Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"xfPMRLTS2Threshold",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"-",
"998",
".",
".",
"-",
"200",
")",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"RLTS2 Alarm Threshold for Minimum RF Input Power. RF input level = value/10 dBm. Domain: [-99.8 ... -20.0 dBm] Valid for both 15 m & 24 h intervals. If changed current interval PM data must be reset. Always greater than RLTS1, xfPMRLTS1Threshold.\"",
"DEFVAL",
"{",
"-",
"998",
"}",
"::=",
"{",
"xfRLPMConfigEntry",
"15",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
-998,
-200
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"RLTS2 Alarm Threshold for Minimum RF Input Power. RF input level = value/10 dBm. Domain: [-99.8 ... -20.0 dBm] Valid for both 15 m & 24 h intervals. If changed current interval PM data must be reset. Always greater than RLTS1, xfPMRLTS1Threshold."
],
null,
null,
null,
[
"DEFVAL",
-998
]
]
}