luDevStatus

1.3.6.1.4.1.1714.1.9.1.13

Description

Logical unit device status flags Power Supply: BIT 0 - CLEAR: Power supply functioning normally. SET: Power supply malfunctioning. BITS 1-5 - Reserved (Set to 0). BIT 6 - CLEAR: Power supply is ON. SET: Power supply is OFF. BIT 7 - CLEAR: Power supply IS present. SET: Power supply is NOT present. == 0xff - Status unkn…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1714.1.9.1 (luDevEntry)
Node code
13
Node name
luDevStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1714.1.9.1.13
URN notation
urn:oid:1.3.6.1.4.1.1714.1.9.1.13
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1714 1 9 1 13}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) infortrend(1714) extInterface(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) infortrend(1714) raid(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) infortrend(1714) extInterface(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) infortrend(1714) raid(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) infortrend(1714) extInterface(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) infortrend(1714) raid(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) infortrend(1714) extInterface(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) infortrend(1714) raid(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) infortrend(1714) extInterface(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) infortrend(1714) raid(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) infortrend(1714) extInterface(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) infortrend(1714) raid(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) infortrend(1714) extInterface(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) infortrend(1714) raid(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) infortrend(1714) extInterface(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) infortrend(1714) raid(1) luDevTable(9) luDevEntry(1) luDevStatus(13)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1714/1/9/1/13
  • /ISO/Identified-Organization/6/1/4/1/1714/1/9/1/13
  • /ISO/3/6/1/4/1/1714/1/9/1/13
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/infortrend/extInterface/luDevTable/luDevEntry/luDevStatus
  • /iso/identified-organization/dod/internet/private/enterprise/infortrend/raid/luDevTable/luDevEntry/luDevStatus
  • /iso/identified-organization/dod/internet/private/enterprises/infortrend/extInterface/luDevTable/luDevEntry/luDevStatus
  • /iso/identified-organization/dod/internet/private/enterprises/infortrend/raid/luDevTable/luDevEntry/luDevStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/infortrend/extInterface/luDevTable/luDevEntry/luDevStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/infortrend/raid/luDevTable/luDevEntry/luDevStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/infortrend/extInterface/luDevTable/luDevEntry/luDevStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/infortrend/raid/luDevTable/luDevEntry/luDevStatus
  • /iso/org/dod/internet/private/enterprise/infortrend/extInterface/luDevTable/luDevEntry/luDevStatus
  • /iso/org/dod/internet/private/enterprise/infortrend/raid/luDevTable/luDevEntry/luDevStatus
  • /iso/org/dod/internet/private/enterprises/infortrend/extInterface/luDevTable/luDevEntry/luDevStatus
  • /iso/org/dod/internet/private/enterprises/infortrend/raid/luDevTable/luDevEntry/luDevStatus
  • /iso/org/dod/internet/private/ldap-enterprise/infortrend/extInterface/luDevTable/luDevEntry/luDevStatus
  • /iso/org/dod/internet/private/ldap-enterprise/infortrend/raid/luDevTable/luDevEntry/luDevStatus
  • /iso/org/dod/internet/private/vendor-objects/infortrend/extInterface/luDevTable/luDevEntry/luDevStatus
  • /iso/org/dod/internet/private/vendor-objects/infortrend/raid/luDevTable/luDevEntry/luDevStatus
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Maximum access defined by MIB
read-only
Status in MIB
current

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In IFT-SNMP-MIB, the row index luDevTabIdx is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.1714.1.9.1.13.<luDevTabIdx>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.1714.1.9.1.13

