OID reference

saHpiCtrlTextState

1.3.6.1.4.1.18568.2.1.1.4.7.11.1.15

Description

This columnar object can be used to write to the text controls. To do so, first set the line number in saHpiCtrlTextLine and then write to this object. The first line of the text control is line number 1 . If less than a full line of data is written, the control will clear all spaces beyond those written on the line. …

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.18568.2.1.1.4.7.11.1 (saHpiCtrlTextEntry)
Node code
15
Node name
saHpiCtrlTextState
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.15
URN notation
urn:oid:1.3.6.1.4.1.18568.2.1.1.4.7.11.1.15
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 18568 2 1 1 4 7 11 1 15}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) saforum(18568) draft(2) hpiD(1) hpiB0101(1) hpiResources(4) hpiControl(7) saHpiCtrlTextTable(11) saHpiCtrlTextEntry(1) saHpiCtrlTextState(15)}
OID-IRI notation
  • /1/3/6/1/4/1/18568/2/1/1/4/7/11/1/15
  • /ISO/Identified-Organization/6/1/4/1/18568/2/1/1/4/7/11/1/15
  • /ISO/3/6/1/4/1/18568/2/1/1/4/7/11/1/15
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/18568/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/identified-organization/dod/internet/private/enterprise/saforum/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/identified-organization/dod/internet/private/enterprises/18568/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/identified-organization/dod/internet/private/enterprises/saforum/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/18568/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/saforum/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/identified-organization/dod/internet/private/vendor-objects/18568/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/identified-organization/dod/internet/private/vendor-objects/saforum/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/org/dod/internet/private/enterprise/18568/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/org/dod/internet/private/enterprise/saforum/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/org/dod/internet/private/enterprises/18568/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/org/dod/internet/private/enterprises/saforum/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/org/dod/internet/private/ldap-enterprise/18568/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/org/dod/internet/private/ldap-enterprise/saforum/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/org/dod/internet/private/vendor-objects/18568/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • /iso/org/dod/internet/private/vendor-objects/saforum/draft/hpiD/hpiB0101/hpiResources/hpiControl/saHpiCtrlTextTable/saHpiCtrlTextEntry/saHpiCtrlTextState
  • Additional combinations skipped.

SNMP properties

Value type
SaHpiText
Maximum access defined by MIB
read-write
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

saHpiCtrlTextState OBJECT-TYPE
        SYNTAX SaHpiText
        MAX-ACCESS read-write
        STATUS current
        DESCRIPTION
                "This columnar object can be used to write to the
                 text controls. To do so, first set the line number
                 in saHpiCtrlTextLine and then write to this object. 

                The first line of the text control is line number  1 .
                If less than a full line of data is written,
                the control will clear all spaces beyond those written
                on the line. 
                Thus writing a zero-length string will clear the
                addressed line. It is also possible to include more
                characters in the text passed in this columnar object
                than will fit on one line; in this case, the control
                will wrap to the next line (still clearing the 
                trailing characters on the last line written).
                Thus, there are two ways to write 
                multiple lines to a text control: 
                        
                  (a) set saHpiCtrlTextState repeatedly for each line, or 
                  (b) set saHpiCtrlTextState once and send more characters
                      than will fit on one line.

              An HPI SNMP Manager should not assume any cursor
              positioning  characters are available to use, but
              rather should always write full lines and allow 
              wrapping to occur. 

              When calling this  object, an HPI SNMP Manager may
              set the line number to 255; in this case, the entire
              control will be cleared, and the data will be written 
              starting on line 1. (This is different from simply
              writing at line 1, which only alters the lines written
              to.) This feature may be used to clear the entire control, 
              which can be accomplished by setting:
              saHpiCtrlTextLine = 255; saHpiCtrlState = '';

              Note that the number of lines and columns in a text
              control can be obtained from 
              the saHpiCtrlTextMaxLines and saHpiCtrlTextMaxChars. 

              Note that the saHpiCtrlTextLanguage object has the
              language setting and saHpiCtrlTextType object
              has the text type.

              Note that the SNMP errors that are returned are mapped to the
              HPI errors that could be returned (errors above the value 6
              are SNMPv2 or v3 protocol and are converted to genErr(1)
              for v1 protocol).

