A collection of objects provides information of the system temperature.
Sources for this description
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.171.14.5.2.2.4
A collection of objects provides information of the system temperature.
Identification
{1 3 6 1 4 1 171 14 5 2 2 4}
Available source records contain 2 distinct definitions; some records may not include a definition.
dEntityExtSystemInfoGroup OBJECT-GROUP
OBJECTS {
dEntityExtUnitStatus,
dEntityExtUnitUpTime,
dEntityExtMemUtilTotal,
dEntityExtMemUtilUsed,
dEntityExtMemUtilFree,
dEntityExtCpuUtilFiveSeconds,
dEntityExtCpuUtilOneMinute,
dEntityExtCpuUtilFiveMinutes,
dEntityExtVersionBootloader,
dEntityExtVersionRuntime
}
STATUS current
DESCRIPTION
"A collection of objects provides information of the system temperature."
::= { dEntityExtMIBGroups 4 }dEntityExtSystemInfoGroup OBJECT-GROUP
OBJECTS {
dEntityExtUnitStatus,
dEntityExtUnitUpTime,
dEntityExtMemUtilTotal,
dEntityExtMemUtilUsed,
dEntityExtMemUtilFree,
dEntityExtCpuUtilFiveSeconds,
dEntityExtCpuUtilOneMinute,
dEntityExtCpuUtilFiveMinutes,
dEntityExtVersionBootloader,
dEntityExtVersionRuntime,
dEntityExtHistoryType,
dEntityExtHistorySlot,
dEntityExtHistoryUtilCPU,
dEntityExtHistoryUtilMemory,
dEntityExtHistoryUtilStartTime,
dEntityExtHistoryUtilEndTime
}
STATUS current
DESCRIPTION
"A collection of objects provides information of the system temperature."
::= { dEntityExtMIBGroups 4 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
A collection of objects provides information of the system temperature.
D-Link official switch MIBsD-Link MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: dEntityExtSystemInfoGroup
{
"smi_kind": "OBJECT-GROUP",
"definition": [
"dEntityExtSystemInfoGroup",
"OBJECT-GROUP",
"OBJECTS",
"{",
"dEntityExtUnitStatus",
",",
"dEntityExtUnitUpTime",
",",
"dEntityExtMemUtilTotal",
",",
"dEntityExtMemUtilUsed",
",",
"dEntityExtMemUtilFree",
",",
"dEntityExtCpuUtilFiveSeconds",
",",
"dEntityExtCpuUtilOneMinute",
",",
"dEntityExtCpuUtilFiveMinutes",
",",
"dEntityExtVersionBootloader",
",",
"dEntityExtVersionRuntime",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"A collection of objects provides information of the system temperature.\"",
"::=",
"{",
"dEntityExtMIBGroups",
"4",
"}"
],
"syntax_tree": [
[
"Objects",
[
"dEntityExtUnitStatus",
"dEntityExtUnitUpTime",
"dEntityExtMemUtilTotal",
"dEntityExtMemUtilUsed",
"dEntityExtMemUtilFree",
"dEntityExtCpuUtilFiveSeconds",
"dEntityExtCpuUtilOneMinute",
"dEntityExtCpuUtilFiveMinutes",
"dEntityExtVersionBootloader",
"dEntityExtVersionRuntime"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A collection of objects provides information of the system temperature."
],
null
]
}Module: DLINKSW-ENTITY-EXT-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'DLINK-ID-REC-MIB': ['dlinkIndustrialCommon']}Related source files and packages:
Same file in DXS-3600_32S_MIB_R2.40.zip.
Same file in DXS-3600_32S_MIB_R2.40.zip.
Same file in DXS-1100-R1.10-mibs-20161221.zip.
Same file in DXS-1100_MIB_20160105.rar.
Vendor MIB copy from the LibreNMS archive. D-Link support.
Module: DLINKSW-ENTITY-EXT-MIB
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'DLINK-ID-REC-MIB': ['dlinkIndustrialCommon']}Related source files and packages:
Vendor MIB copy from the Observium Community archive. D-Link support.
Module: DLINKSW-ENTITY-EXT-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'DLINK-ID-REC-MIB': ['dlinkIndustrialCommon']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: DLINKSW-ENTITY-EXT-MIB
Same published definition (formatting differs; exact original is in the source file)
{'SNMPv2-TC': ['DisplayString'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'DLINK-ID-REC-MIB': ['dlinkIndustrialCommon']}Related source files and packages:
Status in source: current.
