Sources for this description
Circitor
Parsed from ALTEON-ISD-PLATFORM-MIB.mib · ALTEON-ISD-PLATFORM-MIB
Source file: Download ALTEON-ISD-PLATFORM-MIB.mib
OID reference
1.3.6.1.4.1.1872.2.3.1.2.1.3.3.1.4
The alarming object.
Identification
{1 3 6 1 4 1 1872 2 3 1 2 1 3 3 1 4}
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.
In ALTEON-ISD-PLATFORM-MIB, the row index currentAlarmIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.1872.2.3.1.2.1.3.3.1.4.<currentAlarmIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.1872.2.3.1.2.1.3.3.1.4
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Parsed from ALTEON-ISD-PLATFORM-MIB.mib · ALTEON-ISD-PLATFORM-MIB
Source file: Download ALTEON-ISD-PLATFORM-MIB.mib
Historical records
currentAlarmObject OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarming object."
::= { currentAlarmEntry 4 }
currentAlarmObject OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarming object."
::= { currentAlarmEntry 4 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1872.2.3.1.2.1.3.3.1.1 | currentAlarmIndex | 0 | 0 | An id that uniquely identifies an alarm. Each active alarm is represented as one an entry in the currentAlarmTable. |
| 1.3.6.1.4.1.1872.2.3.1.2.1.3.3.1.2 | currentAlarmSeverity | 0 | 0 | The perceived severity of the fault. A manager can set this value to clear only. When set to clear, the alarm is removed from t… |
| 1.3.6.1.4.1.1872.2.3.1.2.1.3.3.1.3 | currentAlarmOid | 0 | 0 | The SNMP Notification which was sent to represent the alarm. |
| 1.3.6.1.4.1.1872.2.3.1.2.1.3.3.1.5 | currentAlarmCause | 0 | 0 | The probable cause of the alarm. |
| 1.3.6.1.4.1.1872.2.3.1.2.1.3.3.1.6 | currentAlarmTime | 0 | 0 | The time the fault was detected. |