OID reference

myntpSysPrecision

1.3.6.1.4.1.171.10.97.2.49.1.1.3

Description

Signed integer indicating the precision of the system clock, in seconds to the nearest power of two. The value must be rounded to the next larger power of two; for instance, a 50-Hz (20 ms) or 60-Hz (16.67 ms) power-frequency clock would be assigned the value -5 (31.25 ms), while a 1000-Hz (1 ms) crystal-controlled cl…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.171.10.97.2.49.1.1 (myntpSystem)
Node code
3
Node name
myntpSysPrecision
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.171.10.97.2.49.1.1.3
URN notation
urn:oid:1.3.6.1.4.1.171.10.97.2.49.1.1.3
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 171 10 97 2 49 1 1 3}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsGponMIB(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) nmsGponMIB(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) dlink-products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) nmsGponMIB(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) dlink-products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) nmsGponMIB(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(171) dlink-products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(171) products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(171) nmsGponMIB(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dlink(171) dlink-products(10) switchMib(97) myMgmt(2) myNtpMIB(49) myNtpMIBObjects(1) myntpSystem(1) myntpSysPrecision(3)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/171/10/97/2/49/1/1/3
  • /ISO/Identified-Organization/6/1/4/1/171/10/97/2/49/1/1/3
  • /ISO/3/6/1/4/1/171/10/97/2/49/1/1/3
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsGponMIB/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/d-link/nmsGponMIB/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/company/dlink-products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/company/products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/company/nmsGponMIB/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/my/dlink-products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/my/products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/my/nmsGponMIB/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/nms/dlink-products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/nms/products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprise/nms/nmsGponMIB/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • /iso/identified-organization/dod/internet/private/enterprises/dlink/dlink-products/switchMib/myMgmt/myNtpMIB/myNtpMIBObjects/myntpSystem/myntpSysPrecision
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
mandatory
Allowed ranges
-24–24

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.171.10.97.2.49.1.1.3.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

myntpSysPrecision OBJECT-TYPE
    SYNTAX INTEGER(-24..24)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Signed integer indicating the precision
        of the system clock, in seconds to the nearest
        power of two.  The value must be rounded to the
        next larger power of two; for instance, a 50-Hz
        (20 ms) or 60-Hz (16.67 ms) power-frequency clock
        would be assigned the value -5 (31.25 ms), while a
        1000-Hz (1 ms) crystal-controlled clock would be
        assigned the value -9 (1.95 ms)."
    ::= { myntpSystem 3 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Signed integer indicating the precision of the system clock, in seconds to the nearest power of two. The value must be rounded to the next larger power of two; for instance, a 50-Hz (20 ms) or 60-Hz (16.67 ms) power-frequency clock would be assigned the value -5 (31.25 ms), while a 1000-Hz (1 ms) crystal-controlled clock would be assigned the value -9 (1.95 ms).

Sources for this description

D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1D-Link official switch MIBs, D-Link MIB copies (LibreNMS/Observium Community)1 record · 3 sources

Description 1

myntpSysPrecision · mandatoryD-Link official switch MIBs, D-Link MIB copies (LibreNMS/Observium Community)3 sources

Status in source: mandatory.

Names: myntpSysPrecision

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "myntpSysPrecision",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "(",
    "-",
    "24",
    ".",
    ".",
    "24",
    ")",
    "ACCESS",
    "read-only",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Signed integer indicating the precision of the system clock, in seconds to the nearest power of two. The value must be rounded to the next larger power of two; for instance, a 50-Hz (20 ms) or 60-Hz (16.67 ms) power-frequency clock would be assigned the value -5 (31.25 ms), while a 1000-Hz (1 ms) crystal-controlled clock would be assigned the value -9 (1.95 ms).\"",
    "::=",
    "{",
    "myntpSystem",
    "3",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "integerSubType",
        [
          [
            -24,
            24
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Signed integer indicating the precision of the system clock, in seconds to the nearest power of two. The value must be rounded to the next larger power of two; for instance, a 50-Hz (20 ms) or 60-Hz (16.67 ms) power-frequency clock would be assigned the value -5 (31.25 ms), while a 1000-Hz (1 ms) crystal-controlled clock would be assigned the value -9 (1.95 ms)."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.171)

Henry P. Nagai

Siblings (6)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.171.10.97.2.49.1.1.1 myntpSysLeap00
1.3.6.1.4.1.171.10.97.2.49.1.1.2 myntpSysStratum00
1.3.6.1.4.1.171.10.97.2.49.1.1.4 myntpSysRootDelay00
1.3.6.1.4.1.171.10.97.2.49.1.1.5 myntpSysRootDispersion00
1.3.6.1.4.1.171.10.97.2.49.1.1.6 myntpSysRefId00
1.3.6.1.4.1.171.10.97.2.49.1.1.7 myntpSysRefTime00