OID reference

bcl-Engine-Run-Limit

1.3.6.1.4.1.1918.2.13.10.70.50.50

Description

The Battery Current Limit setting when Engine Run is active. BCL maintains the battery current below this value when the Engine Run digital input is active (Engine Run is enabled). This limit is expressed as a percentage of the installed C10 Battery Capacity.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1918.2.13.10.70.50 (battery-Current-Limit)
Node code
50
Node name
bcl-Engine-Run-Limit
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1918.2.13.10.70.50.50
URN notation
urn:oid:1.3.6.1.4.1.1918.2.13.10.70.50.50
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1918 2 13 10 70 50 50}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eaton-chnz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eaton-chnz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eatonChNz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eatonChNz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eaton-chnz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eaton-chnz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eatonChNz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eatonChNz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eaton-chnz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eaton-chnz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eatonChNz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eatonChNz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eaton-chnz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eaton-chnz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eatonChNz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eatonChNz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) control-Functions(70) battery-Current-Limit(50) bcl-Engine-Run-Limit(50)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1918/2/13/10/70/50/50
  • /ISO/Identified-Organization/6/1/4/1/1918/2/13/10/70/50/50
  • /ISO/3/6/1/4/1/1918/2/13/10/70/50/50
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1918/dc-Power-System/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprise/1918/dcPowerSystem/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprise/eaton-chnz/dc-Power-System/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprise/eaton-chnz/dcPowerSystem/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprise/eatonChNz/dc-Power-System/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprise/eatonChNz/dcPowerSystem/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprises/1918/dc-Power-System/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprises/1918/dcPowerSystem/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprises/eaton-chnz/dc-Power-System/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprises/eaton-chnz/dcPowerSystem/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprises/eatonChNz/dc-Power-System/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/enterprises/eatonChNz/dcPowerSystem/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1918/dc-Power-System/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1918/dcPowerSystem/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/eaton-chnz/dc-Power-System/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/eaton-chnz/dcPowerSystem/rps-SC200/rps-Objects/control-Functions/battery-Current-Limit/bcl-Engine-Run-Limit
  • Additional combinations skipped.

SNMP properties

Value type
Unsigned8
Units
%
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
2

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

bcl-Engine-Run-Limit OBJECT-TYPE
  SYNTAX Unsigned8
  UNITS "%"
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION "The Battery Current Limit setting when Engine Run is active. BCL maintains the battery current below this value when the Engine Run digital input is active (Engine Run is enabled). This limit is expressed as a percentage of the installed C10 Battery Capacity."
  DEFVAL { 2 }
::= { battery-Current-Limit 50 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The Battery Current Limit setting when Engine Run is active. BCL maintains the battery current below this value when the Engine Run digital input is active (Engine Run is enabled). This limit is expressed as a percentage of the installed C10 Battery Capacity.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

bcl-Engine-Run-Limit · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: bcl-Engine-Run-Limit

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "bcl-Engine-Run-Limit",
    "OBJECT-TYPE",
    "SYNTAX",
    "Unsigned8",
    "UNITS",
    [
      "literal",
      "222522"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The Battery Current Limit setting when Engine Run is active. BCL maintains the battery current below this value when the Engine Run digital input is active (Engine Run is enabled). This limit is expressed as a percentage of the installed C10 Battery Capacity.\"",
    "DEFVAL",
    "{",
    "2",
    "}",
    "::=",
    "{",
    "battery-Current-Limit",
    "50",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "Unsigned8"
    ],
    [
      "UNITS",
      "%"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The Battery Current Limit setting when Engine Run is active. BCL maintains the battery current below this value when the Engine Run digital input is active (Engine Run is enabled). This limit is expressed as a percentage of the installed C10 Battery Capacity."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      2
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1918)

Jackson Adrian

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.1918.2.13.10.70.50.5 enable-Battery-Current-Limit00
1.3.6.1.4.1.1918.2.13.10.70.50.10 bcl-State00
1.3.6.1.4.1.1918.2.13.10.70.50.20 generator-State00
1.3.6.1.4.1.1918.2.13.10.70.50.30 bcl-Limit00
1.3.6.1.4.1.1918.2.13.10.70.50.40 bcl-Offset-Voltage00