Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"swPortTrunkMasterPort",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The object indicates the master port number of the port trunk entry. The first port of the trunk is implicitly configured to be the master logical port. When using a Port Trunk, you can not configure the other ports of the group except the master port. Their configuration must be the same as the master port (e.g. speed, duplex, enabled/disabled, flow control, and so on).\"",
"::=",
"{",
"swPortTrunkEntry",
"2",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The object indicates the master port number of the port trunk entry. The first port of the trunk is implicitly configured to be the master logical port. When using a Port Trunk, you can not configure the other ports of the group except the master port. Their configuration must be the same as the master port (e.g. speed, duplex, enabled/disabled, flow control, and so on)."
],
null,
null,
null,
null
]
}