                 SA_ERR_HPI_ERROR               genErr(5)           
                 SA_ERR_HPI_UNSUPPORTED_API     genErr(5)           
                 SA_ERR_HPI_BUSY                genErr(5)           
                 SA_ERR_HPI_INTERNAL_ERROR      genErr(5)           
                 SA_ERR_HPI_INVALID_CMD         genErr(5)           
                 SA_ERR_HPI_TIMEOUT             genErr(5)           
                 SA_ERR_HPI_OUT_OF_SPACE        genErr(5)           
                 SA_ERR_HPI_OUT_OF_MEMORY       genErr(5)           
                 SA_ERR_HPI_INVALID_PARAMS      genErr(5)           
                 SA_ERR_HPI_INVALID_DATA        wrongValue(10)      
                 SA_ERR_HPI_NOT_PRESENT         inconsistentName(18)
                 SA_ERR_HPI_NO_RESPONSE         genErr(5)           
                 SA_ERR_HPI_DUPLICATE           genErr(5)           
                 SA_ERR_HPI_INVALID_SESSION     genErr(5)           
                 SA_ERR_HPI_INVALID_DOMAIN      inconsistentName(18)
                 SA_ERR_HPI_INVALID_RESOURCE    inconsistentName(18)
                 SA_ERR_HPI_INVALID_REQUEST     genErr(5)           
                 SA_ERR_HPI_ENTITY_NOT_PRESENT  inconsistentName(18)
                 SA_ERR_HPI_READ_ONLY           notWritable(9)      
                 SA_ERR_HPI_CAPABILITY          genErr(5)           
                 SA_ERR_HPI_UNKNOWN             genErr(5)"       
  
        REFERENCE

                "See section 7.3.2, 7.3.3. 8.7 and 8.8
                 from SAI-HPI-B.01.01 specification."
        ::= { saHpiCtrlTextEntry 15 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

This columnar object can be used to write to the text controls. To do so, first set the line number in saHpiCtrlTextLine and then write to this object. The first line of the text control is line number 1 . If less than a full line of data is written, the control will clear all spaces beyond those written on the line. Thus writing a zero-length string will clear the addressed line. It is also possible to include more characters in the text passed in this columnar object than will fit on one line; in this case, the control will wrap to the next line (still clearing the trailing characters on the last line written). Thus, there are two ways to write multiple lines to a text control: (a) set saHpiCtrlTextState repeatedly for each line, or (b) set saHpiCtrlTextState once and send more characters than will fit on one line. An HPI SNMP Manager should not assume any cursor positioning characters are available to use, but rather should always write full lines and allow wrapping to occur. When calling this object, an HPI SNMP Manager may set the line number to 255; in this case, the entire control will be cleared, and the data will be written starting on line 1. (This is different from simply writing at line 1, which only alters the lines written to.) This feature may be used to clear the entire control, which can be accomplished by setting: saHpiCtrlTextLine = 255; saHpiCtrlState = ''; Note that the number of lines and columns in a text control can be obtained from the saHpiCtrlTextMaxLines and saHpiCtrlTextMaxChars. Note that the saHpiCtrlTextLanguage object has the language setting and saHpiCtrlTextType object has the text type. Note that the SNMP errors that are returned are mapped to the HPI errors that could be returned (errors above the value 6 are SNMPv2 or v3 protocol and are converted to genErr(1) for v1 protocol). SA_ERR_HPI_ERROR genErr(5) SA_ERR_HPI_UNSUPPORTED_API genErr(5) SA_ERR_HPI_BUSY genErr(5) SA_ERR_HPI_INTERNAL_ERROR genErr(5) SA_ERR_HPI_INVALID_CMD genErr(5) SA_ERR_HPI_TIMEOUT genErr(5) SA_ERR_HPI_OUT_OF_SPACE genErr(5) SA_ERR_HPI_OUT_OF_MEMORY genErr(5) SA_ERR_HPI_INVALID_PARAMS genErr(5) SA_ERR_HPI_INVALID_DATA wrongValue(10) SA_ERR_HPI_NOT_PRESENT inconsistentName(18) SA_ERR_HPI_NO_RESPONSE genErr(5) SA_ERR_HPI_DUPLICATE genErr(5) SA_ERR_HPI_INVALID_SESSION genErr(5) SA_ERR_HPI_INVALID_DOMAIN inconsistentName(18) SA_ERR_HPI_INVALID_RESOURCE inconsistentName(18) SA_ERR_HPI_INVALID_REQUEST genErr(5) SA_ERR_HPI_ENTITY_NOT_PRESENT inconsistentName(18) SA_ERR_HPI_READ_ONLY notWritable(9) SA_ERR_HPI_CAPABILITY genErr(5) SA_ERR_HPI_UNKNOWN genErr(5)

