This table consists of a list of configuration for the PD alive check function for ports. The PD alive check feature provides the solution for PD device that has the stop working or no response problem via Ping mechanism. Detailed Process: The detailed processes are described as follows: 1. The system needs to periodically monitor the specific PD by using Ping function. If there is no response, system takes one of the following actions: (1) Reset: Switch resets (disable then enable) PoE power on the port which connects to a PD under monitoring. (2) Notify: Switch sends logs and traps to notify the administrator. (3) Both: Switch sends logs and traps, and resets the PoE port power. 2. The system should implement the retry mechanism to check PD aliveness, hence the system will reset the PoE port power feeding after the retry by using Ping without any response from a PD. 3. If the action is Reset or Both, the system needs to wait for PD recovery from rebooting and then executes the Ping function again. Besides, the waiting time can be configured by users. 4. If PoE schedule (time range) function is configured on the port which enables the PD Alive Check function, the time range function has the top priority, and therefore PD Alive Check function will not work while PoE time range function is still active. 5. This function only takes effect on PoE enabled port with power feeding. Note: It is required to setup IP settings properly that the PD can be reachable for Ping, otherwise this function cannot work as expected. Limitation 1. Support Ping Function: If the PD does not support ICMP, this function cannot work normally. 2. Direct-Connected PD: The Reset Action can only work on the direct-connected PD. If the PD is not connected directly, the Reset Action may not work as expected. 3. PD Also Acts as PSE: If the direct-connected PD is also a PSE, all the next level PDs connect to this PSE will be power cycling whenever PD Alive Check function takes effect on 'Reset' or 'Both' Action.
OID reference
esPoeIfPdAliveCfgTable
1.3.6.1.4.1.171.17.24.1.3.3
Description
This table consists of a list of configuration for the PD alive check function for ports. The PD alive check feature provides the solution for PD device that has the stop working or no response problem via Ping mechanism. Detailed Process: The detailed processes are described as follows: 1. The system needs to periodi…
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.171.17.24.1.3 (esPoeIfObjects)
- Node code
- 3
- Node name
- esPoeIfPdAliveCfgTable
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.171.17.24.1.3.3
- URN notation
- urn:oid:1.3.6.1.4.1.171.17.24.1.3.3
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 171 17 24 1 3 3}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dlink(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) d-link(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) company(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) my(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nms(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dlink(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) d-link(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) company(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) my(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nms(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dlink(171) dlinkCommon(17) dlinkEsPoeExtMIB(24) esPoeMIBObjects(1) esPoeIfObjects(3) esPoeIfPdAliveCfgTable(3)}
- Additional combinations skipped.
- OID-IRI notation
- /1/3/6/1/4/1/171/17/24/1/3/3
- /ISO/Identified-Organization/6/1/4/1/171/17/24/1/3/3
- /ISO/3/6/1/4/1/171/17/24/1/3/3
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/dlink/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/enterprise/d-link/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/enterprise/company/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/enterprise/my/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/enterprise/nms/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/enterprises/dlink/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/enterprises/d-link/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/enterprises/company/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/enterprises/my/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/enterprises/nms/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/ldap-enterprise/dlink/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/ldap-enterprise/d-link/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/ldap-enterprise/company/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/ldap-enterprise/my/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/ldap-enterprise/nms/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- /iso/identified-organization/dod/internet/private/vendor-objects/dlink/dlinkCommon/dlinkEsPoeExtMIB/esPoeMIBObjects/esPoeIfObjects/esPoeIfPdAliveCfgTable
- Additional combinations skipped.
SNMP properties
- Value type
- SEQUENCE OF EsPoeIfPdAliveCfgEntry
- Maximum access defined by MIB
- not-accessible
- Status in MIB
- current
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
esPoeIfPdAliveCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF EsPoeIfPdAliveCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table consists of a list of configuration for the PD
alive check function for ports.
The PD alive check feature provides the solution for
PD device that has the stop working or no response
problem via Ping mechanism.
Detailed Process:
The detailed processes are described as follows:
1. The system needs to periodically monitor the
specific PD by using Ping function. If there is no
response, system takes one of the following actions:
(1) Reset: Switch resets (disable then enable) PoE
power on the port which connects to a PD under monitoring.
(2) Notify: Switch sends logs and traps to notify the administrator.
(3) Both: Switch sends logs and traps, and resets the PoE port power.
2. The system should implement the retry mechanism to check
PD aliveness, hence the system will reset the PoE port power
feeding after the retry by using Ping without any response from a PD.
3. If the action is Reset or Both, the system needs
to wait for PD recovery from rebooting and then executes
the Ping function again. Besides, the waiting time can
be configured by users.
4. If PoE schedule (time range) function is configured
on the port which enables the PD Alive Check function,
the time range function has the top priority, and
therefore PD Alive Check function will not work
while PoE time range function is still active.
5. This function only takes effect on PoE enabled
port with power feeding.
Note: It is required to setup IP settings properly that
the PD can be reachable for Ping, otherwise this function
cannot work as expected.
