rate configuration.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: baudRateConfiguration
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"baudRateConfiguration",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"baudrate9600",
"(",
"9600",
")",
",",
"baudrate19200",
"(",
"19200",
")",
",",
"baudrate38400",
"(",
"38400",
")",
",",
"baudrate115200",
"(",
"115200",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"To set SerialPort baud-rate configuration.\"",
"::=",
"{",
"companySystem",
"21",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"baudrate9600",
9600
],
[
"baudrate19200",
19200
],
[
"baudrate38400",
38400
],
[
"baudrate115200",
115200
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"To set SerialPort baud-rate configuration."
],
null,
null,
null,
null
]
}Module: DGS-1210-12TSME-BX
See published definition above
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TimeInterval', 'TimeStamp', 'TDomain', 'TAddress', 'DisplayString', 'RowPointer'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DGS-1210-12TSME-BX
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32'], 'Q-BRIDGE-MIB': ['VlanId'], 'INET-ADDRESS-MIB': ['InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Related source files and packages:
Registration