event is forwarded to
the IDNX event log.
OID reference
1.3.6.1.4.1.177.3.6.1.1.7
Default determination of whether or not this type of event is forwarded to the IDNX event log.
Identification
{1 3 6 1 4 1 177 3 6 1 1 7}
| Value | Name |
|---|---|
| 1 | false |
| 2 | true |
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In FRX-MIB, the row index eventTypeIndex is declared as INTEGER. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.177.3.6.1.1.7.<eventTypeIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
Published row index: eventTypeIndex.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.177.3.6.1.1.7
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Historical records
eventTypeDefaultForward OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Default determination of whether or not this type of
event is forwarded to
the IDNX event log."
::= { eventTypeEntry 7 }
eventTypeDefaultForward OBJECT-TYPE
SYNTAX INTEGER {
false(1),
true(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Default determination of whether or not this type of
event is forwarded to
the IDNX event log."
::= { eventTypeEntry 7 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.177.3.6.1.1.1 | eventTypeIndex | 0 | 0 | Auxiliary variable used to identify row instances in the eventTypeTable. |
| 1.3.6.1.4.1.177.3.6.1.1.2 | eventTypeLevel | 0 | 0 | The IDNX alarm level of this FRX event; user configurable. |
| 1.3.6.1.4.1.177.3.6.1.1.3 | eventTypeDefaultLevel | 0 | 0 | The default IDNX alarm level of this FRX event. |
| 1.3.6.1.4.1.177.3.6.1.1.4 | eventTypeNetworkSignificant | 0 | 0 | Determines whether or not this type of event is forwarded to the repository node for network-significant events. |
| 1.3.6.1.4.1.177.3.6.1.1.5 | eventTypeDefaultNetworkSignificant | 0 | 0 | Default determination of whether or not this type of event is forwarded to the repository node for network-significant events. |
| 1.3.6.1.4.1.177.3.6.1.1.6 | eventTypeForward | 0 | 0 | Determines whether or not this type of event is forwarded to the IDNX event log; user configurable. |
| 1.3.6.1.4.1.177.3.6.1.1.8 | eventTypeLog | 0 | 0 | Determines whether or not this type of event is logged to the FRX (local) event log; user configurable. |
| 1.3.6.1.4.1.177.3.6.1.1.9 | eventTypeDefaultLog | 0 | 0 | Default determination of whether or not this type of event is logged to the FRX (local) event log. |
| 1.3.6.1.4.1.177.3.6.1.1.10 | eventTypeTrap | 0 | 0 | Determines whether or not this type of event generates an SNMP trap; user configurable. |
| 1.3.6.1.4.1.177.3.6.1.1.11 | eventTypeDefaultTrap | 0 | 0 | Default determination of whether or not this type of event generates an SNMP trap. |
| 1.3.6.1.4.1.177.3.6.1.1.12 | eventTypeTrapNumber | 0 | 0 | Enterprise-specific trap number associated with this event. |