The OSPF Process's Links State Database.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.10.97.2.30.1.8.2
The OSPF Process's Links State Database.
Identification
{1 3 6 1 4 1 171 10 97 2 30 1 8 2}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
myOspfExtLsdbTable OBJECT-TYPE
SYNTAX SEQUENCE OF MyOspfExtLsdbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OSPF Process's Links State Database."
REFERENCE
"OSPF Version 2, Section 12 Link State Adver-
tisements"
::= { myOspfLsaDetailInfoMibsGroup 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The OSPF Process's Links State Database.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: myOspfExtLsdbTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"myOspfExtLsdbTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"MyOspfExtLsdbEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"The OSPF Process's Links State Database.\"",
"REFERENCE",
"\"OSPF Version 2, Section 12 Link State Adver- tisements\"",
"::=",
"{",
"myOspfLsaDetailInfoMibsGroup",
"2",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"MyOspfExtLsdbEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The OSPF Process's Links State Database."
],
[
"REFERENCE",
"OSPF Version 2, Section 12 Link State Adver- tisements"
],
null,
null,
null
]
}Module: MY-OSPF-MIB
See published definition above
{'MY-TC': ['ConfigStatus', 'IfIndex'], 'MY-SMI': ['myMgmt'], 'OSPF-MIB': ['AreaID', 'UpToMaxAge', 'Status', 'PositiveInteger', 'DesignatedRouterPriority', 'RouterID', 'HelloRange'], 'SNMPv2-TC': ['TruthValue', 'DisplayString', 'RowStatus', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'P-BRIDGE-MIB': ['EnabledStatus']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DES7200-OSPF-MIB
{'OSPF-MIB': ['AreaID', 'UpToMaxAge', 'Status', 'PositiveInteger', 'DesignatedRouterPriority', 'RouterID', 'HelloRange'], 'SNMPv2-TC': ['TruthValue', 'DisplayString', 'RowStatus', 'MacAddress'], 'DES7200-TC': ['ConfigStatus', 'IfIndex'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32'], 'DES7200-SMI': ['myMgmt'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'P-BRIDGE-MIB': ['EnabledStatus']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.10.97.2.30.1.8.2.1 | myOspfExtLsdbEntry | 14 | 14 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.10.97.2.30.1.8.1 | myOspfLsdbTable | 1 | 17 | |
| 1.3.6.1.4.1.171.10.97.2.30.1.8.3 | myOspfRouterLsaDetailTable | 1 | 5 | |
| 1.3.6.1.4.1.171.10.97.2.30.1.8.4 | myOspfNetWorkLsaDetailTable | 1 | 3 | |
| 1.3.6.1.4.1.171.10.97.2.30.1.8.5 | myOspfAreaLsaDBSumTable | 1 | 6 | |
| 1.3.6.1.4.1.171.10.97.2.30.1.8.6 | myOspfLsaDBSumTable | 1 | 5 |