Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"mcrMgtLedALM",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"offNoAlarms",
"(",
"0",
")",
",",
"onRedAlarmsPresent",
"(",
"1",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"This object identifies the status of the alarm (ALM) LED on the management module. Possible status values are: offNoAlarms(0) - Normal operating condition onRedAlarmsPresent(1) - System hardware or software alarms present\"",
"::=",
"{",
"mcrMgtLedEntry",
"4",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"offNoAlarms",
0
],
[
"onRedAlarmsPresent",
1
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This object identifies the status of the alarm (ALM) LED on the management module. Possible status values are: offNoAlarms(0) - Normal operating condition onRedAlarmsPresent(1) - System hardware or software alarms present"
],
null,
null,
null,
null
]
}