ai-Name

1.3.6.1.4.1.1918.2.13.10.90.10.30.1.60

Description

The name of this analog input channel as it will appear on management software such as DCTools or PowerManagerII. This name is not displayed on the controller.

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.1918.2.13.10.90.10.30.1 (analog-Input-Entry)
Node code
60
Node name
ai-Name
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.1918.2.13.10.90.10.30.1.60
URN notation
urn:oid:1.3.6.1.4.1.1918.2.13.10.90.10.30.1.60
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 1918 2 13 10 90 10 30 1 60}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eaton-chnz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eaton-chnz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eatonChNz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) eatonChNz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eaton-chnz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eaton-chnz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eatonChNz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) eatonChNz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eaton-chnz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eaton-chnz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eatonChNz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) eatonChNz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eaton-chnz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eaton-chnz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eatonChNz(1918) dc-Power-System(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) eatonChNz(1918) dcPowerSystem(2) rps-SC200(13) rps-Objects(10) input-Output(90) system-Analog-Input(10) analog-Input-Table(30) analog-Input-Entry(1) ai-Name(60)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/1918/2/13/10/90/10/30/1/60
  • /ISO/Identified-Organization/6/1/4/1/1918/2/13/10/90/10/30/1/60
  • /ISO/3/6/1/4/1/1918/2/13/10/90/10/30/1/60
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/1918/dc-Power-System/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprise/1918/dcPowerSystem/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprise/eaton-chnz/dc-Power-System/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprise/eaton-chnz/dcPowerSystem/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprise/eatonChNz/dc-Power-System/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprise/eatonChNz/dcPowerSystem/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprises/1918/dc-Power-System/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprises/1918/dcPowerSystem/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprises/eaton-chnz/dc-Power-System/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprises/eaton-chnz/dcPowerSystem/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprises/eatonChNz/dc-Power-System/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/enterprises/eatonChNz/dcPowerSystem/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1918/dc-Power-System/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/1918/dcPowerSystem/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/eaton-chnz/dc-Power-System/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/eaton-chnz/dcPowerSystem/rps-SC200/rps-Objects/input-Output/system-Analog-Input/analog-Input-Table/analog-Input-Entry/ai-Name
  • Additional combinations skipped.

SNMP properties

Value type
Display-20
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
"Bus Voltage"

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

ai-Name OBJECT-TYPE
  SYNTAX Display-20
  MAX-ACCESS read-write
  STATUS current
  DESCRIPTION "The name of this analog input channel as it will appear on management software such as DCTools or PowerManagerII. This name is not displayed on the controller."
  DEFVAL { "Bus Voltage" }
::= { analog-Input-Entry 60 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The name of this analog input channel as it will appear on management software such as DCTools or PowerManagerII. This name is not displayed on the controller.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

ai-Name · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: ai-Name

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ai-Name",
    "OBJECT-TYPE",
    "SYNTAX",
    "Display-20",
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The name of this analog input channel as it will appear on management software such as DCTools or PowerManagerII. This name is not displayed on the controller.\"",
    "DEFVAL",
    "{",
    [
      "literal",
      "2242757320566f6c7461676522"
    ],
    "}",
    "::=",
    "{",
    "analog-Input-Entry",
    "60",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "Display-20"
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The name of this analog input channel as it will appear on management software such as DCTools or PowerManagerII. This name is not displayed on the controller."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      "\"Bus Voltage\""
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.1918)

Jackson Adrian

Siblings (24)