Reference record for OID 1.3.6.1.4.1.193.72.602.10.5.1

Parent
1.3.6.1.4.1.193.72.602.10.5 (bbSeltTestGroup)
Node code
1
Node name
bbSeltTestTable
Numeric OID
1.3.6.1.4.1.193.72.602.10.5.1
URN notation
urn:oid:1.3.6.1.4.1.193.72.602.10.5.1
ASN.1 notation

{1 3 6 1 4 1 193 72 602 10 5 1}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) ericsson(193) diaxMIB(72) peaLineTest(602) bbSelt(10) bbSeltTestGroup(5) bbSeltTestTable(1)}
OID-IRI notation
  • /1/3/6/1/4/1/193/72/602/10/5/1
  • /ISO/Identified-Organization/6/1/4/1/193/72/602/10/5/1
  • /ISO/3/6/1/4/1/193/72/602/10/5/1
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/identified-organization/dod/internet/private/enterprises/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/identified-organization/dod/internet/private/vendor-objects/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/org/dod/internet/private/enterprise/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/org/dod/internet/private/enterprises/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/org/dod/internet/private/ldap-enterprise/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/org/dod/internet/private/vendor-objects/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/iso-identified-organization/dod/internet/private/enterprise/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/iso-identified-organization/dod/internet/private/enterprises/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/iso-organization/dod/internet/private/enterprise/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/iso-organization/dod/internet/private/enterprises/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable
  • /iso/iso-organization/dod/internet/private/vendor-objects/ericsson/diaxMIB/peaLineTest/bbSelt/bbSeltTestGroup/bbSeltTestTable

Descriptions

bbSeltTestTable — Ericsson MIB copies (MibBrowser.online)

This table contains one entry per line. It defines objects which allow a network manager to instruct an agent to test a line for various faults. Tests for a line are defined in the media-specific MIB for that line. After invoking a test, the object bbSeltTestResult can be read to determine the outcome. If an agent can not perform the test, bbSeltTestResult is set to so indicate. The object bbSeltTestCode can be used to provide further test-specific or line-specific (or even enterprise-specific) information concerning the outcome of the test. Only one test can be in progress on each line at any one time. If one test is in progress when another test is invoked, the second test is rejected. Some agents may reject a test when a prior test is active on another line. Before starting a test, a manager-station must first obtain 'ownership' of the entry in the bbSeltTestTable for the line to be tested. This is accomplished with the bbSeltTestId and bbSeltTestStatus objects as follows: try_again: get (bbSeltTestId, bbSeltTestStatus) while (bbSeltTestStatus != notInUse) /* * Loop while a test is running or some other * manager is configuring a test. */ short delay get (bbSeltTestId, bbSeltTestStatus) } /* * Is not being used right now -- let's compete * to see who gets it. */ lock_value = bbSeltTestId if ( set(bbSeltTestId = lock_value, bbSeltTestStatus = inUse, bbSeltTestOwner = 'my-IP-address') == FAILURE) /* * Another manager got the bbSeltTestEntry -- go * try again */ goto try_again; /* * I have the lock */ set up any test parameters. /* * This starts the test */ set(bbSeltTestType = test_to_run); wait for test completion by polling bbSeltTestResult when test completes, agent sets bbSeltTestResult agent also sets bbSeltTestStatus = 'notInUse' retrieve any additional test results, and bbSeltTestId if (bbSeltTestId == lock_value+1) results are valid A manager station first retrieves the value of the appropriate bbSeltTestId and bbSeltTestStatus objects, periodically repeating the retrieval if necessary, until the value of bbSeltTestStatus is 'notInUse'. The manager station then tries to set the same bbSeltTestId object to the value it just retrieved, the same bbSeltTestStatus object to 'inUse', and the corresponding bbSeltTestOwner object to a value indicating itself. If the set operation succeeds then the manager has obtained ownership of the bbSeltTestEntry, and the value of the bbSeltTestId object is incremented by the agent (per the semantics of TestAndIncr). Failure of the set operation indicates that some other manager has obtained ownership of the bbSeltTestEntry. Once ownership is obtained, any test parameters can be setup, and then the test is initiated by setting bbSeltTestType. On completion of the test, the agent sets bbSeltTestStatus to 'notInUse'. Once this occurs, the manager can retrieve the results. In the (rare) event that the invocation of tests by two network managers were to overlap, then there would be a possibility that the first test's results might be overwritten by the second test's results prior to the first results being read. This unlikely circumstance can be detected by a network manager retrieving bbSeltTestId at the same time as retrieving the test results, and ensuring that the results are for the desired request. If bbSeltTestType is not set within an abnormally long period of time after ownership is obtained, the agent should time-out the manager, and reset the value of the bbSeltTestStatus object back to 'notInUse'. It is suggested that this time-out period be 5 minutes. In general, a management station must not retransmit a request to invoke a test for which it does not receive a response; instead, it properly inspects an agent's MIB to determine if the invocation was successful. Only if the invocation was unsuccessful, is the invocation request retransmitted. Some tests may require the line to be taken off- line in order to execute them, or may even require the agent to reboot after completion of the test. In these circumstances, communication with the management station invoking the test may be lost until after completion of the test. An agent is not required to support such tests. However, if such tests are supported, then the agent should make every effort to transmit a response to the request which invoked the test prior to losing communication. When the agent is restored to normal service, the results of the test are properly made available in the appropriate objects. Note that this requires that the lineIndex value assigned to a line must be unchanged even if the test causes a reboot. An agent must reject any test for which it cannot, perhaps due to resource constraints, make available at least the minimum amount of information after that test completes.

