The compliance statement for DLINKSW-DAI-MIB
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.171.14.130.2.1.1
The compliance statement for DLINKSW-DAI-MIB
Identification
{1 3 6 1 4 1 171 14 130 2 1 1}
The displayed source records contain one distinct definition. Compare its source records.
dDaiMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for DLINKSW-DAI-MIB"
MODULE
MANDATORY-GROUPS {
dDaiIfConfigGroup
}
GROUP dDaiVlanCtrlGroup
DESCRIPTION
"This group is mandatory only for the platform which supports
enabling Dynamic ARP Inspection per VLAN."
GROUP dDaiVlanCfgGroup
DESCRIPTION
"This group is mandatory only for the platform which supports
enabling Dynamic ARP Inspection per VLAN."
GROUP dDaiLoggingConfigGroup
DESCRIPTION
"This group is mandatory only for the platform which supports
enabling Dynamic ARP Inspection logging at the device level."
GROUP dDaiIfRateLimitGroup
DESCRIPTION
"This group is mandatory only for the platform which supports
Dynamic ARP Inspection rate limit per interface."
GROUP dDaiAddressValidationGroup
DESCRIPTION
"This group is mandatory only for the platform which supports
address validation configuration."
GROUP dDaiLogBufferGroup
DESCRIPTION
"This group is mandatory only for the platform which supports
log buffer information for Dynamic ARP Inspection feature."
GROUP dDaiVlanStatisticsGroup
DESCRIPTION
"This group is mandatory only for the platform which supports
Dynamic ARP Inspection statistics per VLAN."
GROUP dDaiAclGroup
DESCRIPTION
"This group is mandatory only for the platform which supports
static ARP inspection configuration."
GROUP dDaiClearStatsGroup
DESCRIPTION
"This group is mandatory only for the platform which supports
clear ARP inspection statistics."
OBJECT dDaiVlanFilterArpAclName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT dDaiVlanFilterArpAclStatic
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT dDaiVlanCfgRowStatus
SYNTAX INTEGER {
active(1)
}
WRITE-SYNTAX INTEGER {
createAndGo(4),
destroy(6)
}
MIN-ACCESS read-only
DESCRIPTION
"Read-create access is not required."
OBJECT dDaiIfTrustEnabled
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT dDaiLogBufferSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT dDaiAddressValidate
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT dDaiClearLogBuffer
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { dDaiMIBCompliances 1 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
The compliance statement for DLINKSW-DAI-MIB
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: dDaiMIBCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"dDaiMIBCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for DLINKSW-DAI-MIB\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"dDaiIfConfigGroup",
"}",
"GROUP",
"dDaiVlanCtrlGroup",
"DESCRIPTION",
"\"This group is mandatory only for the platform which supports enabling Dynamic ARP Inspection per VLAN.\"",
"GROUP",
"dDaiVlanCfgGroup",
"DESCRIPTION",
"\"This group is mandatory only for the platform which supports enabling Dynamic ARP Inspection per VLAN.\"",
"GROUP",
"dDaiLoggingConfigGroup",
"DESCRIPTION",
"\"This group is mandatory only for the platform which supports enabling Dynamic ARP Inspection logging at the device level.\"",
"GROUP",
"dDaiIfRateLimitGroup",
"DESCRIPTION",
"\"This group is mandatory only for the platform which supports Dynamic ARP Inspection rate limit per interface.\"",
"GROUP",
"dDaiAddressValidationGroup",
"DESCRIPTION",
"\"This group is mandatory only for the platform which supports address validation configuration.\"",
"GROUP",
"dDaiLogBufferGroup",
"DESCRIPTION",
"\"This group is mandatory only for the platform which supports log buffer information for Dynamic ARP Inspection feature.\"",
"GROUP",
"dDaiVlanStatisticsGroup",
"DESCRIPTION",
"\"This group is mandatory only for the platform which supports Dynamic ARP Inspection statistics per VLAN.\"",
"GROUP",
"dDaiAclGroup",
"DESCRIPTION",
"\"This group is mandatory only for the platform which supports static ARP inspection configuration.\"",
"GROUP",
"dDaiClearStatsGroup",
"DESCRIPTION",
"\"This group is mandatory only for the platform which supports clear ARP inspection statistics.\"",
"OBJECT",
"dDaiVlanFilterArpAclName",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"dDaiVlanFilterArpAclStatic",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"dDaiVlanCfgRowStatus",
"SYNTAX",
"INTEGER",
"{",
"active",
"(",
"1",
")",
"}",
"WRITE-SYNTAX",
"INTEGER",
"{",
"createAndGo",
"(",
"4",
")",
",",
"destroy",
"(",
"6",
")",
"}",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Read-create access is not required.\"",
"OBJECT",
"dDaiIfTrustEnabled",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"dDaiLogBufferSize",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"dDaiAddressValidate",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"dDaiClearLogBuffer",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"::=",
"{",
"dDaiMIBCompliances",
"1",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for DLINKSW-DAI-MIB"
],
null,
[
"ComplianceModules",
[
[
null,
[
"dDaiIfConfigGroup",
"dDaiVlanCtrlGroup",
"dDaiVlanCfgGroup",
"dDaiLoggingConfigGroup",
"dDaiIfRateLimitGroup",
"dDaiAddressValidationGroup",
"dDaiLogBufferGroup",
"dDaiVlanStatisticsGroup",
"dDaiAclGroup",
"dDaiClearStatsGroup"
]
]
]
]
]
}Module: DLINKSW-DAI-MIB
See published definition above
{'IF-MIB': ['ifIndex', 'InterfaceIndex'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'DateAndTime', 'RowStatus', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'Gauge32', 'Integer32', 'Unsigned32', 'Counter64', 'IpAddress', 'OBJECT-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'Q-BRIDGE-MIB': ['VlanId', 'VlanIdOrNone'], 'DLINKSW-TC-MIB': ['Dlink2kVlanList'], 'DLINK-ID-REC-MIB': ['dlinkIndustrialCommon'], 'INET-ADDRESS-MIB': ['InetAddressIPv4']}Related source files and packages:
Same file in DXS-3610_A1_MIB_v1.01.zip.
Same file in DXS-3600_32S_MIB_R2.40.zip.
Same file in DXS-3600_32S_MIB_R2.40.zip.
Same file in DXS3400_MIB_20181212.zip.
Vendor MIB copy from the LibreNMS archive. D-Link support.
Module: DLINKSW-DAI-MIB
{'IF-MIB': ['ifIndex', 'InterfaceIndex'], 'SNMPv2-TC': ['TruthValue', 'MacAddress', 'DateAndTime', 'RowStatus', 'DisplayString', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'Gauge32', 'Integer32', 'Unsigned32', 'Counter64', 'IpAddress', 'OBJECT-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'Q-BRIDGE-MIB': ['VlanId', 'VlanIdOrNone'], 'DLINKSW-TC-MIB': ['Dlink2kVlanList'], 'DLINK-ID-REC-MIB': ['dlinkIndustrialCommon'], 'INET-ADDRESS-MIB': ['InetAddressIPv4']}Related source files and packages:
Registration