saveCfgToNvm — Ericsson MIB copies (MibBrowser.online)
When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM.
{1 3 6 1 4 1 193 72 600 1 1 12}
When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM.
When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM. Using GET command the current (inProgress) or last known state (success or failure) are displayed.
Status in source: current.
Names: saveCfgToNvm
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saveCfgToNvm",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"start",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM.\"",
"::=",
"{",
"commonObjects",
"12",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"start",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM."
],
null,
null,
null,
null
]
}Vendor MIB copy from the MibBrowser.online archive. Ericsson support.
Module: PEA_EQUIPMENT
saveCfgToNvm OBJECT-TYPE
SYNTAX INTEGER {start(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM."
::= { commonObjects 12 }{'PEA-SMI': ['pea'], 'SNMPv2-TC': ['MacAddress'], 'PEM-STANDARD': ['managedObjectClass', 'managedObjectInstance', 'sequenceNumber', 'perceivedSeverity', 'eventTime', 'eventTypePem', 'probableCause']}Related source files and packages:
Published package: Ericsson archived MIB 0302271200Z; file: PEA_EQUIPMENT.mib.
Native third-party archive copy; vendor association comes from the archive catalog and does not establish a current manufacturer release; Native LAST-UPDATED: 0302271200Z; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:20:58 GMT; 45,094 bytes
Downloaded: 2026-10-27T05:19:38.790689+00:00.
Status in source: current.
Names: saveCfgToNvm
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"saveCfgToNvm",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"success",
"(",
"0",
")",
",",
"start",
"(",
"1",
")",
",",
"saveInProgress",
"(",
"2",
")",
",",
"failure",
"(",
"3",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM. Using GET command the current (inProgress) or last known state (success or failure) are displayed.\"",
"::=",
"{",
"commonObjects",
"12",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"success",
0
],
[
"start",
1
],
[
"saveInProgress",
2
],
[
"failure",
3
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM. Using GET command the current (inProgress) or last known state (success or failure) are displayed."
],
null,
null,
null,
null
]
}Vendor MIB copy from the MibBrowser.online archive. Ericsson support.
Module: PEA-EQUIPMENT
saveCfgToNvm OBJECT-TYPE
SYNTAX INTEGER { success (0), start(1), saveInProgress (2), failure (3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When saveCfgToNvm is set to start(1) the device saves the configuration data parameters to NVM.
Using GET command the current (inProgress) or last known state (success or failure) are
displayed."
::= { commonObjects 12 }{'IF-MIB': ['InterfaceIndex', 'ifIndex'], 'PEA-SMI': ['pea'], 'SNMPv2-TC': ['TruthValue', 'DisplayString', 'MacAddress', 'TEXTUAL-CONVENTION'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32', 'IpAddress'], 'SNMPv2-CONF': ['OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'PEM-STANDARD': ['managedObjectClass', 'managedObjectInstance', 'sequenceNumber', 'perceivedSeverity', 'eventTime', 'eventTypePem', 'probableCause']}Related source files and packages:
Published package: Ericsson archived MIB 200508161200Z; file: PEA-EQUIPMENT.mib.
Native third-party archive copy; vendor association comes from the archive catalog and does not establish a current manufacturer release; Native LAST-UPDATED: 200508161200Z; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:21:18 GMT; 120,915 bytes
Downloaded: 2026-10-27T05:19:22.226906+00:00.
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.193.72.600.1.1.1 | versions | 5 | 5 | |
| 1.3.6.1.4.1.193.72.600.1.1.2 | mainProcessor | 4 | 4 | |
| 1.3.6.1.4.1.193.72.600.1.1.3 | temperature | 2 | 2 | |
| 1.3.6.1.4.1.193.72.600.1.1.4 | fansStatus | 6 | 6 | |
| 1.3.6.1.4.1.193.72.600.1.1.5 | alarmFilter | 7 | 7 | |
| 1.3.6.1.4.1.193.72.600.1.1.6 | configurationData | 7 | 7 | |
| 1.3.6.1.4.1.193.72.600.1.1.7 | upgradeSW | 4 | 4 | |
| 1.3.6.1.4.1.193.72.600.1.1.8 | hideInternalInterfaces | 0 | 0 | |
| 1.3.6.1.4.1.193.72.600.1.1.9 | restart | 0 | 0 | |
| 1.3.6.1.4.1.193.72.600.1.1.10 | ledsAltBlink | 0 | 0 | |
| 1.3.6.1.4.1.193.72.600.1.1.11 | startCfgVerification | 0 | 0 | |
| 1.3.6.1.4.1.193.72.600.1.1.13 | cfgVerificationInterval | 0 | 0 | |
| 1.3.6.1.4.1.193.72.600.1.1.14 | notifyType | 0 | 0 | |
| 1.3.6.1.4.1.193.72.600.1.1.15 | identificationData | 4 | 36 | |
| 1.3.6.1.4.1.193.72.600.1.1.16 | sntpServerIP | 0 | 0 | |
| 1.3.6.1.4.1.193.72.600.1.1.17 | snmpKeepAliveTimerTime | 0 | 0 | |
| 1.3.6.1.4.1.193.72.600.1.1.18 | allowBroadcastToDux | 0 | 0 | |
| 1.3.6.1.4.1.193.72.600.1.1.20 | peaMultilink | 4 | 8 | |
| 1.3.6.1.4.1.193.72.600.1.1.21 | comboConnector | 0 | 0 | |
| 1.3.6.1.4.1.193.72.600.1.1.22 | blockUnit | 0 | 0 |