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Logical unit device status flags
Power Supply:
BIT 0 - CLEAR: Power supply functioning normally.
SET: Power supply malfunctioning.
BITS 1-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Power supply is ON.
SET: Power supply is OFF.
BIT 7 - CLEAR: Power supply IS present.
SET: Power supply is NOT present.
== 0xff - Status unknown.
Fan:
BIT 0 - CLEAR: Fan functioning normally.
SET: Fan malfunctioning.
BITS 1-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Fan is ON.
SET: Fan is OFF.
BIT 7 - CLEAR: Fan IS present.
SET: Fan is NOT present.
== 0xff - Status unknown.
Temperature Sensor:
BIT 0 - CLEAR: Temp. sensor functioning normally.
SET: Temp. sensor malfunctioning.
BIT 1 - 3: If == 0, Temp. within safe range.
If == 2, Cold Temp. Warning.
If == 3, Hot Temp. Warning.
If == 4, Cold Temp. Limit Exceeded.
If == 5, Hot Temp. Limit Exceeded.
BIT 6 - CLEAR: Temp. Sensor is Activated.
SET: Temp. Sensor is NOT Activated.
BIT 7 - CLEAR: Temperature sensor IS present.
SET: Temperature sensor is NOT present.
== 0xff - Status unknown.
UPS:
BIT 0 - CLEAR: Unit functioning normally.
SET: Unit malfunctioning.
BIT 1 - CLEAR: AC Power present.
SET: AC Power NOT present.
BIT 2 - 3: If == 0, battery fully charged.
If == 1, battery not fully charged.
If == 2, battery charge critically low.
If == 3, battery completely drained.
BITS 4-5 - Reserved (Set to 0).
BIT 6 - CLEAR: UPS is ON.
SET: UPS is OFF.
BIT 7 - CLEAR: UPS IS present.
SET: UPS is NOT present.
== 0xff - Status unknown.
Battery:
BIT 0 - CLEAR: Battery functioning normally.
SET: Battery malfunctioning.
BIT 1 - CLEAR: Battery charging OFF (or trickle).
SET: Battery charging ON.
BIT 2 - 3: If == 0, battery fully charged.
If == 1, battery not fully charged.
If == 2, battery charge critically low.
If == 3, battery completely drained.
BITS 4-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Battery-backup is enabled.
SET: Battery-backup is disabled.
BIT 7 - CLEAR: Battery IS present.
SET: Battery is NOT present.
== 0xff - Status unknown.
Voltage Sensor:
BIT 0 - CLEAR: Voltage sensor functioning normally.
SET: Voltage sensor malfunctioning.
BIT 1 - 3: Current Voltage Sensor State:
If == 0, Voltage within acceptable range.
If == 2, Low Voltage Warning.
If == 3, High Voltage Warning.
If == 4, Low Voltage Limit Exceeded.
If == 5, High Voltage Limit Exceeded.
BIT 4 - 5: Reserved.
BIT 6 - CLEAR: Voltage Sensor is Activated.
SET: Voltage Sensor is NOT Activated.
BIT 7 - CLEAR: Voltage sensor IS present.
SET: Voltage sensor is NOT present.
== 0xff - Voltage Sensor Status unknown.
Current Sensor:
BIT 0 - CLEAR: Current sensor functioning normally.
SET: Current sensor malfunctioning.
BIT 1 - 3: Current Current Sensor State:
If == 0, Current within acceptable range.
If == 3, Over Current Warning.
If == 5, Over Current Limit Exceeded.
BIT 4 - 5: Reserved.
BIT 6 - CLEAR: Current Sensor is Activated.
SET: Current Sensor is NOT Activated.
BIT 7 - CLEAR: Current sensor IS present.
SET: Current sensor is NOT present.
== 0xff - Current Sensor Status unknown.
Door:
BIT 0 - CLEAR: Door OK.
SET: Door, door lock, or door sensor malfunctioning.
BIT 1 - CLEAR: Door is shut.
SET: Door is open.
BITS 2-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Door lock engaged.
SET: Door lock NOT engaged.
BIT 7 - CLEAR: Door IS present.
SET: Door is NOT present.
== 0xff - Status unknown.
Speaker:
BIT 0 - CLEAR: Speaker functioning normally.
SET: Speaker malfunctioning.
BITS 1-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Speaker is ON.
SET: Speaker is OFF.
BIT 7 - CLEAR: Speaker IS present.
SET: Speaker is NOT present.
== 0xff - Status unknown.
Slot:
BIT 0 - CLEAR: Slot sense circuitry functioning normally.
SET: Slot sense circuitry malfunctioning.
BIT 1 - CLEAR: Device in slot has not been marked
'needing replacement' or a replacement
drive has been inserted.
SET: Device in slot has been marked BAD
and is awaiting replacement.
BIT 2 - CLEAR: Slot is activated so that drive can be accessed.
SET: Slot NOT activated.
BITS 3-5 - Reserved (Set to 0).
BIT 6 - CLEAR: Slot is NOT ready for insertion/removal.
SET: Slot is ready for insertion/removal.
BIT 7 - CLEAR: Device inserted in slot.
SET: Slot is empty.
== 0xff - Status unknown.
Sources for this description