Names: dEntityExtSystemInfoGroup
{
"smi_kind": "OBJECT-GROUP",
"definition": [
"dEntityExtSystemInfoGroup",
"OBJECT-GROUP",
"OBJECTS",
"{",
"dEntityExtUnitStatus",
",",
"dEntityExtUnitUpTime",
",",
"dEntityExtMemUtilTotal",
",",
"dEntityExtMemUtilUsed",
",",
"dEntityExtMemUtilFree",
",",
"dEntityExtCpuUtilFiveSeconds",
",",
"dEntityExtCpuUtilOneMinute",
",",
"dEntityExtCpuUtilFiveMinutes",
",",
"dEntityExtVersionBootloader",
",",
"dEntityExtVersionRuntime",
",",
"dEntityExtHistoryType",
",",
"dEntityExtHistorySlot",
",",
"dEntityExtHistoryUtilCPU",
",",
"dEntityExtHistoryUtilMemory",
",",
"dEntityExtHistoryUtilStartTime",
",",
"dEntityExtHistoryUtilEndTime",
"}",
"STATUS",
"current",
"DESCRIPTION",
"\"A collection of objects provides information of the system temperature.\"",
"::=",
"{",
"dEntityExtMIBGroups",
"4",
"}"
],
"syntax_tree": [
[
"Objects",
[
"dEntityExtUnitStatus",
"dEntityExtUnitUpTime",
"dEntityExtMemUtilTotal",
"dEntityExtMemUtilUsed",
"dEntityExtMemUtilFree",
"dEntityExtCpuUtilFiveSeconds",
"dEntityExtCpuUtilOneMinute",
"dEntityExtCpuUtilFiveMinutes",
"dEntityExtVersionBootloader",
"dEntityExtVersionRuntime",
"dEntityExtHistoryType",
"dEntityExtHistorySlot",
"dEntityExtHistoryUtilCPU",
"dEntityExtHistoryUtilMemory",
"dEntityExtHistoryUtilStartTime",
"dEntityExtHistoryUtilEndTime"
]
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"A collection of objects provides information of the system temperature."
],
null
]
}Module: DLINKSW-ENTITY-EXT-MIB
See published definition above
{'SNMPv2-TC': ['DisplayString', 'TruthValue', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'DLINK-ID-REC-MIB': ['dlinkIndustrialCommon']}Related source files and packages:
Same file in DXS-1210-R1.00-MIB-20200515.7z.
Same file in DXS-1210-R1.00-MIB-20200515.7z.
Same file in DGS-1520_MIB_20200430.zip.
Same file in DGS-1520_MIB_20200430.zip.
Module: DLINKSW-ENTITY-EXT-MIB
{'SNMPv2-TC': ['DisplayString', 'TruthValue', 'DateAndTime'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Unsigned32', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'DLINK-ID-REC-MIB': ['dlinkIndustrialCommon']}Related source files and packages:
Same file in DXS-3610_A1_MIB_v1.01.zip.
Same file in DXS3400_MIB_20181212.zip.
Same file in DXS-3400_MIB_R2.0.zip.
Same file in DXS-3400_MIB_R1.00.B040.zip.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.14.5.2.2.1 | dEntityExtTempGroup | 0 | 0 | |
| 1.3.6.1.4.1.171.14.5.2.2.2 | dEntityExtFanGroup | 0 | 0 | |
| 1.3.6.1.4.1.171.14.5.2.2.3 | dEntityExtPowerGroup | 0 | 0 | |
| 1.3.6.1.4.1.171.14.5.2.2.5 | dEntityExtGenericNotifInfoGroup | 0 | 0 | |
| 1.3.6.1.4.1.171.14.5.2.2.6 | dEntityExtFanNotifGroup | 0 | 0 | |
| 1.3.6.1.4.1.171.14.5.2.2.7 | dEntityExtThermalNotifGroup | 0 | 0 | |
| 1.3.6.1.4.1.171.14.5.2.2.8 | dEntityExtPowerNotifGroup | 0 | 0 | |
| 1.3.6.1.4.1.171.14.5.2.2.9 | dEntityExtAirFlowNotifGroup | 0 | 0 | |
| 1.3.6.1.4.1.171.14.5.2.2.10 | dEntityExtFactoryResetButtonNotifGroup | 0 | 0 | |
| 1.3.6.1.4.1.171.14.5.2.2.11 | dEntityExtHistoryInfoGroup | 0 | 0 |