Source records

bbSeltTestTable

Status in source: current.

Names: bbSeltTestTable

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "bbSeltTestTable",
    "OBJECT-TYPE",
    "SYNTAX",
    "SEQUENCE",
    "OF",
    "BbSeltTestEntry",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"This table contains one entry per line. It defines objects which allow a network manager to instruct an agent to test a line for various faults. Tests for a line are defined in the media-specific MIB for that line. After invoking a test, the object bbSeltTestResult can be read to determine the outcome. If an agent can not perform the test, bbSeltTestResult is set to so indicate. The object bbSeltTestCode can be used to provide further test-specific or line-specific (or even enterprise-specific) information concerning the outcome of the test. Only one test can be in progress on each line at any one time. If one test is in progress when another test is invoked, the second test is rejected. Some agents may reject a test when a prior test is active on another line. Before starting a test, a manager-station must first obtain 'ownership' of the entry in the bbSeltTestTable for the line to be tested. This is accomplished with the bbSeltTestId and bbSeltTestStatus objects as follows: try_again: get (bbSeltTestId, bbSeltTestStatus) while (bbSeltTestStatus != notInUse) /* * Loop while a test is running or some other * manager is configuring a test. */ short delay get (bbSeltTestId, bbSeltTestStatus) } /* * Is not being used right now -- let's compete * to see who gets it. */ lock_value = bbSeltTestId if ( set(bbSeltTestId = lock_value, bbSeltTestStatus = inUse, bbSeltTestOwner = 'my-IP-address') == FAILURE) /* * Another manager got the bbSeltTestEntry -- go * try again */ goto try_again; /* * I have the lock */ set up any test parameters. /* * This starts the test */ set(bbSeltTestType = test_to_run); wait for test completion by polling bbSeltTestResult when test completes, agent sets bbSeltTestResult agent also sets bbSeltTestStatus = 'notInUse' retrieve any additional test results, and bbSeltTestId if (bbSeltTestId == lock_value+1) results are valid A manager station first retrieves the value of the appropriate bbSeltTestId and bbSeltTestStatus objects, periodically repeating the retrieval if necessary, until the value of bbSeltTestStatus is 'notInUse'. The manager station then tries to set the same bbSeltTestId object to the value it just retrieved, the same bbSeltTestStatus object to 'inUse', and the corresponding bbSeltTestOwner object to a value indicating itself. If the set operation succeeds then the manager has obtained ownership of the bbSeltTestEntry, and the value of the bbSeltTestId object is incremented by the agent (per the semantics of TestAndIncr). Failure of the set operation indicates that some other manager has obtained ownership of the bbSeltTestEntry. Once ownership is obtained, any test parameters can be setup, and then the test is initiated by setting bbSeltTestType. On completion of the test, the agent sets bbSeltTestStatus to 'notInUse'. Once this occurs, the manager can retrieve the results. In the (rare) event that the invocation of tests by two network managers were to overlap, then there would be a possibility that the first test's results might be overwritten by the second test's results prior to the first results being read. This unlikely circumstance can be detected by a network manager retrieving bbSeltTestId at the same time as retrieving the test results, and ensuring that the results are for the desired request. If bbSeltTestType is not set within an abnormally long period of time after ownership is obtained, the agent should time-out the manager, and reset the value of the bbSeltTestStatus object back to 'notInUse'. It is suggested that this time-out period be 5 minutes. In general, a management station must not retransmit a request to invoke a test for which it does not receive a response; instead, it properly inspects an agent's MIB to determine if the invocation was successful. Only if the invocation was unsuccessful, is the invocation request retransmitted. Some tests may require the line to be taken off- line in order to execute them, or may even require the agent to reboot after completion of the test. In these circumstances, communication with the management station invoking the test may be lost until after completion of the test. An agent is not required to support such tests. However, if such tests are supported, then the agent should make every effort to transmit a response to the request which invoked the test prior to losing communication. When the agent is restored to normal service, the results of the test are properly made available in the appropriate objects. Note that this requires that the lineIndex value assigned to a line must be unchanged even if the test causes a reboot. An agent must reject any test for which it cannot, perhaps due to resource constraints, make available at least the minimum amount of information after that test completes.\"",
    "::=",
    "{",
    "bbSeltTestGroup",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "conceptualTable",
