This command resets Low-Rectifier-Capacity-Alarm.
Sources for this description
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
OID reference
1.3.6.1.4.1.1918.2.14.10.110.5.117
This command resets Low-Rectifier-Capacity-Alarm.
Identification
{1 3 6 1 4 1 1918 2 14 10 110 5 117}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
The displayed source records contain one distinct definition. Compare its source records.
resetLowRectifierCapacityAlarm OBJECT-TYPE
SYNTAX NoData
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This command resets Low-Rectifier-Capacity-Alarm."
::= { alarmStates 117 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This command resets Low-Rectifier-Capacity-Alarm.
Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: resetLowRectifierCapacityAlarm
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"resetLowRectifierCapacityAlarm",
"OBJECT-TYPE",
"SYNTAX",
"NoData",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This command resets Low-Rectifier-Capacity-Alarm.\"",
"::=",
"{",
"alarmStates",
"117",
"}"
],
"syntax_tree": [
[
"row",
"NoData"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This command resets Low-Rectifier-Capacity-Alarm."
],
null,
null,
null,
null
]
}Vendor MIB copy from the LibreNMS archive.
Module: RpsSc300Mib
See published definition above
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['enterprises', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}Related source files and packages:
Vendor MIB copy from the Observium Community archive.
Module: RPS-SC300-MIB
{'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'DisplayString'], 'SNMPv2-SMI': ['enterprises', 'OBJECT-TYPE', 'MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-IDENTITY', 'Integer32', 'Unsigned32'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'OBJECT-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1918.2.14.10.110.5.10 | summaryAlarmCritical | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.14.10.110.5.20 | summaryAlarmMajor | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.14.10.110.5.30 | summaryAlarmMinor | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.14.10.110.5.100 | resetBatteryTestFailedAlarm | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.14.10.110.5.110 | resetCommsLostAlarm | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.14.10.110.5.115 | resetBatteryTestCancelledAlarm | 0 | 0 | |
| 1.3.6.1.4.1.1918.2.14.10.110.5.130 | alarmInfo | 0 | 0 |