Limitation
1. Support Ping Function: If the PD does not support ICMP,
this function cannot work normally.
2. Direct-Connected PD: The Reset Action can only work on
the direct-connected PD. If the PD is not connected directly,
the Reset Action may not work as expected.
3. PD Also Acts as PSE: If the direct-connected PD is also a PSE,
all the next level PDs connect to this PSE will be power cycling
whenever PD Alive Check function takes effect on 'Reset' or 'Both' Action."
::= { esPoeIfObjects 3 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Records for description 1D-Link official switch MIBs
esPoeIfPdAliveCfgTable · currentD-Link official switch MIBs
Status in source: current.
Names: esPoeIfPdAliveCfgTable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"esPoeIfPdAliveCfgTable",
"OBJECT-TYPE",
"SYNTAX",
"SEQUENCE",
"OF",
"EsPoeIfPdAliveCfgEntry",
"MAX-ACCESS",
"not-accessible",
"STATUS",
"current",
"DESCRIPTION",
"\"This table consists of a list of configuration for the PD alive check function for ports. The PD alive check feature provides the solution for PD device that has the stop working or no response problem via Ping mechanism. Detailed Process: The detailed processes are described as follows: 1. The system needs to periodically monitor the specific PD by using Ping function. If there is no response, system takes one of the following actions: (1) Reset: Switch resets (disable then enable) PoE power on the port which connects to a PD under monitoring. (2) Notify: Switch sends logs and traps to notify the administrator. (3) Both: Switch sends logs and traps, and resets the PoE port power. 2. The system should implement the retry mechanism to check PD aliveness, hence the system will reset the PoE port power feeding after the retry by using Ping without any response from a PD. 3. If the action is Reset or Both, the system needs to wait for PD recovery from rebooting and then executes the Ping function again. Besides, the waiting time can be configured by users. 4. If PoE schedule (time range) function is configured on the port which enables the PD Alive Check function, the time range function has the top priority, and therefore PD Alive Check function will not work while PoE time range function is still active. 5. This function only takes effect on PoE enabled port with power feeding. Note: It is required to setup IP settings properly that the PD can be reachable for Ping, otherwise this function cannot work as expected. Limitation 1. Support Ping Function: If the PD does not support ICMP, this function cannot work normally. 2. Direct-Connected PD: The Reset Action can only work on the direct-connected PD. If the PD is not connected directly, the Reset Action may not work as expected. 3. PD Also Acts as PSE: If the direct-connected PD is also a PSE, all the next level PDs connect to this PSE will be power cycling whenever PD Alive Check function takes effect on 'Reset' or 'Both' Action.\"",
"::=",
"{",
"esPoeIfObjects",
"3",
"}"
],
"syntax_tree": [
[
"conceptualTable",
[
"row",
"EsPoeIfPdAliveCfgEntry"
]
],
null,
[
"MaxAccessPart",
"not-accessible"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This table consists of a list of configuration for the PD alive check function for ports. The PD alive check feature provides the solution for PD device that has the stop working or no response problem via Ping mechanism. Detailed Process: The detailed processes are described as follows: 1. The system needs to periodically monitor the specific PD by using Ping function. If there is no response, system takes one of the following actions: (1) Reset: Switch resets (disable then enable) PoE power on the port which connects to a PD under monitoring. (2) Notify: Switch sends logs and traps to notify the administrator. (3) Both: Switch sends logs and traps, and resets the PoE port power. 2. The system should implement the retry mechanism to check PD aliveness, hence the system will reset the PoE port power feeding after the retry by using Ping without any response from a PD. 3. If the action is Reset or Both, the system needs to wait for PD recovery from rebooting and then executes the Ping function again. Besides, the waiting time can be configured by users. 4. If PoE schedule (time range) function is configured on the port which enables the PD Alive Check function, the time range function has the top priority, and therefore PD Alive Check function will not work while PoE time range function is still active. 5. This function only takes effect on PoE enabled port with power feeding. Note: It is required to setup IP settings properly that the PD can be reachable for Ping, otherwise this function cannot work as expected. Limitation 1. Support Ping Function: If the PD does not support ICMP, this function cannot work normally. 2. Direct-Connected PD: The Reset Action can only work on the direct-connected PD. If the PD is not connected directly, the Reset Action may not work as expected. 3. PD Also Acts as PSE: If the direct-connected PD is also a PSE, all the next level PDs connect to this PSE will be power cycling whenever PD Alive Check function takes effect on 'Reset' or 'Both' Action."
