Indicates whether or not this schedule is currently considered true or false.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.1918.2.13.10.110.40.1.10
Indicates whether or not this schedule is currently considered true or false.
Identification
{1 3 6 1 4 1 1918 2 13 10 110 40 1 10}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
smart-Alarm-Schedule-Source-Is-Triggered OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether or not this schedule is currently considered true or false."
::= { source-Schedule-Entry 10 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Indicates whether or not this schedule is currently considered true or false.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: smart-Alarm-Schedule-Source-Is-Triggered
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"smart-Alarm-Schedule-Source-Is-Triggered",
"OBJECT-TYPE",
"SYNTAX",
"Boolean",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Indicates whether or not this schedule is currently considered true or false.\"",
"::=",
"{",
"source-Schedule-Entry",
"10",
"}"
],
"syntax_tree": [
[
"row",
"Boolean"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Indicates whether or not this schedule is currently considered true or false."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: RPS-SC200-MIB
See published definition above
{'RFC-1213': ['DisplayString'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['enterprises', 'IpAddress', 'TimeTicks', 'OBJECT-TYPE', 'mib-2', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Integer32', 'Counter32']}Related source files and packages:
Same file in Observium Community.
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1918.2.13.10.110.40.1.1 | source-Schedule-Index | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.13.10.110.40.1.20 | smart-Alarm-Schedule-Source-Status | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.13.10.110.40.1.30 | smart-Alarm-Schedule-Source-Mapping | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.13.10.110.40.1.50 | smart-Alarm-Schedule-Source-First-Activation | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.13.10.110.40.1.60 | smart-Alarm-Schedule-Source-Duration | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.13.10.110.40.1.70 | smart-Alarm-Schedule-Source-Interval | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.13.10.110.40.1.80 | smart-Alarm-Schedule-Source-Repetitions | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.13.10.110.40.1.90 | smart-Alarm-Schedule-Source-Next | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.13.10.110.40.1.100 | smart-Alarm-Schedule-Source-End | 0 | 0 |