Error message as a result of failed copy action.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.10.94.89.89.87.4.1.18
Error message as a result of failed copy action.
Identification
{1 3 6 1 4 1 171 10 94 89 89 87 4 1 18}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
rlCopyHistoryErrorMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Error message as a result of failed copy action."
::= { rlCopyHistoryEntry 18 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Error message as a result of failed copy action.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: rlCopyHistoryErrorMessage
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rlCopyHistoryErrorMessage",
"OBJECT-TYPE",
"SYNTAX",
"DisplayString",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Error message as a result of failed copy action.\"",
"::=",
"{",
"rlCopyHistoryEntry",
"18",
"}"
],
"syntax_tree": [
[
"row",
"DisplayString"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Error message as a result of failed copy action."
],
null,
null,
null,
null
]
}Module: RADLAN-COPY-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus'], 'RADLAN-MIB': ['rnd', 'rndNotifications'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'Counter32', 'TimeTicks', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'RADLAN-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}Related source files and packages:
Module: DLINK-3100-COPY-MIB
{'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'Counter32', 'TimeTicks', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'DLINK-3100-MIB': ['rnd', 'rndNotifications'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'DLINK-3100-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}Related source files and packages:
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Same file in DGS-3100_series_FW_3.60.28_MIB.zip.
Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DLINK-3100-COPY-MIB
{'SNMPv2-TC': ['DisplayString', 'TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'Unsigned32', 'Counter32', 'TimeTicks', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE'], 'DLINK-3100-MIB': ['rnd', 'rndNotifications'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'DLINK-3100-DEVICEPARAMS-MIB': ['rndErrorDesc', 'rndErrorSeverity']}Related source files and packages:
Registration