upsBatteryVoltage

1.3.6.1.4.1.1909.10.22.10

Description

The magnitude of the present battery voltage.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1909.10.22 (ups)
Node code
10
Node name
upsBatteryVoltage
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1909.10.22.10
URN notation
urn:oid:1.3.6.1.4.1.1909.10.22.10
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1909 10 22 10}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) 1909 rms(10) ups(22) upsBatteryVoltage(10)}
OID-IRI notation
  • /1/3/6/1/4/1/1909/10/22/10
  • /ISO/Identified-Organization/6/1/4/1/1909/10/22/10
  • /ISO/3/6/1/4/1/1909/10/22/10
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1909/rms/ups/upsBatteryVoltage
  • /iso/identified-organization/dod/internet/private/enterprise/Infratec/rms/ups/upsBatteryVoltage
  • /iso/identified-organization/dod/internet/private/enterprises/1909/rms/ups/upsBatteryVoltage
  • /iso/identified-organization/dod/internet/private/enterprises/Infratec/rms/ups/upsBatteryVoltage
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1909/rms/ups/upsBatteryVoltage
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Infratec/rms/ups/upsBatteryVoltage
  • /iso/identified-organization/dod/internet/private/vendor-objects/1909/rms/ups/upsBatteryVoltage
  • /iso/identified-organization/dod/internet/private/vendor-objects/Infratec/rms/ups/upsBatteryVoltage
  • /iso/org/dod/internet/private/enterprise/1909/rms/ups/upsBatteryVoltage
  • /iso/org/dod/internet/private/enterprise/Infratec/rms/ups/upsBatteryVoltage
  • /iso/org/dod/internet/private/enterprises/1909/rms/ups/upsBatteryVoltage
  • /iso/org/dod/internet/private/enterprises/Infratec/rms/ups/upsBatteryVoltage
  • /iso/org/dod/internet/private/ldap-enterprise/1909/rms/ups/upsBatteryVoltage
  • /iso/org/dod/internet/private/ldap-enterprise/Infratec/rms/ups/upsBatteryVoltage
  • /iso/org/dod/internet/private/vendor-objects/1909/rms/ups/upsBatteryVoltage
  • /iso/org/dod/internet/private/vendor-objects/Infratec/rms/ups/upsBatteryVoltage
  • Additional combinations skipped.

SNMP properties

Value type
NonNegativeInteger
Units
0.1 Volt DC
Maximum access defined by MIB
read-only
Status in MIB
current

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

upsBatteryVoltage OBJECT-TYPE
	SYNTAX     NonNegativeInteger
	UNITS      "0.1 Volt DC"
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
		 "The magnitude of the present battery voltage."
	::= { ups 10 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The magnitude of the present battery voltage.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

upsBatteryVoltage · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: upsBatteryVoltage

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "upsBatteryVoltage",
    "OBJECT-TYPE",
    "SYNTAX",
    "NonNegativeInteger",
    "UNITS",
    [
      "literal",
      "22302e3120566f6c7420444322"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The magnitude of the present battery voltage.\"",
    "::=",
    "{",
    "ups",
    "10",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "NonNegativeInteger"
    ],
    [
      "UNITS",
      "0.1 Volt DC"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The magnitude of the present battery voltage."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1909)

Groeger Michael

Siblings (20)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1909.10.22.1 upsConnected00
1.3.6.1.4.1.1909.10.22.2 upsManufacturer00
1.3.6.1.4.1.1909.10.22.3 upsModel00
1.3.6.1.4.1.1909.10.22.4 upsFirmwareVersion00
1.3.6.1.4.1.1909.10.22.5 upsSoftwareVersion00
1.3.6.1.4.1.1909.10.22.6 upsID00
1.3.6.1.4.1.1909.10.22.7 upsBatteryLastReplaced00
1.3.6.1.4.1.1909.10.22.8 upsTimeOnBattery00
1.3.6.1.4.1.1909.10.22.9 upsTimeRemaining00
1.3.6.1.4.1.1909.10.22.11 upsBatteryCurrent00
1.3.6.1.4.1.1909.10.22.12 upsBatteryTemp00
1.3.6.1.4.1.1909.10.22.13 upsBatteryStatus00
1.3.6.1.4.1.1909.10.22.14 upsLineFrequency00
1.3.6.1.4.1.1909.10.22.15 upsLineVoltage00
1.3.6.1.4.1.1909.10.22.16 upsOutputVoltage00
1.3.6.1.4.1.1909.10.22.17 upsNominalOutputVoltage00
1.3.6.1.4.1.1909.10.22.18 upsOnline00
1.3.6.1.4.1.1909.10.22.19 upsCalibrating00
1.3.6.1.4.1.1909.10.22.20 upsSleeping00
1.3.6.1.4.1.1909.10.22.21 upsLoad00