The number of messages unable to be queued to the downstream side of the syslog device software for transmitting.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.10.94.89.89.82.1.1.2
The number of messages unable to be queued to the downstream side of the syslog device software for transmitting.
Identification
{1 3 6 1 4 1 171 10 94 89 89 82 1 1 2}
A counter is cumulative. To estimate a rate, subtract two readings and divide by the elapsed time; use the units stated in the MIB.
Counter values can wrap or reset. A decrease alone does not distinguish a wrap from a reset, and multiple wraps between readings cannot be recovered reliably. Check the device's discontinuity indicators when available.
Published counter width: 32 bits. SMIv2: Counter32 · Counter64
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.171.10.94.89.89.82.1.1.2.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
snmpSyslogDeviceMessagesDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of messages unable to be queued to
the downstream side of the syslog device software
for transmitting."
::= { snmpSyslogDevice 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The number of messages unable to be queued to the downstream side of the syslog device software for transmitting.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: snmpSyslogDeviceMessagesDropped
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"snmpSyslogDeviceMessagesDropped",
"OBJECT-TYPE",
"SYNTAX",
"Counter32",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The number of messages unable to be queued to the downstream side of the syslog device software for transmitting.\"",
"::=",
"{",
"snmpSyslogDevice",
"2",
"}"
],
"syntax_tree": [
[
"ApplicationSyntax",
"Counter32"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The number of messages unable to be queued to the downstream side of the syslog device software for transmitting."
],
null,
null,
null,
null
]
}Module: DRAFT-IETF-SYSLOG-DEVICE-MIB
See published definition above
{'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp'], 'RADLAN-MIB': ['rlSyslog'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'snmpModules'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Module: DRAFT-IETF-SYSLOG-DEVICE-MIB
{'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'snmpModules'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'DLINK-3100-MIB': ['rlSyslog'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DLINK-3100-SYSLOG-DEVICE-MIB
{'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'snmpModules'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'DLINK-3100-MIB': ['rlSyslog'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.10.94.89.89.82.1.1.1 | snmpSyslogDeviceMessages | 0 | 0 | |
| 1.3.6.1.4.1.171.10.94.89.89.82.1.1.3 | snmpSyslogDeviceLastMessageTime | 0 | 0 | |
| 1.3.6.1.4.1.171.10.94.89.89.82.1.1.4 | snmpSyslogDeviceControl | 0 | 0 |