The maximum number of seconds between successive samples of the counters associated with this data source. A sampling interval of 0 disables counter sampling. The agent is permitted to have minimum and maximum allowable values for the counter polling interval. A minimum interval lets the agent designer set an upper bound on the overhead associated with polling, and a maximum interval may be the result of implementation restrictions (such as counter size). In addition not all values between the maximum and minimum may be realizable as the sampling interval (again because of implementation considerations). When the sampling rate is set the agent is free to adjust the value so that it lies between the maximum and minimum values and has the closest achievable value. When read, the agent must return the actual sampling interval it will be using (after the adjustments previously described). The sampling algorithm must converge so that over time the number of packets sampled approaches 1/Nth of the total number of packets in the monitored flows.
OID reference
sFlowCpInterval
1.3.6.1.4.1.171.9.255.1.6.1.4
Description
The maximum number of seconds between successive samples of the counters associated with this data source. A sampling interval of 0 disables counter sampling. The agent is permitted to have minimum and maximum allowable values for the counter polling interval. A minimum interval lets the agent designer set an upper bo…
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.171.9.255.1.6.1 (sFlowCpEntry)
- Node code
- 4
- Node name
- sFlowCpInterval
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.171.9.255.1.6.1.4
- URN notation
- urn:oid:1.3.6.1.4.1.171.9.255.1.6.1.4
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 171 9 255 1 6 1 4}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dlink(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) d-link(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) company(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) my(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nms(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dlink(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) d-link(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) company(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) my(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nms(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dlink(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) d-link(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) company(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) my(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) nms(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dlink(171) nmsMgmt(9) sFlowMIB(255) sFlowAgent(1) sFlowCpTable(6) sFlowCpEntry(1) sFlowCpInterval(4)}
- Additional combinations skipped.
- OID-IRI notation
- /1/3/6/1/4/1/171/9/255/1/6/1/4
- /ISO/Identified-Organization/6/1/4/1/171/9/255/1/6/1/4
- /ISO/3/6/1/4/1/171/9/255/1/6/1/4
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/dlink/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/enterprise/d-link/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/enterprise/company/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/enterprise/my/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/enterprise/nms/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/enterprises/dlink/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/enterprises/d-link/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/enterprises/company/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/enterprises/my/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/enterprises/nms/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/ldap-enterprise/dlink/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/ldap-enterprise/d-link/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/ldap-enterprise/company/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/ldap-enterprise/my/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/ldap-enterprise/nms/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- /iso/identified-organization/dod/internet/private/vendor-objects/dlink/nmsMgmt/sFlowMIB/sFlowAgent/sFlowCpTable/sFlowCpEntry/sFlowCpInterval
- Additional combinations skipped.
SNMP properties
- Value type
- Integer32
- Maximum access defined by MIB
- read-write
- Status in MIB
- current
- Default value
- 0
Using this OID with SNMP
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: sFlowCpDataSource, sFlowCpInstance.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.171.9.255.1.6.1.4
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
sFlowCpInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of seconds between successive samples of the
counters associated with this data source. A sampling interval
of 0 disables counter sampling.
The agent is permitted to have minimum and maximum allowable
values for the counter polling interval. A minimum interval
lets the agent designer set an upper bound on the overhead
associated with polling, and a maximum interval may be the
result of implementation restrictions (such as counter size).
In addition not all values between the maximum and minimum may
be realizable as the sampling interval (again because of
implementation considerations).
When the sampling rate is set the agent is free to adjust the
value so that it lies between the maximum and minimum values
and has the closest achievable value.
When read, the agent must return the actual sampling interval
it will be using (after the adjustments previously described).
The sampling algorithm must converge so that over time the
number of packets sampled approaches 1/Nth of the total number
of packets in the monitored flows."
DEFVAL { 0 }
::= { sFlowCpEntry 4 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Records for description 1D-Link official switch MIBs
sFlowCpInterval · currentD-Link official switch MIBs
Status in source: current.
Names: sFlowCpInterval
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"sFlowCpInterval",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"The maximum number of seconds between successive samples of the counters associated with this data source. A sampling interval of 0 disables counter sampling. The agent is permitted to have minimum and maximum allowable values for the counter polling interval. A minimum interval lets the agent designer set an upper bound on the overhead associated with polling, and a maximum interval may be the result of implementation restrictions (such as counter size). In addition not all values between the maximum and minimum may be realizable as the sampling interval (again because of implementation considerations). When the sampling rate is set the agent is free to adjust the value so that it lies between the maximum and minimum values and has the closest achievable value. When read, the agent must return the actual sampling interval it will be using (after the adjustments previously described). The sampling algorithm must converge so that over time the number of packets sampled approaches 1/Nth of the total number of packets in the monitored flows.\"",
"DEFVAL",
"{",
"0",
"}",
"::=",
"{",
"sFlowCpEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The maximum number of seconds between successive samples of the counters associated with this data source. A sampling interval of 0 disables counter sampling. The agent is permitted to have minimum and maximum allowable values for the counter polling interval. A minimum interval lets the agent designer set an upper bound on the overhead associated with polling, and a maximum interval may be the result of implementation restrictions (such as counter size). In addition not all values between the maximum and minimum may be realizable as the sampling interval (again because of implementation considerations). When the sampling rate is set the agent is free to adjust the value so that it lies between the maximum and minimum values and has the closest achievable value. When read, the agent must return the actual sampling interval it will be using (after the adjustments previously described). The sampling algorithm must converge so that over time the number of packets sampled approaches 1/Nth of the total number of packets in the monitored flows."
],
null,
null,
null,
[
"DEFVAL",
0
]
]
}- D-Link official switch MIBs
· Publisher's source file: Source package: Private MIB.zip
Module: NMS-SFLOW-MIB
See published definition above
· Download NMS-SFLOW-MIB.myModule imports
{'NMS-SMI': ['nmsMgmt'], 'RMON-MIB': ['OwnerString'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'enterprises'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}Related source files and packages:
Show more related files and packages
Same file in Private MIB.zip.
Same file in Private MIB.zip.
Same file in Private MIB.zip.
Same file in Private MIB.zip.
Registration
Registration authorities
First Registration Authority (inferred from ancestor 1.3.6.1.4.1.171)
Siblings (3)
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.171.9.255.1.6.1.1 | sFlowCpDataSource | 0 | 0 | |
| 1.3.6.1.4.1.171.9.255.1.6.1.2 | sFlowCpInstance | 0 | 0 | |
| 1.3.6.1.4.1.171.9.255.1.6.1.3 | sFlowCpReceiver | 0 | 0 |