      [
        "row",
        "BbSeltTestEntry"
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "This table contains one entry per line. It defines objects which allow a network manager to instruct an agent to test a line for various faults. Tests for a line are defined in the media-specific MIB for that line. After invoking a test, the object bbSeltTestResult can be read to determine the outcome. If an agent can not perform the test, bbSeltTestResult is set to so indicate. The object bbSeltTestCode can be used to provide further test-specific or line-specific (or even enterprise-specific) information concerning the outcome of the test. Only one test can be in progress on each line at any one time. If one test is in progress when another test is invoked, the second test is rejected. Some agents may reject a test when a prior test is active on another line. Before starting a test, a manager-station must first obtain 'ownership' of the entry in the bbSeltTestTable for the line to be tested. This is accomplished with the bbSeltTestId and bbSeltTestStatus objects as follows: try_again: get (bbSeltTestId, bbSeltTestStatus) while (bbSeltTestStatus != notInUse) /* * Loop while a test is running or some other * manager is configuring a test. */ short delay get (bbSeltTestId, bbSeltTestStatus) } /* * Is not being used right now -- let's compete * to see who gets it. */ lock_value = bbSeltTestId if ( set(bbSeltTestId = lock_value, bbSeltTestStatus = inUse, bbSeltTestOwner = 'my-IP-address') == FAILURE) /* * Another manager got the bbSeltTestEntry -- go * try again */ goto try_again; /* * I have the lock */ set up any test parameters. /* * This starts the test */ set(bbSeltTestType = test_to_run); wait for test completion by polling bbSeltTestResult when test completes, agent sets bbSeltTestResult agent also sets bbSeltTestStatus = 'notInUse' retrieve any additional test results, and bbSeltTestId if (bbSeltTestId == lock_value+1) results are valid A manager station first retrieves the value of the appropriate bbSeltTestId and bbSeltTestStatus objects, periodically repeating the retrieval if necessary, until the value of bbSeltTestStatus is 'notInUse'. The manager station then tries to set the same bbSeltTestId object to the value it just retrieved, the same bbSeltTestStatus object to 'inUse', and the corresponding bbSeltTestOwner object to a value indicating itself. If the set operation succeeds then the manager has obtained ownership of the bbSeltTestEntry, and the value of the bbSeltTestId object is incremented by the agent (per the semantics of TestAndIncr). Failure of the set operation indicates that some other manager has obtained ownership of the bbSeltTestEntry. Once ownership is obtained, any test parameters can be setup, and then the test is initiated by setting bbSeltTestType. On completion of the test, the agent sets bbSeltTestStatus to 'notInUse'. Once this occurs, the manager can retrieve the results. In the (rare) event that the invocation of tests by two network managers were to overlap, then there would be a possibility that the first test's results might be overwritten by the second test's results prior to the first results being read. This unlikely circumstance can be detected by a network manager retrieving bbSeltTestId at the same time as retrieving the test results, and ensuring that the results are for the desired request. If bbSeltTestType is not set within an abnormally long period of time after ownership is obtained, the agent should time-out the manager, and reset the value of the bbSeltTestStatus object back to 'notInUse'. It is suggested that this time-out period be 5 minutes. In general, a management station must not retransmit a request to invoke a test for which it does not receive a response; instead, it properly inspects an agent's MIB to determine if the invocation was successful. Only if the invocation was unsuccessful, is the invocation request retransmitted. Some tests may require the line to be taken off- line in order to execute them, or may even require the agent to reboot after completion of the test. In these circumstances, communication with the management station invoking the test may be lost until after completion of the test. An agent is not required to support such tests. However, if such tests are supported, then the agent should make every effort to transmit a response to the request which invoked the test prior to losing communication. When the agent is restored to normal service, the results of the test are properly made available in the appropriate objects. Note that this requires that the lineIndex value assigned to a line must be unchanged even if the test causes a reboot. An agent must reject any test for which it cannot, perhaps due to resource constraints, make available at least the minimum amount of information after that test completes."
    ],
    null,
    null,
    null,
    null
  ]
}
  • Ericsson MIB copies (MibBrowser.online) · Publisher's source file: PEA-BB-SELT — archive MIB indexed for Ericsson

    Vendor MIB copy from the MibBrowser.online archive. Ericsson support.

