OID reference

encapInactiveTrap

1.3.6.1.4.1.177.3.0.31

Description

This trap is sent when frame relay encapsulation is turned off for a PVC.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.177.3.0 (0)
Node code
31
Node name
encapInactiveTrap
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.177.3.0.31
URN notation
urn:oid:1.3.6.1.4.1.177.3.0.31
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 177 3 0 31}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) net(177) frx(3) 0 encapInactiveTrap(31)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) net(177) frx(3) 0 encapInactiveTrap(31)}
OID-IRI notation
  • /1/3/6/1/4/1/177/3/0/31
  • /ISO/Identified-Organization/6/1/4/1/177/3/0/31
  • /ISO/3/6/1/4/1/177/3/0/31
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/net/frx/0/encapInactiveTrap
  • /iso/identified-organization/dod/internet/private/enterprises/net/frx/0/encapInactiveTrap
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/net/frx/0/encapInactiveTrap
  • /iso/identified-organization/dod/internet/private/vendor-objects/net/frx/0/encapInactiveTrap
  • /iso/org/dod/internet/private/enterprise/net/frx/0/encapInactiveTrap
  • /iso/org/dod/internet/private/enterprises/net/frx/0/encapInactiveTrap
  • /iso/org/dod/internet/private/ldap-enterprise/net/frx/0/encapInactiveTrap
  • /iso/org/dod/internet/private/vendor-objects/net/frx/0/encapInactiveTrap
  • /iso/iso-identified-organization/dod/internet/private/enterprise/net/frx/0/encapInactiveTrap
  • /iso/iso-identified-organization/dod/internet/private/enterprises/net/frx/0/encapInactiveTrap
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/net/frx/0/encapInactiveTrap
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/net/frx/0/encapInactiveTrap
  • /iso/iso-organization/dod/internet/private/enterprise/net/frx/0/encapInactiveTrap
  • /iso/iso-organization/dod/internet/private/enterprises/net/frx/0/encapInactiveTrap
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/net/frx/0/encapInactiveTrap
  • /iso/iso-organization/dod/internet/private/vendor-objects/net/frx/0/encapInactiveTrap

Available source records contain 2 distinct definitions; some records may not include a definition.

Show 2 published definitions

encapInactiveTrap · unspecified

encapInactiveTrap					TRAP-TYPE
	ENTERPRISE		frx
	DESCRIPTION
		"This trap is sent when frame relay encapsulation is
		 turned off for a PVC." 
	::= 31

encapInactiveTrap · unspecified

encapInactiveTrap					TRAP-TYPE
	ENTERPRISE		frx
	DESCRIPTION
		"This trap is sent when frame relay encapsulation is
		 turned off for a PVC." 
	::= 31

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This trap is sent when frame relay encapsulation is turned off for a PVC.

Sources for this description

CircitorMIBdepot

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Circitor, MIBdepot1 record · 2 sources

Description 1

encapInactiveTrap · unspecifiedCircitor, MIBdepot2 sources

Status in source: unspecified.

Names: encapInactiveTrap

Technical details
{
  "smi_kind": "TRAP-TYPE",
  "definition": [
    "encapInactiveTrap",
    "TRAP-TYPE",
    "ENTERPRISE",
    "frx",
    "DESCRIPTION",
    "\"This trap is sent when frame relay encapsulation is turned off for a PVC.\"",
    "::=",
    "31"
  ],
  "syntax_tree": [
    [
      "objectIdentifier",
      [
        "frx"
      ]
    ],
    [],
    [
      "DESCRIPTION",
      "This trap is sent when frame relay encapsulation is turned off for a PVC."
    ],
    null
  ]
}
  • Preserved mibdepot archive

    Module: FRX-MIB

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['Counter', 'enterprises', 'Gauge', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}
    · Download net_frx30101.mib.txt
  • Preserved circitor archive

    Module: FRX-MIB

    See published definition above

    Module imports
    {'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'RFC1155-SMI': ['Counter', 'enterprises', 'Gauge', 'IpAddress'], 'RFC1213-MIB': ['DisplayString']}
    · Download FRX-MIB.mib