],
null,
null,
null,
null
]
}- D-Link official switch MIBs
· Publisher's source file: Source package: DGS3130_RUN_1.12.B002_mibs.tar.bz2
Module: DLINKES-POE-MIB
See published definition above
· Download DLINKES-POE-MIB.myModule imports
{'SNMPv2-TC': ['DisplayString', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['PortList', 'VlanId'], 'DLINK-ID-REC-MIB': ['dlinkCommon'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'POWER-ETHERNET-MIB': ['pethMainPseGroupIndex', 'pethPsePortIndex', 'pethPsePortShortCounter', 'pethPsePortOverLoadCounter', 'pethPsePortPowerDeniedCounter']}Related source files and packages:
- MIB package: DGS3130_RUN_1.12.B002_mibs.tar.bz2
- MIB package: DGS3130_RUN_1.12.B002_mibs.tar.bz2
- MIB package: DGS3130_RUN_1.12.B002_mibs.tar.bz2
Show all 6 related files and packages
Same file in DGS3130_RUN_1.12.B002_mibs.tar.bz2.
Same file in DGS3130_RUN_1.12.B002_mibs.tar.bz2.
Same file in DGS3130_RUN_1.12.B002_mibs.tar.bz2.
Same file in DGS3130_RUN_1.12.B002_mibs.tar.bz2.
- D-Link official switch MIBs
· Publisher's source file: Source package: DGS3130_RUN_2.04.001_mibs.tar.bz2
Module: DLINKES-POE-MIB
· Download DLINKES-POE-MIB.myModule imports
{'SNMPv2-TC': ['DisplayString', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['PortList', 'VlanId'], 'DLINK-ID-REC-MIB': ['dlinkCommon'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'POWER-ETHERNET-MIB': ['pethMainPseGroupIndex', 'pethPsePortIndex', 'pethPsePortShortCounter', 'pethPsePortOverLoadCounter', 'pethPsePortPowerDeniedCounter']}Related source files and packages:
- MIB package: 2.00.011_MIB.7z
- MIB package: DGS3130_RUN_2.04.001_mibs.tar.bz2
- MIB package: DGS3130_RUN_2.04.001_mibs.tar.bz2
Show all 11 related files and packages
- MIB package: DGS3130_RUN_2.04.001_mibs.tar.bz2
- MIB package: DGS3130_RUN_2.00.011_mibs.tar.bz2
- MIB package: DGS3130_RUN_2.00.011_mibs.tar.bz2
- MIB package: 2.00.011_MIB.7z
- MIB package: DGS3130_RUN_2.04.001_mibs.tar.bz2
- MIB package: DGS3130_RUN_2.04.001_mibs.tar.bz2
- MIB package: DGS3130_RUN_2.04.001_mibs.tar.bz2
- MIB package: DGS3130_RUN_2.04.001_mibs.tar.bz2
Same file in DGS3130_RUN_2.04.001_mibs.tar.bz2.
Same file in DGS3130_RUN_2.00.011_mibs.tar.bz2.
Same file in DGS3130_RUN_2.04.001_mibs.tar.bz2.
Same file in 2.00.011_MIB.7z.
- D-Link official switch MIBs
· Publisher's source file: Source package: DMS3130_RUN_1.00.015_mibs.tar.bz2
Module: DLINKES-POE-MIB
· Download DLINKES-POE-MIB.myModule imports
{'SNMPv2-TC': ['DisplayString', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'MODULE-COMPLIANCE', 'NOTIFICATION-GROUP'], 'Q-BRIDGE-MIB': ['PortList', 'VlanId'], 'DLINK-ID-REC-MIB': ['dlinkCommon'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'POWER-ETHERNET-MIB': ['pethMainPseGroupIndex', 'pethPsePortIndex', 'pethPsePortShortCounter', 'pethPsePortOverLoadCounter', 'pethPsePortPowerDeniedCounter']}Related source files and packages:
- MIB package: DMS_DXS3130_RUN_1.30.006_mibs.tar.bz2
- MIB package: DMS_DXS3130_RUN_1.30.006_mibs.tar.bz2
- MIB package: DMS_DXS3130_RUN_1.30.006_mibs.tar.bz2
Show all 9 related files and packages
- MIB package: DMS_DXS3130_RUN_1.20.003_mibs.tar.bz2
- MIB package: DMS_DXS3130_RUN_1.20.003_mibs.tar.bz2
- MIB package: DMS_DXS3130_RUN_1.20.003_mibs.tar.bz2
- MIB package: DMS3130_RUN_1.00.015_mibs.tar.bz2
- MIB package: DMS_DXS3130_RUN_1.30.006_mibs.tar.bz2
- MIB package: DMS_DXS3130_RUN_1.30.006_mibs.tar.bz2
Same file in DMS_DXS3130_RUN_1.30.006_mibs.tar.bz2.
Same file in DMS_DXS3130_RUN_1.20.003_mibs.tar.bz2.
Same file in DMS_DXS3130_RUN_1.30.006_mibs.tar.bz2.
Same file in DMS_DXS3130_RUN_1.30.006_mibs.tar.bz2.
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.171)
Direct children (1)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.17.24.1.3.3.1 | esPoeIfPdAliveCfgEntry | 8 | 8 |
Siblings (2)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.17.24.1.3.1 | esPoeIfCfgTable | 1 | 5 | |
| 1.3.6.1.4.1.171.17.24.1.3.2 | esPoeIfInfoObjects | 3 | 21 |