    Module: PEA-BB-SELT

    Published definition
    bbSeltTestTable   OBJECT-TYPE
        SYNTAX      SEQUENCE OF BbSeltTestEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
        "This table contains one entry per line.  It
         defines objects which allow a network manager to
         instruct an agent to test a line for various
         faults.  Tests for a line are defined in the
         media-specific MIB for that line.  After invoking
         a test, the object bbSeltTestResult can be read to
         determine the outcome.  If an agent can not perform
         the test, bbSeltTestResult is set to so indicate.  The
         object bbSeltTestCode can be used to provide further
         test-specific or line-specific (or even
         enterprise-specific) information concerning the
         outcome of the test.  Only one test can be in progress
         on each line at any one time.  If one test is in
         progress when another test is invoked, the second test
         is rejected.  Some agents may reject a test when a
         prior test is active on another line.
    
         Before starting a test, a manager-station must first
         obtain 'ownership' of the entry in the bbSeltTestTable for
         the line to be tested.  This is accomplished with
         the bbSeltTestId and bbSeltTestStatus objects as follows:
    
             try_again:
                    get (bbSeltTestId, bbSeltTestStatus)
                    while (bbSeltTestStatus != notInUse)
                        /*      
                         * Loop while a test is running or some other
                         * manager is configuring a test.
                         */
                        short delay
                        get (bbSeltTestId, bbSeltTestStatus)
                    }
    
                    /*
                     * Is not being used right now -- let's compete
                     * to see who gets it.
                     */
                    lock_value = bbSeltTestId
    
                    if ( set(bbSeltTestId = lock_value, bbSeltTestStatus = inUse,
                             bbSeltTestOwner = 'my-IP-address') == FAILURE)
                        /*
                         * Another manager got the bbSeltTestEntry -- go
                         * try again
                         */
                        goto try_again;
    
                    /*
                     * I have the lock
                     */
                    set up any test parameters.
    
                    /*
                     * This starts the test
                     */
                    set(bbSeltTestType = test_to_run);
    
                    wait for test completion by polling bbSeltTestResult
    
                    when test completes, agent sets bbSeltTestResult
                         agent also sets bbSeltTestStatus = 'notInUse'
    
                    retrieve any additional test results, and bbSeltTestId
    
                    if (bbSeltTestId == lock_value+1) results are valid
    
                  A manager station first retrieves the value of the
                  appropriate bbSeltTestId and bbSeltTestStatus objects,
                  periodically repeating the retrieval if necessary,
                  until the value of bbSeltTestStatus is 'notInUse'.  The
                  manager station then tries to set the same bbSeltTestId
                  object to the value it just retrieved, the same
                  bbSeltTestStatus object to 'inUse', and the corresponding
                  bbSeltTestOwner object to a value indicating itself.  If
                  the set operation succeeds then the manager has
                  obtained ownership of the bbSeltTestEntry, and the value of
                  the bbSeltTestId object is incremented by the agent (per
                  the semantics of TestAndIncr).  Failure of the set
                  operation indicates that some other manager has
                  obtained ownership of the bbSeltTestEntry.
    
                  Once ownership is obtained, any test parameters can be
                  setup, and then the test is initiated by setting
                  bbSeltTestType.  On completion of the test, the agent sets
                  bbSeltTestStatus to 'notInUse'.  Once this occurs, the
                  manager can retrieve the results.  In the (rare) event
                  that the invocation of tests by two network managers
                  were to overlap, then there would be a possibility that
                  the first test's results might be overwritten by the
                  second test's results prior to the first results being
                  read.  This unlikely circumstance can be detected by a
                  network manager retrieving bbSeltTestId at the same time as
                  retrieving the test results, and ensuring that the
                  results are for the desired request.
    
