eriRouterIetfTracerouteCap1 — Ericsson MIB copies (MibBrowser.online)
DISMAN-TRACEROUTE-MIB capabilities
{1 3 6 1 4 1 193 218 4 98 1}
DISMAN-TRACEROUTE-MIB capabilities
Status in source: current.
Names: eriRouterIetfTracerouteCap1
{
"smi_kind": "AGENT-CAPABILITIES",
"definition": [
"eriRouterIetfTracerouteCap1",
"AGENT-CAPABILITIES",
"PRODUCT-RELEASE",
[
"literal",
"2253454f5320362e352e31205b53452c20534d5d22"
],
"STATUS",
"current",
"DESCRIPTION",
"\"DISMAN-TRACEROUTE-MIB capabilities\"",
"SUPPORTS",
"DISMAN-TRACEROUTE-MIB",
"INCLUDES",
"{",
"traceRouteGroup",
",",
"traceRouteTimeStampGroup",
",",
"traceRouteNotificationsGroup",
",",
"traceRouteHopsTableGroup",
"}",
"VARIATION",
"traceRouteCtlOwnerIndex",
"DESCRIPTION",
"\"Each character must be printable (the posix function isprint() returns true for each character).\"",
"VARIATION",
"traceRouteCtlTestName",
"DESCRIPTION",
"\"Each character must be printable (the posix function isprint() returns true for each character).\"",
"VARIATION",
"traceRouteCtlTargetAddressType",
"WRITE-SYNTAX",
"INTEGER",
"{",
"unknown",
"(",
"0",
")",
",",
"ipv4",
"(",
"1",
")",
"}",
"DESCRIPTION",
"\"IPv6 and dns address types are not supported.\"",
"VARIATION",
"traceRouteCtlDescr",
"WRITE-SYNTAX",
"OCTET",
"STRING",
"(",
"SIZE",
"(",
"0",
".",
".",
"32",
")",
")",
"DESCRIPTION",
"\"Each character must be printable (the posix function isprint() returns true for each character) and the maximum length is 32 characters.\"",
"VARIATION",
"traceRouteCtlFrequency",
"WRITE-SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"86400",
")",
"DESCRIPTION",
"\"Maximum frequency is 86400 seconds.\"",
"VARIATION",
"traceRouteCtlMaxRows",
"WRITE-SYNTAX",
"Unsigned32",
"(",
"0",
".",
".",
"50",
")",
"DESCRIPTION",
"\"50 is the maximum number of entries allowed in the traceRouteProbeHistoryTable..\"",
"VARIATION",
"traceRouteCtlSourceAddressType",
"WRITE-SYNTAX",
"INTEGER",
"{",
"unknown",
"(",
"0",
")",
",",
"ipv4",
"(",
"1",
")",
"}",
"DESCRIPTION",
"\"IPv4 address types are supported. unknown indicates no source address has been specified.\"",
"VARIATION",
"traceRouteCtlTimeOut",
"WRITE-SYNTAX",
"Unsigned32",
"(",
"2",
".",
".",
"60",
")",
"DESCRIPTION",
"\"Specifies the time-out value, in seconds, for a traceroute request.\"",
"VARIATION",
"traceRouteCtlInitialTtl",
"WRITE-SYNTAX",
"Unsigned32",
"(",
"1",
".",
".",
"30",
")",
"DESCRIPTION",
"\"The value of this object specifies the initial TTL value to use.\"",
"VARIATION",
"traceRouteCtlDataSize",
"WRITE-SYNTAX",
"Unsigned32",
"(",
"40",
".",
".",
"32768",
")",
"DEFVAL",
"{",
"40",
"}",
"DESCRIPTION",
"\"The value of this object specifies the data size.\"",
"::=",
"{",
"eriRouterIetfTracerouteCap",
"1",
"}"
],
"syntax_tree": [
[
"PRODUCT-RELEASE",
"SEOS 6.5.1 [SE, SM]"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"DISMAN-TRACEROUTE-MIB capabilities"
],
null
]
}Vendor MIB copy from the MibBrowser.online archive. Ericsson support.
Module: ERICSSON-ROUTER-IETF-TRACEROUTE-CAP
eriRouterIetfTracerouteCap1 AGENT-CAPABILITIES
PRODUCT-RELEASE "SEOS 6.5.1 [SE, SM]"
STATUS current
DESCRIPTION "DISMAN-TRACEROUTE-MIB capabilities"
SUPPORTS DISMAN-TRACEROUTE-MIB
INCLUDES {
traceRouteGroup,
traceRouteTimeStampGroup,
traceRouteNotificationsGroup,
traceRouteHopsTableGroup
}
VARIATION traceRouteCtlOwnerIndex
DESCRIPTION
"Each character must be printable (the posix function isprint()
returns true for each character)."
VARIATION traceRouteCtlTestName
DESCRIPTION
"Each character must be printable (the posix function isprint()
returns true for each character)."
VARIATION traceRouteCtlTargetAddressType
WRITE-SYNTAX INTEGER {
unknown(0),
ipv4(1)
}
DESCRIPTION
"IPv6 and dns address types are not supported."
VARIATION traceRouteCtlDescr
WRITE-SYNTAX OCTET STRING (SIZE(0..32))
DESCRIPTION
"Each character must be printable (the posix function isprint()
returns true for each character) and the maximum length is 32
characters."
VARIATION traceRouteCtlFrequency
WRITE-SYNTAX Unsigned32 (0..86400)
DESCRIPTION
"Maximum frequency is 86400 seconds."
VARIATION traceRouteCtlMaxRows
WRITE-SYNTAX Unsigned32 (0..50)
DESCRIPTION
"50 is the maximum number of entries allowed in the
traceRouteProbeHistoryTable.."
VARIATION traceRouteCtlSourceAddressType
WRITE-SYNTAX INTEGER {
unknown(0),
ipv4(1)
}
DESCRIPTION
"IPv4 address types are supported. unknown indicates no
source address has been specified."
VARIATION traceRouteCtlTimeOut
WRITE-SYNTAX Unsigned32 (2..60)
DESCRIPTION
"Specifies the time-out value, in seconds, for
a traceroute request."
VARIATION traceRouteCtlInitialTtl
WRITE-SYNTAX Unsigned32 (1..30)
DESCRIPTION
"The value of this object specifies the initial TTL
value to use."
VARIATION traceRouteCtlDataSize
WRITE-SYNTAX Unsigned32 (40..32768)
DEFVAL { 40 }
DESCRIPTION
"The value of this object specifies the data size."
::= { eriRouterIetfTracerouteCap 1 }{'SNMPv2-SMI': ['MODULE-IDENTITY', 'Unsigned32'], 'SNMPv2-CONF': ['AGENT-CAPABILITIES'], 'ERICSSON-ROUTER-SMI': ['eriRouterCapabilities']}Related source files and packages:
Published package: Ericsson archived MIB 201501141800Z; file: ERICSSON-ROUTER-IETF-TRACEROUTE-CAP.mib.
Native third-party archive copy; vendor association comes from the archive catalog and does not establish a current manufacturer release; Native LAST-UPDATED: 201501141800Z; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:20:55 GMT; 4,901 bytes
Downloaded: 2026-10-27T05:17:46.218168+00:00.