eriRouterIcrMIBCompliance — Ericsson MIB copies (MibBrowser.online)
The compliance statement for ICR MIB implementations.
{1 3 6 1 4 1 193 218 2 101 2 1 1}
The compliance statement for ICR MIB implementations.
Status in source: current.
Names: eriRouterIcrMIBCompliance
{
"smi_kind": "MODULE-COMPLIANCE",
"definition": [
"eriRouterIcrMIBCompliance",
"MODULE-COMPLIANCE",
"STATUS",
"current",
"DESCRIPTION",
"\"The compliance statement for ICR MIB implementations.\"",
"MODULE",
"MANDATORY-GROUPS",
"{",
"eriRouterIcrGroup",
",",
"eriRouterIcrNotificationObjectGroup",
",",
"eriRouterIcrNotificationGroup",
"}",
"OBJECT",
"eriRouterIcrLocalAddressType",
"SYNTAX",
"InetAddressType",
"{",
"unknown",
"(",
"0",
")",
",",
"ipv4",
"(",
"1",
")",
",",
"ipv6",
"(",
"2",
")",
"}",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required. Only IPv4 and IPv6 addresses require to support.\"",
"OBJECT",
"eriRouterIcrLocalAddress",
"SYNTAX",
"InetAddress",
"(",
"SIZE",
"(",
"0",
"|",
"4",
"|",
"16",
")",
")",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required. Only IPv4 and IPv6 addresses require to support.\"",
"OBJECT",
"eriRouterIcrLocalPort",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"eriRouterIcrPeerAddressType",
"SYNTAX",
"InetAddressType",
"{",
"unknown",
"(",
"0",
")",
",",
"ipv4",
"(",
"1",
")",
",",
"ipv6",
"(",
"2",
")",
"}",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required. Only IPv4 and IPv6 addresses require to support.\"",
"OBJECT",
"eriRouterIcrPeerAddress",
"SYNTAX",
"InetAddress",
"(",
"SIZE",
"(",
"0",
"|",
"4",
"|",
"16",
")",
")",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required. Only IPv4 and IPv6 addresses require to support.\"",
"OBJECT",
"eriRouterIcrPeerPort",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"eriRouterIcrPriority",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"eriRouterIcrKeepAliveInterval",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"eriRouterIcrHoldTime",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"eriRouterIcrAdminStatus",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"OBJECT",
"eriRouterIcrRowStatus",
"MIN-ACCESS",
"read-only",
"DESCRIPTION",
"\"Write access is not required.\"",
"::=",
"{",
"eriRouterIcrMIBCompliances",
"1",
"}"
],
"syntax_tree": [
[
"Status",
"current"
],
[
"DESCRIPTION",
"The compliance statement for ICR MIB implementations."
],
null,
[
"ComplianceModules",
[
[
null,
[
"eriRouterIcrGroup",
"eriRouterIcrNotificationObjectGroup",
"eriRouterIcrNotificationGroup"
]
]
]
]
]
}Vendor MIB copy from the MibBrowser.online archive. Ericsson support.
Module: ERICSSON-ROUTER-ICR-MIB
eriRouterIcrMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for ICR MIB implementations."
MODULE -- this module
MANDATORY-GROUPS {
eriRouterIcrGroup,
eriRouterIcrNotificationObjectGroup,
eriRouterIcrNotificationGroup
}
OBJECT eriRouterIcrLocalAddressType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. Only IPv4 and IPv6 addresses
require to support."
OBJECT eriRouterIcrLocalAddress
SYNTAX InetAddress (SIZE(0|4|16))
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. Only IPv4 and IPv6 addresses
require to support."
OBJECT eriRouterIcrLocalPort
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT eriRouterIcrPeerAddressType
SYNTAX InetAddressType { unknown(0), ipv4(1), ipv6(2) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. Only IPv4 and IPv6 addresses
require to support."
OBJECT eriRouterIcrPeerAddress
SYNTAX InetAddress (SIZE(0|4|16))
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. Only IPv4 and IPv6 addresses
require to support."
OBJECT eriRouterIcrPeerPort
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT eriRouterIcrPriority
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT eriRouterIcrKeepAliveInterval
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT eriRouterIcrHoldTime
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT eriRouterIcrAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT eriRouterIcrRowStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { eriRouterIcrMIBCompliances 1 }{'SNMPv2-TC': ['RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress', 'InetPortNumber'], 'ERICSSON-ROUTER-SMI': ['eriRouterMgmt']}Related source files and packages:
Published package: Ericsson archived MIB 201501141800Z; file: ERICSSON-ROUTER-ICR-MIB.mib.
Native third-party archive copy; vendor association comes from the archive catalog and does not establish a current manufacturer release; Native LAST-UPDATED: 201501141800Z; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:20:58 GMT; 15,554 bytes
Downloaded: 2026-10-27T05:17:07.880672+00:00.