Status in source: current.
Names: snmpSyslogCollectorSeverity
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"snmpSyslogCollectorSeverity",
"OBJECT-TYPE",
"SYNTAX",
"SyslogSeverity",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The maximum severity level of the messages that SHOULD be forwarded to the syslog collector. The higher the level, the lower the severity. If an entity only supports filtering based on a single severity level for all collectors then this may optionally be implemented read-only, in which case the current value of snmpSyslogCollectorDefaultSeverity will be used.\"",
"::=",
"{",
"snmpSyslogCollectorEntry",
"7",
"}"
],
"syntax_tree": [
[
"row",
"SyslogSeverity"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The maximum severity level of the messages that SHOULD be forwarded to the syslog collector. The higher the level, the lower the severity. If an entity only supports filtering based on a single severity level for all collectors then this may optionally be implemented read-only, in which case the current value of snmpSyslogCollectorDefaultSeverity will be used."
],
null,
null,
null,
null
]
}
- D-Link official switch MIBs
· Publisher's source file: Source package: DGS-3100_FW_3.00.43_MIB.zip
Module: DRAFT-IETF-SYSLOG-DEVICE-MIB
See published definition above
Module imports
{'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp'], 'RADLAN-MIB': ['rlSyslog'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'snmpModules'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
· Download draft-ietf-syslog-device-mib.mib
Related source files and packages:
- D-Link official switch MIBs
· Publisher's source file: Source package: DGS-3100_FW_3.50.23_MIB.zip
Module: DRAFT-IETF-SYSLOG-DEVICE-MIB
Same published definition
Module imports
{'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'snmpModules'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'DLINK-3100-MIB': ['rlSyslog'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
· Download draft-ietf-syslog-device-mib.mib
Related source files and packages:
Show more related files and packages
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
- D-Link MIB copies (LibreNMS/Observium Community)
· Publisher's source file: Source package: observium-community-latest.tar.gz
Vendor MIB copy from the Observium Community archive.
D-Link support.
Module: DLINK-3100-SYSLOG-DEVICE-MIB
Same published definition
Module imports
{'SNMPv2-TC': ['RowStatus', 'TEXTUAL-CONVENTION', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Gauge32', 'snmpModules'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'DLINK-3100-MIB': ['rlSyslog'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
· Download DLINK-3100-SYSLOG-DEVICE-MIB
Related source files and packages: