nvramFailingAlarm

1.3.6.1.4.1.19746.2.0.6

Description

Meaning: The system has detected that the NVRAM is potentially failing. There has been an excessive amount of PCI or Memory errors. The nvram tables 'nvramProperties' and 'nvramStats' may provide for information on why the NVRAM is failing. What to do: check the status of the NVRAM after reboot, and replace if the err…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.19746.2.0 (dataDomainMibTraps)
Node code
6
Node name
nvramFailingAlarm
Category
SNMP notification
Numeric OID
1.3.6.1.4.1.19746.2.0.6
URN notation
urn:oid:1.3.6.1.4.1.19746.2.0.6
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 19746 2 0 6}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) dataDomainMib(19746) dataDomainMibNotifications(2) dataDomainMibTraps(0) nvramFailingAlarm(6)}
OID-IRI notation
  • /1/3/6/1/4/1/19746/2/0/6
  • /ISO/Identified-Organization/6/1/4/1/19746/2/0/6
  • /ISO/3/6/1/4/1/19746/2/0/6
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/identified-organization/dod/internet/private/enterprises/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/identified-organization/dod/internet/private/vendor-objects/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/org/dod/internet/private/enterprise/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/org/dod/internet/private/enterprises/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/org/dod/internet/private/ldap-enterprise/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/org/dod/internet/private/vendor-objects/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/iso-identified-organization/dod/internet/private/enterprise/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/iso-identified-organization/dod/internet/private/enterprises/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/iso-organization/dod/internet/private/enterprise/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/iso-organization/dod/internet/private/enterprises/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm
  • /iso/iso-organization/dod/internet/private/vendor-objects/dataDomainMib/dataDomainMibNotifications/dataDomainMibTraps/nvramFailingAlarm

The displayed source records contain one distinct definition. Compare its source records.

nvramFailingAlarm NOTIFICATION-TYPE
	STATUS deprecated	
        DESCRIPTION
            "Meaning: The system has detected that the NVRAM is potentially failing.  There has
            been an excessive amount of PCI or Memory errors. The nvram tables 'nvramProperties'
            and 'nvramStats' may provide for information on why the NVRAM is failing.
            What to do: check the status of the NVRAM after reboot, and replace if the
            errors continue."
        ::= { dataDomainMibTraps 6 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Meaning: The system has detected that the NVRAM is potentially failing. There has been an excessive amount of PCI or Memory errors. The nvram tables 'nvramProperties' and 'nvramStats' may provide for information on why the NVRAM is failing. What to do: check the status of the NVRAM after reboot, and replace if the errors continue.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 1

nvramFailingAlarm · deprecatedMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: deprecated.

Names: nvramFailingAlarm

Technical details
{
  "smi_kind": "NOTIFICATION-TYPE",
  "definition": [
    "nvramFailingAlarm",
    "NOTIFICATION-TYPE",
    "STATUS",
    "deprecated",
    "DESCRIPTION",
    "\"Meaning: The system has detected that the NVRAM is potentially failing. There has been an excessive amount of PCI or Memory errors. The nvram tables 'nvramProperties' and 'nvramStats' may provide for information on why the NVRAM is failing. What to do: check the status of the NVRAM after reboot, and replace if the errors continue.\"",
    "::=",
    "{",
    "dataDomainMibTraps",
    "6",
    "}"
  ],
  "syntax_tree": [
    [],
    [
      "Status",
      "deprecated"
    ],
    [
      "DESCRIPTION",
      "Meaning: The system has detected that the NVRAM is potentially failing. There has been an excessive amount of PCI or Memory errors. The nvram tables 'nvramProperties' and 'nvramStats' may provide for information on why the NVRAM is failing. What to do: check the status of the NVRAM after reboot, and replace if the errors continue."
    ],
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.19746)

