The object specifies the management VLAN on a switch. A value of zero indicates that no management VLAN has been configured. It is required to configure the global v2VlanManagementVlanId and enable v2svEnabled to start the management VLAN function.
OID reference
v2VlanManagementVlanId
1.3.6.1.4.1.171.11.178.1000.26.1.3.2
Description
The object specifies the management VLAN on a switch. A value of zero indicates that no management VLAN has been configured. It is required to configure the global v2VlanManagementVlanId and enable v2svEnabled to start the management VLAN function.
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.171.11.178.1000.26.1.3 (v2VlanManagementVlanGlobal)
- Node code
- 2
- Node name
- v2VlanManagementVlanId
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.171.11.178.1000.26.1.3.2
- URN notation
- urn:oid:1.3.6.1.4.1.171.11.178.1000.26.1.3.2
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 171 11 178 1000 26 1 3 2}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dlink(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) d-link(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) company(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) my(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nms(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dlink(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) d-link(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) company(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) my(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nms(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dlink(171) dlink-mgmt(11) dlinkDSS200GSeriesProj(178) dlinkDSS200GCommonV2(1000) primeV2VlanMIB(26) v2VlanMIBObjects(1) v2VlanManagementVlanGlobal(3) v2VlanManagementVlanId(2)}
- Additional combinations skipped.
- OID-IRI notation
- /1/3/6/1/4/1/171/11/178/1000/26/1/3/2
- /ISO/Identified-Organization/6/1/4/1/171/11/178/1000/26/1/3/2
- /ISO/3/6/1/4/1/171/11/178/1000/26/1/3/2
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/dlink/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/enterprise/d-link/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/enterprise/company/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/enterprise/my/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/enterprise/nms/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/enterprises/dlink/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/enterprises/d-link/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/enterprises/company/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/enterprises/my/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/enterprises/nms/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/ldap-enterprise/dlink/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/ldap-enterprise/d-link/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/ldap-enterprise/company/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/ldap-enterprise/my/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/ldap-enterprise/nms/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- /iso/identified-organization/dod/internet/private/vendor-objects/dlink/dlink-mgmt/dlinkDSS200GSeriesProj/dlinkDSS200GCommonV2/primeV2VlanMIB/v2VlanMIBObjects/v2VlanManagementVlanGlobal/v2VlanManagementVlanId
- Additional combinations skipped.
SNMP properties
- Value type
- VlanIdOrNone
- Maximum access defined by MIB
- read-write
- Status in MIB
- current
- Default value
- 0
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
v2VlanManagementVlanId OBJECT-TYPE
SYNTAX VlanIdOrNone
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The object specifies the management VLAN on a switch.
A value of zero indicates that no management VLAN has been
configured.
It is required to configure the global v2VlanManagementVlanId and enable
v2svEnabled to start the management VLAN function."
DEFVAL { 0 }
::= { v2VlanManagementVlanGlobal 2 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Records for description 1D-Link official switch MIBs
v2VlanManagementVlanId · currentD-Link official switch MIBs
Status in source: current.
Names: v2VlanManagementVlanId
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"v2VlanManagementVlanId",
"OBJECT-TYPE",
"SYNTAX",
"VlanIdOrNone",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The object specifies the management VLAN on a switch. A value of zero indicates that no management VLAN has been configured. It is required to configure the global v2VlanManagementVlanId and enable v2svEnabled to start the management VLAN function.\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"v2VlanManagementVlanGlobal",
"2",
"}"
],
"syntax_tree": [
[
"row",
"VlanIdOrNone"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The object specifies the management VLAN on a switch. A value of zero indicates that no management VLAN has been configured. It is required to configure the global v2VlanManagementVlanId and enable v2svEnabled to start the management VLAN function."
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}- D-Link official switch MIBs
· Publisher's source file: Source package: DSS-200G-xx_A1_MIB_V1-00-020.7z
Module: DLINKPV2-VLAN-MIB
See published definition above
· Download DLINKPV2-VLAN-MIB.mibModule imports
{'SNMPv2-TC': ['RowStatus', 'TruthValue', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBasePort'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'Q-BRIDGE-MIB': ['VlanId', 'VlanIdOrNone', 'PortList', 'dot1vProtocolPortGroupId'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetAddressPrefixLength'], 'DSS200GSERMGMT-MIB': ['dlinkDSS200GCommonV2']}Related source files and packages:
- MIB package: DSS-200G-xx_A1_MIB_V1-00-020.7z
- MIB package: DSS-200G-xx_A1_MIB_V1-00-020.7z
- MIB package: DSS-200G-xx_A1_MIB_V1-00-020.7z
Show more related files and packages
Same file in DSS-200G-xx_A1_MIB_V1-00-020.7z.
Same file in DSS-200G-xx_A1_MIB_V1-00-020.7z.
Same file in DSS-200G-xx_A1_MIB_V1-00-020.7z.
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.171)
Siblings (1)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.11.178.1000.26.1.3.1 | v2VlanManagementVlanEnabled | 0 | 0 |