off mode:fan is disabled.(the criteria is power<=30W and temperature<=0x4D); quiet mode:fan is running at low usage/speed.(the criteria is power<=72W and temperature<=0x41); normal mode:5-speed fan operation. in off mode, when power>30W or temperature>0x4D, it will recover to normal mode automatically. in quiet mode, when power>72W or temperature>0x41, it will recover to normal mode automatically.
OID reference
environmentFanCtrlMode
1.3.6.1.4.1.171.11.177.1000.2.2.3
Description
off mode:fan is disabled.(the criteria is power<=30W and temperature<=0x4D); quiet mode:fan is running at low usage/speed.(the criteria is power<=72W and temperature<=0x41); normal mode:5-speed fan operation. in off mode, when power>30W or temperature>0x4D, it will recover to normal mode automatically. in quiet mode, …
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.171.11.177.1000.2.2 (sysPeripheralGroup)
- Node code
- 3
- Node name
- environmentFanCtrlMode
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.171.11.177.1000.2.2.3
- URN notation
- urn:oid:1.3.6.1.4.1.171.11.177.1000.2.2.3
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 171 11 177 1000 2 2 3}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dlink(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) d-link(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) company(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) my(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nms(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dlink(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) d-link(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) company(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) my(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nms(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dlink(171) dlink-mgmt(11) dlink-DMS1250SeriesProj(177) dlink-dms-1250-Common(1000) dlinkSystem(2) sysPeripheralGroup(2) environmentFanCtrlMode(3)}
- Additional combinations skipped.
- OID-IRI notation
- /1/3/6/1/4/1/171/11/177/1000/2/2/3
- /ISO/Identified-Organization/6/1/4/1/171/11/177/1000/2/2/3
- /ISO/3/6/1/4/1/171/11/177/1000/2/2/3
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/enterprise/company/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/enterprise/my/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/enterprise/nms/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/enterprises/dlink/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/enterprises/d-link/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/enterprises/company/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/enterprises/my/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/enterprises/nms/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/ldap-enterprise/dlink/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/ldap-enterprise/d-link/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/ldap-enterprise/company/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/ldap-enterprise/my/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/ldap-enterprise/nms/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- /iso/identified-organization/dod/internet/private/vendor-objects/dlink/dlink-mgmt/dlink-DMS1250SeriesProj/dlink-dms-1250-Common/dlinkSystem/sysPeripheralGroup/environmentFanCtrlMode
- Additional combinations skipped.
SNMP properties
- Value type
- INTEGER
- Maximum access defined by MIB
- read-write
- Status in MIB
- current
- Default value
- normal
Enumerated values
| Value | Name |
|---|---|
| 0 | off |
| 1 | quiet |
| 2 | normal |
Using this OID with SNMP
At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.
snmpget [connection options] DEVICE .1.3.6.1.4.1.171.11.177.1000.2.2.3.0
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
environmentFanCtrlMode OBJECT-TYPE
SYNTAX INTEGER {
off(0),
quiet(1),
normal(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"off mode:fan is disabled.(the criteria is power<=30W and temperature<=0x4D);
quiet mode:fan is running at low usage/speed.(the criteria is power<=72W and temperature<=0x41);
normal mode:5-speed fan operation.
in off mode, when power>30W or temperature>0x4D, it will recover to normal mode automatically.
in quiet mode, when power>72W or temperature>0x41, it will recover to normal mode automatically."
DEFVAL { normal }
::= { sysPeripheralGroup 3 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Records for description 1D-Link official switch MIBs
environmentFanCtrlMode · currentD-Link official switch MIBs
Status in source: current.
Names: environmentFanCtrlMode
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"environmentFanCtrlMode",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"off",
"(",
"0",
")",
",",
"quiet",
"(",
"1",
")",
",",
"normal",
"(",
"2",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"off mode:fan is disabled.(the criteria is power<=30W and temperature<=0x4D); quiet mode:fan is running at low usage/speed.(the criteria is power<=72W and temperature<=0x41); normal mode:5-speed fan operation. in off mode, when power>30W or temperature>0x4D, it will recover to normal mode automatically. in quiet mode, when power>72W or temperature>0x41, it will recover to normal mode automatically.\"",
"DEFVAL",
"{",
"normal",
"}",
"::=",
"{",
"sysPeripheralGroup",
"3",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"off",
0
],
[
"quiet",
1
],
[
"normal",
2
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"off mode:fan is disabled.(the criteria is power<=30W and temperature<=0x4D); quiet mode:fan is running at low usage/speed.(the criteria is power<=72W and temperature<=0x41); normal mode:5-speed fan operation. in off mode, when power>30W or temperature>0x4D, it will recover to normal mode automatically. in quiet mode, when power>72W or temperature>0x41, it will recover to normal mode automatically."
],
null,
null,
null,
[
"DEFVAL",
"normal"
]
]
}- D-Link official switch MIBs
· Publisher's source file: Source package: DMS-1250-SERIES-V1.03.005-MIB.rar
Module: DLINK-DMS-1250-SERIES-MIB
See published definition above
· Download DMS-1250-SERIES-V1.03.005.mibModule imports
{'IF-MIB': ['InterfaceIndex', 'InterfaceIndexOrZero'], 'SNMPv2-TC': ['RowStatus', 'TruthValue', 'DisplayString', 'TEXTUAL-CONVENTION', 'MacAddress', 'TimeStamp', 'DateAndTime', 'TimeInterval'], 'BRIDGE-MIB': ['dot1dBridge', 'dot1dBasePortEntry', 'dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'enterprises', 'IpAddress', 'Integer32', 'Unsigned32', 'TimeTicks', 'Counter32', 'Counter64', 'Gauge32'], 'Q-BRIDGE-MIB': ['VlanId'], 'DIFFSERV-DSCP-TC': ['Dscp'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString', 'SnmpEngineID', 'SnmpSecurityLevel'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}Related source files and packages:
- MIB package: DMS-1250-SERIES-V1.03.005-MIB.rar
- MIB package: DMS-1250-SERIES-V1.03.005-MIB.rar
- MIB package: DMS-1250-SERIES-V1.03.005-MIB.rar
Show more related files and packages
Same file in DMS-1250-SERIES-V1.03.005-MIB.rar.
Same file in DMS-1250-SERIES-V1.03.005-MIB.rar.
Same file in DMS-1250-SERIES-V1.03.005-MIB.rar.
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.171)
Siblings (5)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.11.177.1000.2.2.1 | environmentFanTrap | 0 | 0 | |
| 1.3.6.1.4.1.171.11.177.1000.2.2.2 | environmentTemperTrap | 0 | 0 | |
| 1.3.6.1.4.1.171.11.177.1000.2.2.4 | environmentFanTable | 1 | 4 | |
| 1.3.6.1.4.1.171.11.177.1000.2.2.5 | environmentTemper | 4 | 4 | |
| 1.3.6.1.4.1.171.11.177.1000.2.2.6 | envTraps | 1 | 9 |