Circitor

Parsed from IFT-SNMP-MIB.mib · IFT-SNMP-MIB

Source file: Download IFT-SNMP-MIB.mib

Browse all files from Circitor

Historical records

Additional source information

Information from OID Repository
Vendor: Infortrend Technology, Inc.
Module: IFT-SNMP-MIB

[Automatically extracted from oidview.com]
Information from Circitor
luDevStatus OBJECT-TYPE
    SYNTAX	Integer32
    MAX-ACCESS	read-only
    STATUS	current
    DESCRIPTION "Logical unit device status flags
				Power Supply:
					BIT 0 - CLEAR:	Power supply functioning normally.
							SET:	Power supply malfunctioning.
					BITS 1-5 - Reserved (Set to 0).
					BIT 6 - CLEAR:	Power supply is ON.
							SET:	Power supply is OFF.
					BIT 7 - CLEAR:	Power supply IS present.
							SET:	Power supply is NOT present.
					== 0xff - Status unknown.
				Fan:
					BIT 0 - CLEAR:	Fan functioning normally.
							SET:	Fan malfunctioning.
					BITS 1-5 - Reserved (Set to 0).
					BIT 6 - CLEAR:	Fan is ON.
							SET:	Fan is OFF.
					BIT 7 - CLEAR:	Fan IS present.
							SET:	Fan is NOT present.
					== 0xff - Status unknown.
				Temperature Sensor:
					BIT 0 - CLEAR:	Temp. sensor functioning normally.
							SET:	Temp. sensor malfunctioning.
					BIT 1 - 3: If == 0, Temp. within safe range.
							   If == 2, Cold Temp. Warning.
							   If == 3, Hot Temp. Warning.
							   If == 4, Cold Temp. Limit Exceeded.
							   If == 5, Hot Temp. Limit Exceeded.
					BIT 6 - CLEAR:	Temp. Sensor is Activated.
							SET:	Temp. Sensor is NOT Activated.
					BIT 7 - CLEAR:	Temperature sensor IS present.
							SET:	Temperature sensor is NOT present.
					== 0xff - Status unknown.
				UPS:
					BIT 0 - CLEAR:	Unit functioning normally.
							SET:	Unit malfunctioning.
					BIT 1 - CLEAR:	AC Power present.
							SET:	AC Power NOT present.
					BIT 2 - 3: If == 0, battery fully charged.
							   If == 1, battery not fully charged.
							   If == 2, battery charge critically low.
							   If == 3, battery completely drained.
					BITS 4-5 - Reserved (Set to 0).
					BIT 6 - CLEAR:	UPS is ON.
							SET:	UPS is OFF.
					BIT 7 - CLEAR:	UPS IS present.
							SET:	UPS is NOT present.
					== 0xff - Status unknown.
				Battery:
					BIT 0 - CLEAR:	Battery functioning normally.
							SET:	Battery malfunctioning.
					BIT 1 - CLEAR:	Battery charging OFF (or trickle).
							SET:	Battery charging ON.
					BIT 2 - 3: If == 0, battery fully charged.
							   If == 1, battery not fully charged.
							   If == 2, battery charge critically low.
							   If == 3, battery completely drained.
					BITS 4-5 - Reserved (Set to 0).
					BIT 6 - CLEAR:	Battery-backup is enabled.
							SET:	Battery-backup is disabled.
					BIT 7 - CLEAR:	Battery IS present.
							SET:	Battery is NOT present.
					== 0xff - Status unknown.
				Voltage Sensor:
					BIT 0 - CLEAR:	Voltage sensor functioning normally.
							SET:	Voltage sensor malfunctioning.
					BIT 1 - 3: Current Voltage Sensor State:
							   If == 0, Voltage within acceptable range.
							   If == 2, Low Voltage Warning.
							   If == 3, High Voltage Warning.
							   If == 4, Low Voltage Limit Exceeded.
							   If == 5, High Voltage Limit Exceeded.
					BIT 4 - 5: Reserved.
					BIT 6 - CLEAR:	Voltage Sensor is Activated.
							SET:	Voltage Sensor is NOT Activated.
					BIT 7 - CLEAR:	Voltage sensor IS present.
							SET:	Voltage sensor is NOT present.
					== 0xff - Voltage Sensor Status unknown.
				Current Sensor:
					BIT 0 - CLEAR:	Current sensor functioning normally.
							SET:	Current sensor malfunctioning.
					BIT 1 - 3: Current Current Sensor State:
								If == 0, Current within acceptable range.
								If == 3, Over Current Warning.
								If == 5, Over Current Limit Exceeded.
					BIT 4 - 5: Reserved.
					BIT 6 - CLEAR:	Current Sensor is Activated.
							SET:	Current Sensor is NOT Activated.
					BIT 7 - CLEAR:	Current sensor IS present.
							SET:	Current sensor is NOT present.
					== 0xff - Current Sensor Status unknown.
				Door:
					BIT 0 - CLEAR:	Door OK.
							SET:	Door, door lock, or door sensor	malfunctioning.
					BIT 1 - CLEAR:	Door is shut.
							SET:	Door is open.
					BITS 2-5 - Reserved (Set to 0).
					BIT 6 - CLEAR:	Door lock engaged.
							SET:	Door lock NOT engaged.
					BIT 7 - CLEAR:	Door IS present.
							SET:	Door is NOT present.
					== 0xff - Status unknown.
				Speaker:
					BIT 0 - CLEAR:	Speaker functioning normally.
							SET:	Speaker malfunctioning.
					BITS 1-5 - Reserved (Set to 0).
					BIT 6 - CLEAR:	Speaker is ON.
							SET:	Speaker is OFF.
					BIT 7 - CLEAR:	Speaker IS present.
							SET:	Speaker is NOT present.
					== 0xff - Status unknown.
				Slot:
					BIT 0 - CLEAR:	Slot sense circuitry functioning normally.
							SET:	Slot sense circuitry malfunctioning.
					BIT 1 - CLEAR:	Device in slot has not been marked
									'needing replacement' or a replacement
									drive has been inserted.
							SET:	Device in slot has been marked BAD
									and is awaiting replacement.
					BIT 2 - CLEAR:	Slot is activated so that drive can	be accessed.
							SET:	Slot NOT activated.
					BITS 3-5 - Reserved (Set to 0).
					BIT 6 - CLEAR:	Slot is NOT ready for insertion/removal.
							SET:	Slot is ready for insertion/removal.
					BIT 7 - CLEAR:	Device inserted in slot.
							SET:	Slot is empty.
					== 0xff - Status unknown."
    ::= { luDevEntry 13 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1714)

