A table that contains CFM extension lock control information.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.12.86.1.2
A table that contains CFM extension lock control information.
Identification
{1 3 6 1 4 1 171 12 86 1 2}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
swCFMExtMgmtLockCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwCFMExtMgmtLockCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains CFM extension lock control information."
::= { swCFMExtFaultMgmt 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
A table that contains CFM extension lock control information.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; representative source files are shown for each definition.
Status in source: current.
Names: swCFMExtMgmtLockCtrlTable
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"swCFMExtMgmtLockCtrlTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"SwCFMExtMgmtLockCtrlEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"A table that contains CFM extension lock control information.\"",
"::=",
"{",
"swCFMExtFaultMgmt",
"2",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"SwCFMExtMgmtLockCtrlEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A table that contains CFM extension lock control information."
],
null,
null,
null,
null
]
}Module: CFMEXTENSION-MIB
See published definition above
{'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE'], 'DLINK-ID-REC-MIB': ['dlink-common-mgmt'], 'IEEE8021-CFM-MIB': ['dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'Dot1agCfmMepId', 'dot1agCfmMaMepListIdentifier', 'Dot1agCfmMDLevel']}Module: CFMEXTENSION-MIB
{'SNMPv2-TC': ['TimeStamp', 'TruthValue', 'MacAddress', 'DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Counter32'], 'DLINK-ID-REC-MIB': ['dlink-common-mgmt'], 'IEEE8021-CFM-MIB': ['dot1agCfmMdIndex', 'dot1agCfmMaIndex', 'dot1agCfmMepIdentifier', 'dot1agCfmMaMepListIdentifier', 'Dot1agCfmMDLevel']}Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.12.86.1.2.1 | swCFMExtMgmtLockCtrlEntry | 1 | 1 |
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.12.86.1.1 | swCFMExtMgmtTable | 1 | 9 |