                  If bbSeltTestType is not set within an abnormally long
                  period of time after ownership is obtained, the agent
                  should time-out the manager, and reset the value of the
                  bbSeltTestStatus object back to 'notInUse'.  It is
                  suggested that this time-out period be 5 minutes.
    
                  In general, a management station must not retransmit a
                  request to invoke a test for which it does not receive
                  a response; instead, it properly inspects an agent's
                  MIB to determine if the invocation was successful.
                  Only if the invocation was unsuccessful, is the
                  invocation request retransmitted.
    
                  Some tests may require the line to be taken off-
                  line in order to execute them, or may even require the
                  agent to reboot after completion of the test.  In these
                  circumstances, communication with the management
                  station invoking the test may be lost until after
                  completion of the test.  An agent is not required to
                  support such tests.  However, if such tests are
                  supported, then the agent should make every effort to
                  transmit a response to the request which invoked the
                  test prior to losing communication.  When the agent is
                  restored to normal service, the results of the test are
                  properly made available in the appropriate objects.
                  Note that this requires that the lineIndex value assigned
                  to a line must be unchanged even if the test
                  causes a reboot.  An agent must reject any test for
                  which it cannot, perhaps due to resource constraints,
                  make available at least the minimum amount of
                  information after that test completes."
        ::= { bbSeltTestGroup 1 }
    Module imports
    {'IF-MIB': ['ifIndex', 'OwnerString'], 'SNMPv2-TC': ['TruthValue', 'DisplayString', 'PhysAddress', 'AutonomousType', 'TestAndIncr'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'NOTIFICATION-TYPE', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'IpAddress', 'TimeTicks', 'Gauge32'], 'PEM-STANDARD': ['managedObjectClass', 'managedObjectInstance', 'sequenceNumber', 'perceivedSeverity', 'eventTime', 'eventTypePem', 'probableCause'], 'PEM-STANDARD-TC': ['IANAItuProbableCause'], 'PEA-LINE-TEST-SMI': ['peaLineTest'], 'PEA-BRIDGE-IPDSLAM': ['lineIndex']}
    · Download PEA-BB-SELT — archive MIB indexed for Ericsson

    Related source files and packages:

    • IF-MIB — dependency MIB (MibBrowser.online)Native third-party archive dependency for Ericsson MIB imports; authorship is not attributed to that manufacturer; Native LAST-UPDATED: 200006140000Z; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:21:05 GMT; 71,777 bytes
    • PEA-BRIDGE-IPDSLAM — archive MIB indexed for EricssonNative third-party archive copy; vendor association comes from the archive catalog and does not establish a current manufacturer release; Native LAST-UPDATED: 200604251200Z; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:21:13 GMT; 256,722 bytes
    • PEA-LINE-TEST-SMI — archive MIB indexed for EricssonNative third-party archive copy; vendor association comes from the archive catalog and does not establish a current manufacturer release; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:21:11 GMT; 401 bytes
    Show all 7 related files and packages
    • PEM-STANDARD — archive MIB indexed for EricssonNative third-party archive copy; vendor association comes from the archive catalog and does not establish a current manufacturer release; Native LAST-UPDATED: 200602020000Z; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:21:11 GMT; 4,298 bytes
    • PEM-STANDARD-TC — archive MIB indexed for EricssonNative third-party archive copy; vendor association comes from the archive catalog and does not establish a current manufacturer release; Native LAST-UPDATED: 200204101235Z; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:21:02 GMT; 10,495 bytes
    • SNMPv2-SMI — dependency MIB (MibBrowser.online)Native third-party archive dependency for Ericsson MIB imports; authorship is not attributed to that manufacturer; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:21:04 GMT; 10,283 bytes
    • SNMPv2-TC — dependency MIB (MibBrowser.online)Native third-party archive dependency for Ericsson MIB imports; authorship is not attributed to that manufacturer; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:21:11 GMT; 38,034 bytes

    Source location: PEA-BB-SELT::bbSeltTestTable.
    Source version and references

    Published package: Ericsson archived MIB 200503180000Z; file: PEA-BB-SELT.mib.

    Native third-party archive copy; vendor association comes from the archive catalog and does not establish a current manufacturer release; Native LAST-UPDATED: 200503180000Z; Copy from MibBrowser.online; Publisher Last-Modified: Sun, 01 Oct 2023 19:20:58 GMT; 23,826 bytes

    Downloaded: 2026-10-27T05:19:18.423956+00:00.

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.193)

David Partain

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.193)

Daniel Farias

Direct children (1)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.193.72.602.10.5.1.1 bbSeltTestEntry77