Trap indicating that the backup unit was removed from the stack.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.10.94.89.89.0.188
Trap indicating that the backup unit was removed from the stack.
Identification
{1 3 6 1 4 1 171 10 94 89 89 0 188}
The displayed source records contain one distinct definition. Compare its source records.
rlStackBackupUnitRemoved NOTIFICATION-TYPE
OBJECTS { rndErrorDesc, rndErrorSeverity }
STATUS current
DESCRIPTION
"Trap indicating that the backup unit was removed from the stack."
::= { rndNotifications 188 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Trap indicating that the backup unit was removed from the stack.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlStackBackupUnitRemoved
{
"smi_kind": "NOTIFICATION-TYPE",
"definition": [
"rlStackBackupUnitRemoved",
"NOTIFICATION-TYPE",
"OBJECTS",
"{",
"rndErrorDesc",
",",
"rndErrorSeverity",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"Trap indicating that the backup unit was removed from the stack.\"",
"::=",
"{",
"rndNotifications",
"188",
"}"
],
"syntax_tree": [
[
"Objects",
[
"rndErrorDesc",
"rndErrorSeverity"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Trap indicating that the backup unit was removed from the stack."
],
null
]
}Module: RADLAN-Physicaldescription-MIB
See published definition above
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex', 'InterfaceIndex'], 'MAU-MIB': ['JackType'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'RowStatus'], 'RADLAN-MIB': ['rnd', 'rndNotifications'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'NOTIFICATION-TYPE'], 'ENTITY-SENSOR-MIB': ['EntitySensorStatus', 'EntitySensorValue'], 'RADLAN-HWENVIROMENT': ['RlEnvMonState'], 'RADLAN-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}Related source files and packages:
Module: DLINK-3100-Physicaldescription-MIB
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex', 'InterfaceIndex'], 'MAU-MIB': ['JackType'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'RowStatus'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'NOTIFICATION-TYPE'], 'DLINK-3100-MIB': ['rnd', 'rndNotifications'], 'ENTITY-SENSOR-MIB': ['EntitySensorStatus', 'EntitySensorValue'], 'DLINK-3100-HWENVIROMENT': ['RlEnvMonState'], 'DLINK-3100-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}Related source files and packages:
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DLINK-3100-Physicaldescription-MIB
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex', 'InterfaceIndex'], 'MAU-MIB': ['JackType'], 'SNMPv2-TC': ['DisplayString', 'PhysAddress', 'RowStatus'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'MODULE-IDENTITY', 'TimeTicks', 'NOTIFICATION-TYPE'], 'DLINK-3100-MIB': ['rnd', 'rndNotifications'], 'ENTITY-SENSOR-MIB': ['EntitySensorStatus', 'EntitySensorValue'], 'DLINK-3100-HWENVIROMENT': ['RlEnvMonState'], 'DLINK-3100-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}Related source files and packages:
Registration