This object displays whether an electrical source is normal or not.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.10.97.2.1.1.18.1.2
This object displays whether an electrical source is normal or not.
Identification
{1 3 6 1 4 1 171 10 97 2 1 1 18 1 2}
Definitions may combine these properties differently.
Numbers refer to source variants above. Each value is shown only for variants that define it. Notes below names come from selected MIB definitions.
| Value | Name and source notes | Source variants |
|---|---|---|
| 0 | abnormal | 1 |
| 1 | noexist no exist | 2 |
| 1 | normal | 1 |
| 2 | existnopower exist no power | 2 |
| 3 | existreadypower exist ready power | 2 |
| 4 | normal normal | 2 |
| 5 | powerbutabnormal power but abnormal | 2 |
| 6 | unknow unknow | 2 |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In MY-SYSTEM-MIB, the row index mySystemElectricalSourceIsNormalIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.171.10.97.2.1.1.18.1.2.<mySystemElectricalSourceIsNormalIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.171.10.97.2.1.1.18.1.2
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
mySystemElectricalSourceIsNormal OBJECT-TYPE
SYNTAX INTEGER {
abnormal (0),
normal (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object displays whether an electrical source is normal or not."
::= { mySystemElectricalSourceIsNormalEntry 2 }mySystemElectricalSourceIsNormal OBJECT-TYPE
SYNTAX INTEGER {
noexist (1), --no exist
existnopower (2), -- exist no power
existreadypower (3), --exist ready power
normal (4), --normal
powerbutabnormal (5), --power but abnormal
unknow (6) --unknow
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object displays whether an electrical source is normal or not."
::= { mySystemElectricalSourceIsNormalEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This object displays whether an electrical source is normal or not.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: mySystemElectricalSourceIsNormal
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mySystemElectricalSourceIsNormal",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"abnormal",
"(",
"0",
")",
",",
"normal",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This object displays whether an electrical source is normal or not.\"",
"::=",
"{",
"mySystemElectricalSourceIsNormalEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"abnormal",
0
],
[
"normal",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object displays whether an electrical source is normal or not."
],
null,
null,
null,
null
]
}Module: MY-SYSTEM-MIB
See published definition above
{'MY-SMI': ['myMgmt'], 'SNMPv2-TC': ['TruthValue', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP']}Related source files and packages:
Same file in 3610.zip.
Same file in 3610.zip.
Status in source: current.
Names: mySystemElectricalSourceIsNormal
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mySystemElectricalSourceIsNormal",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"noexist",
"(",
"1",
")",
",",
"existnopower",
"(",
"2",
")",
",",
"existreadypower",
"(",
"3",
")",
",",
"normal",
"(",
"4",
")",
",",
"powerbutabnormal",
"(",
"5",
")",
",",
"unknow",
"(",
"6",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This object displays whether an electrical source is normal or not.\"",
"::=",
"{",
"mySystemElectricalSourceIsNormalEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"noexist",
1
],
[
"existnopower",
2
],
[
"existreadypower",
3
],
[
"normal",
4
],
[
"powerbutabnormal",
5
],
[
"unknow",
6
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object displays whether an electrical source is normal or not."
],
null,
null,
null,
null
]
}Module: MY-SYSTEM-MIB
See published definition above
{'MY-SMI': ['myMgmt'], 'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Same file in 3610-MIB.rar.
Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DES7200-SYSTEM-MIB
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'DES7200-SMI': ['myMgmt'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.10.97.2.1.1.18.1.1 | mySystemElectricalSourceIsNormalIndex | 0 | 0 | |
| 1.3.6.1.4.1.171.10.97.2.1.1.18.1.3 | mySystemElectricalSourceName | 0 | 0 |