Sources for this description

Service Availability Forum MIB copies (MibBrowser.online)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 1Service Availability Forum MIB copies (MibBrowser.online)1 record · 1 source

Description 1

saHpiCtrlTextState · currentService Availability Forum MIB copies (MibBrowser.online)1 source

Status in source: current.

Names: saHpiCtrlTextState

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "saHpiCtrlTextState",
    "OBJECT-TYPE",
    "SYNTAX",
    "SaHpiText",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This columnar object can be used to write to the text controls. To do so, first set the line number in saHpiCtrlTextLine and then write to this object. The first line of the text control is line number 1 . If less than a full line of data is written, the control will clear all spaces beyond those written on the line. Thus writing a zero-length string will clear the addressed line. It is also possible to include more characters in the text passed in this columnar object than will fit on one line; in this case, the control will wrap to the next line (still clearing the trailing characters on the last line written). Thus, there are two ways to write multiple lines to a text control: (a) set saHpiCtrlTextState repeatedly for each line, or (b) set saHpiCtrlTextState once and send more characters than will fit on one line. An HPI SNMP Manager should not assume any cursor positioning characters are available to use, but rather should always write full lines and allow wrapping to occur. When calling this object, an HPI SNMP Manager may set the line number to 255; in this case, the entire control will be cleared, and the data will be written starting on line 1. (This is different from simply writing at line 1, which only alters the lines written to.) This feature may be used to clear the entire control, which can be accomplished by setting: saHpiCtrlTextLine = 255; saHpiCtrlState = ''; Note that the number of lines and columns in a text control can be obtained from the saHpiCtrlTextMaxLines and saHpiCtrlTextMaxChars. Note that the saHpiCtrlTextLanguage object has the language setting and saHpiCtrlTextType object has the text type. Note that the SNMP errors that are returned are mapped to the HPI errors that could be returned (errors above the value 6 are SNMPv2 or v3 protocol and are converted to genErr(1) for v1 protocol). SA_ERR_HPI_ERROR genErr(5) SA_ERR_HPI_UNSUPPORTED_API genErr(5) SA_ERR_HPI_BUSY genErr(5) SA_ERR_HPI_INTERNAL_ERROR genErr(5) SA_ERR_HPI_INVALID_CMD genErr(5) SA_ERR_HPI_TIMEOUT genErr(5) SA_ERR_HPI_OUT_OF_SPACE genErr(5) SA_ERR_HPI_OUT_OF_MEMORY genErr(5) SA_ERR_HPI_INVALID_PARAMS genErr(5) SA_ERR_HPI_INVALID_DATA wrongValue(10) SA_ERR_HPI_NOT_PRESENT inconsistentName(18) SA_ERR_HPI_NO_RESPONSE genErr(5) SA_ERR_HPI_DUPLICATE genErr(5) SA_ERR_HPI_INVALID_SESSION genErr(5) SA_ERR_HPI_INVALID_DOMAIN inconsistentName(18) SA_ERR_HPI_INVALID_RESOURCE inconsistentName(18) SA_ERR_HPI_INVALID_REQUEST genErr(5) SA_ERR_HPI_ENTITY_NOT_PRESENT inconsistentName(18) SA_ERR_HPI_READ_ONLY notWritable(9) SA_ERR_HPI_CAPABILITY genErr(5) SA_ERR_HPI_UNKNOWN genErr(5)\"",
    "REFERENCE",
    "\"See section 7.3.2, 7.3.3. 8.7 and 8.8 from SAI-HPI-B.01.01 specification.\"",
    "::=",
    "{",
    "saHpiCtrlTextEntry",