Schnapp Michael

Siblings (12)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1714.1.9.1.1 luDevTabIdx00 Logical unit device table index
1.3.6.1.4.1.1714.1.9.1.2 luDescriptor00
1.3.6.1.4.1.1714.1.9.1.3 luClassCode00
1.3.6.1.4.1.1714.1.9.1.4 luTypeCode00
1.3.6.1.4.1.1714.1.9.1.5 luDevDescriptor00 Logical unit device descriptor
1.3.6.1.4.1.1714.1.9.1.6 luDevTypeCode00 Logical unit device type code
Enclosure Unit Device Types:
1 - Power supply.
2 - Fan.
3 - Temperature sensor.
4 - UPS.
5 - Voltage se…
1.3.6.1.4.1.1714.1.9.1.7 luDevIndex00 Logical unit device index
Can be used to identify device position.
If == 0, Index Not Available. For SAF-TE Logical
Units, this in…
1.3.6.1.4.1.1714.1.9.1.8 luDevDescription00 Logical unit device description string
1.3.6.1.4.1.1714.1.9.1.9 luDevValue00 Logical unit device value
1.3.6.1.4.1.1714.1.9.1.10 luDevValueUnit00 Logical unit device value unit
Fan: in RPM
Voltage Sensor: in Millivolt
Current Sensor: in Milliamps
Temperature Sensor: in 1/1000 …
1.3.6.1.4.1.1714.1.9.1.11 luDevChlNum00 Logical unit device(device slot) channel number
1.3.6.1.4.1.1714.1.9.1.12 luDevIDNum00 Logical unit device(device slot) id number