Haile J. Mitchell

Siblings (246)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.19746.2.0.1 powerSupplyFailedAlarm00
1.3.6.1.4.1.19746.2.0.2 systemOverheatWarningAlarm00
1.3.6.1.4.1.19746.2.0.3 systemOverheatAlertAlarm00
1.3.6.1.4.1.19746.2.0.4 systemOverheatShutdownAlarm00
1.3.6.1.4.1.19746.2.0.5 fanModuleFailedAlarm00
1.3.6.1.4.1.19746.2.0.7 fileSystemFailedAlarm00
1.3.6.1.4.1.19746.2.0.8 fileSpaceMaintenanceAlarm00
1.3.6.1.4.1.19746.2.0.9 fileSpacePreWarningAlarm00
1.3.6.1.4.1.19746.2.0.10 fileSpaceWarningAlarm00
1.3.6.1.4.1.19746.2.0.11 fileSpaceSevereAlarm00
1.3.6.1.4.1.19746.2.0.12 fileSpaceCriticalAlarm00
1.3.6.1.4.1.19746.2.0.14 diskFailedAlarm00
1.3.6.1.4.1.19746.2.0.15 diskOverheatWarningAlarm00
1.3.6.1.4.1.19746.2.0.16 diskOverheatAlertAlarm00
1.3.6.1.4.1.19746.2.0.17 diskOverheatShutdownAlarm00
1.3.6.1.4.1.19746.2.0.18 raidReconSevereAlarm00
1.3.6.1.4.1.19746.2.0.19 raidReconCriticalAlarm00
1.3.6.1.4.1.19746.2.0.20 raidReconCriticalShutdownAlarm00
1.3.6.1.4.1.19746.2.0.21 raidGroupMissingAlarm00
1.3.6.1.4.1.19746.2.0.22 diskNoSpareAlarm00
1.3.6.1.4.1.19746.2.0.23 diskPathAlarm00
1.3.6.1.4.1.19746.2.0.24 diskSASAlarm00
1.3.6.1.4.1.19746.2.0.25 diskSASHBAAlarm00
1.3.6.1.4.1.19746.2.0.26 snapshotFullAlarm00
1.3.6.1.4.1.19746.2.0.27 snapshotHWMAlarm00
1.3.6.1.4.1.19746.2.0.28 clusterNodeAlarm00
1.3.6.1.4.1.19746.2.0.29 clusterInterfaceAlarm00
1.3.6.1.4.1.19746.2.0.30 replSyncAlarm00
1.3.6.1.4.1.19746.2.0.31 systemStartupAlarm00
1.3.6.1.4.1.19746.2.0.32 filesysRelaunchAlarm00
1.3.6.1.4.1.19746.2.0.33 filesysDDGCFailedAlarm00
1.3.6.1.4.1.19746.2.0.34 filesysGeneralProblemAlarm00
1.3.6.1.4.1.19746.2.0.35 diskUnsupportedAlarm00
1.3.6.1.4.1.19746.2.0.36 eventIPMIUnmanageAlarm00
1.3.6.1.4.1.19746.2.0.5002 controllerUnreachableAlert00
1.3.6.1.4.1.19746.2.0.5003 controllerIfaceUnreachableAlert00
1.3.6.1.4.1.19746.2.0.5004 correctableECCLimitReached00
1.3.6.1.4.1.19746.2.0.5005 uncorrectableECCerror00
1.3.6.1.4.1.19746.2.0.5006 legacyChassisTempWarning00
1.3.6.1.4.1.19746.2.0.5007 legacyChassisTempCritical00
1.3.6.1.4.1.19746.2.0.5008 legacyPowerSupplyWarning00
1.3.6.1.4.1.19746.2.0.5009 legacyFanWarning00
1.3.6.1.4.1.19746.2.0.5010 powerSupplyWarning00
1.3.6.1.4.1.19746.2.0.5011 fanWarning00
1.3.6.1.4.1.19746.2.0.5012 voltageWarning00
1.3.6.1.4.1.19746.2.0.5013 powerWarning00
1.3.6.1.4.1.19746.2.0.5014 correctECCWarning00
1.3.6.1.4.1.19746.2.0.5016 processorWarning00
1.3.6.1.4.1.19746.2.0.5017 powerUnitWarning00
1.3.6.1.4.1.19746.2.0.5018 unCorrectECCWarning00