    "15",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "SaHpiText"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This columnar object can be used to write to the text controls. To do so, first set the line number in saHpiCtrlTextLine and then write to this object. The first line of the text control is line number 1 . If less than a full line of data is written, the control will clear all spaces beyond those written on the line. Thus writing a zero-length string will clear the addressed line. It is also possible to include more characters in the text passed in this columnar object than will fit on one line; in this case, the control will wrap to the next line (still clearing the trailing characters on the last line written). Thus, there are two ways to write multiple lines to a text control: (a) set saHpiCtrlTextState repeatedly for each line, or (b) set saHpiCtrlTextState once and send more characters than will fit on one line. An HPI SNMP Manager should not assume any cursor positioning characters are available to use, but rather should always write full lines and allow wrapping to occur. When calling this object, an HPI SNMP Manager may set the line number to 255; in this case, the entire control will be cleared, and the data will be written starting on line 1. (This is different from simply writing at line 1, which only alters the lines written to.) This feature may be used to clear the entire control, which can be accomplished by setting: saHpiCtrlTextLine = 255; saHpiCtrlState = ''; Note that the number of lines and columns in a text control can be obtained from the saHpiCtrlTextMaxLines and saHpiCtrlTextMaxChars. Note that the saHpiCtrlTextLanguage object has the language setting and saHpiCtrlTextType object has the text type. Note that the SNMP errors that are returned are mapped to the HPI errors that could be returned (errors above the value 6 are SNMPv2 or v3 protocol and are converted to genErr(1) for v1 protocol). SA_ERR_HPI_ERROR genErr(5) SA_ERR_HPI_UNSUPPORTED_API genErr(5) SA_ERR_HPI_BUSY genErr(5) SA_ERR_HPI_INTERNAL_ERROR genErr(5) SA_ERR_HPI_INVALID_CMD genErr(5) SA_ERR_HPI_TIMEOUT genErr(5) SA_ERR_HPI_OUT_OF_SPACE genErr(5) SA_ERR_HPI_OUT_OF_MEMORY genErr(5) SA_ERR_HPI_INVALID_PARAMS genErr(5) SA_ERR_HPI_INVALID_DATA wrongValue(10) SA_ERR_HPI_NOT_PRESENT inconsistentName(18) SA_ERR_HPI_NO_RESPONSE genErr(5) SA_ERR_HPI_DUPLICATE genErr(5) SA_ERR_HPI_INVALID_SESSION genErr(5) SA_ERR_HPI_INVALID_DOMAIN inconsistentName(18) SA_ERR_HPI_INVALID_RESOURCE inconsistentName(18) SA_ERR_HPI_INVALID_REQUEST genErr(5) SA_ERR_HPI_ENTITY_NOT_PRESENT inconsistentName(18) SA_ERR_HPI_READ_ONLY notWritable(9) SA_ERR_HPI_CAPABILITY genErr(5) SA_ERR_HPI_UNKNOWN genErr(5)"
    ],
    [
      "REFERENCE",
      "See section 7.3.2, 7.3.3. 8.7 and 8.8 from SAI-HPI-B.01.01 specification."
    ],
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.18568)

Bill Swortwood

Siblings (16)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.1 saHpiCtrlTextEntryId00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.2 saHpiCtrlTextNum00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.3 saHpiCtrlTextOutputType00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.4 saHpiCtrlTextDefaultMode00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.5 saHpiCtrlTextMode00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.6 saHpiCtrlTextIsReadOnly00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.7 saHpiCtrlTextIsWriteOnly00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.8 saHpiCtrlTextMaxChars00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.9 saHpiCtrlTextMaxLines00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.10 saHpiCtrlTextLanguage00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.11 saHpiCtrlTextType00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.12 saHpiCtrlTextDefaultLine00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.13 saHpiCtrlTextDefault00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.14 saHpiCtrlTextLine00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.16 saHpiCtrlTextOem00
1.3.6.1.4.1.18568.2.1.1.4.7.11.1.17 saHpiCtrlTextRDR00