This is the node's memory pool utilization currently.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.10.97.2.35.1.2.1.3
This is the node's memory pool utilization currently.
Identification
{1 3 6 1 4 1 171 10 97 2 35 1 2 1 3}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
myNodeMemoryPoolCurrentUtilization OBJECT-TYPE
SYNTAX Percent
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the node's memory pool utilization currently."
::= { myNodeMemoryPoolEntry 3 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This is the node's memory pool utilization currently.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: myNodeMemoryPoolCurrentUtilization
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"myNodeMemoryPoolCurrentUtilization",
"OBJECT-TYPE",
"SYNTAX",
"Percent",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This is the node's memory pool utilization currently.\"",
"::=",
"{",
"myNodeMemoryPoolEntry",
"3",
"}"
],
"syntax_tree": [
[
"row",
"Percent"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This is the node's memory pool utilization currently."
],
null,
null,
null,
null
]
}Module: MY-MEMORY-MIB
See published definition above
{'MY-SMI': ['myMgmt'], 'SNMPv2-TC': ['TruthValue', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Same file in 3610.zip.
Same file in 3610.zip.
Same file in 3610.zip.
Same file in 3610-MIB.rar.
Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DES7200-MEMORY-MIB
{'SNMPv2-TC': ['TruthValue', 'DisplayString', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Counter32'], 'DES7200-SMI': ['myMgmt'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.10.97.2.35.1.2.1.1 | myNodeMemoryPoolIndex | 0 | 0 | |
| 1.3.6.1.4.1.171.10.97.2.35.1.2.1.2 | myNodeMemoryPoolName | 0 | 0 | |
| 1.3.6.1.4.1.171.10.97.2.35.1.2.1.4 | myNodeMemoryPoolLowestUtilization | 0 | 0 | |
| 1.3.6.1.4.1.171.10.97.2.35.1.2.1.5 | myNodeMemoryPoolLargestUtilization | 0 | 0 | |
| 1.3.6.1.4.1.171.10.97.2.35.1.2.1.6 | myNodeMemoryPoolSize | 0 | 0 | |
| 1.3.6.1.4.1.171.10.97.2.35.1.2.1.7 | myNodeMemoryPoolUsed | 0 | 0 | |
| 1.3.6.1.4.1.171.10.97.2.35.1.2.1.8 | myNodeMemoryPoolFree | 0 | 0 | |
| 1.3.6.1.4.1.171.10.97.2.35.1.2.1.9 | myNodeMemoryPoolWarning | 0 | 0 | |
| 1.3.6.1.4.1.171.10.97.2.35.1.2.1.10 | myNodeMemoryPoolCritical | 0 | 0 |