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.177)

hartsell@net.com

Siblings (74)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.177.3.0.1 systemRestartTrap00
1.3.6.1.4.1.177.3.0.2 systemSyserrTrap00
1.3.6.1.4.1.177.3.0.3 configChangedTrap00
1.3.6.1.4.1.177.3.0.4 nodeCongestedTrap00
1.3.6.1.4.1.177.3.0.5 portInstalledTrap00
1.3.6.1.4.1.177.3.0.6 portDeletedTrap00
1.3.6.1.4.1.177.3.0.7 portActivatedTrap00
1.3.6.1.4.1.177.3.0.8 portDisabledTrap00
1.3.6.1.4.1.177.3.0.9 portCongestedTrap00
1.3.6.1.4.1.177.3.0.10 pvcInstalledTrap00
1.3.6.1.4.1.177.3.0.11 pvcDeletedTrap00
1.3.6.1.4.1.177.3.0.12 pvcActivatedTrap00
1.3.6.1.4.1.177.3.0.13 pvcDisabledTrap00
1.3.6.1.4.1.177.3.0.14 pvcStatusActiveTrap00
1.3.6.1.4.1.177.3.0.15 pvcStatusInactiveTrap00
1.3.6.1.4.1.177.3.0.16 cbusUpTrap00
1.3.6.1.4.1.177.3.0.17 cbusDownTrap00
1.3.6.1.4.1.177.3.0.18 serialFailTrap00
1.3.6.1.4.1.177.3.0.19 portUniActiveTrap00
1.3.6.1.4.1.177.3.0.20 portUniInactiveTrap00
1.3.6.1.4.1.177.3.0.21 portIDNXCallUpTrap00
1.3.6.1.4.1.177.3.0.22 portIDNXCallDownTrap00
1.3.6.1.4.1.177.3.0.23 nodeNotCongestedTrap00
1.3.6.1.4.1.177.3.0.24 portNotCongestedTrap00
1.3.6.1.4.1.177.3.0.25 operatorResetTrap00
1.3.6.1.4.1.177.3.0.26 eventLogClearedTrap00
1.3.6.1.4.1.177.3.0.27 configClearedTrap00
1.3.6.1.4.1.177.3.0.28 functionMismatchTrap00
1.3.6.1.4.1.177.3.0.29 eventLogErrorTrap00
1.3.6.1.4.1.177.3.0.30 encapActiveTrap00
1.3.6.1.4.1.177.3.0.32 altPathUsedTrap00
1.3.6.1.4.1.177.3.0.33 pvcStateIdleTrap00
1.3.6.1.4.1.177.3.0.34 pvcStateSetupTrap00
1.3.6.1.4.1.177.3.0.35 pvcStateCompleteTrap00
1.3.6.1.4.1.177.3.0.36 pvcStateDisconnectTrap00
1.3.6.1.4.1.177.3.0.37 billingDownloadSuccessTrap00
1.3.6.1.4.1.177.3.0.38 billingDownloadFailureTrap00
1.3.6.1.4.1.177.3.0.39 billingDownloadThresholdTrap00
1.3.6.1.4.1.177.3.0.40 configSyntaxErrorTrap00
1.3.6.1.4.1.177.3.0.41 configDownloadSuccessTrap00
1.3.6.1.4.1.177.3.0.42 configDownloadFailureTrap00
1.3.6.1.4.1.177.3.0.50 nodeFlashMemErr00
1.3.6.1.4.1.177.3.0.51 nodeFlashWriteErr00
1.3.6.1.4.1.177.3.0.52 nodeUserLogin00
1.3.6.1.4.1.177.3.0.53 nodeUserLogout00
1.3.6.1.4.1.177.3.0.54 dsx1NoAlarm00
1.3.6.1.4.1.177.3.0.55 dsx1RcvFarEndLOF00
1.3.6.1.4.1.177.3.0.56 dsx1RcvFarEndLOFEnded00
1.3.6.1.4.1.177.3.0.57 dsx1XmtFarEndLOF00
1.3.6.1.4.1.177.3.0.58 dsx1XmtFarEndLOFEnding00