This variable defines the minimum interval, in microseconds, that the interface would like to use when transmitting BFD Control packets.
Sources for this description
H3C and HH3C MIB copies (Observium Community)Netdisco MIB archive copies
OID reference
1.3.6.1.4.1.2011.10.2.72.1.2.1.2
This variable defines the minimum interval, in microseconds, that the interface would like to use when transmitting BFD Control packets.
Identification
{1 3 6 1 4 1 2011 10 2 72 1 2 1 2}
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Available source records contain 2 distinct definitions; some records may not include a definition.
h3cBfdIfDesiredMinTxInterval OBJECT-TYPE
SYNTAX BfdInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the minimum interval, in
microseconds, that the interface would like to use when
transmitting BFD Control packets."
::= { h3cBfdIfEntry 2 }h3cBfdIfDesiredMinTxInterval OBJECT-TYPE
SYNTAX BfdInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the minimum interval, in
microseconds, that the interface would like to use when
transmitting BFD Control packets."
::= { h3cBfdIfEntry 2 }
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
This variable defines the minimum interval, in microseconds, that the interface would like to use when transmitting BFD Control packets.
H3C and HH3C MIB copies (Observium Community)Netdisco MIB archive copies
Evidence
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Status in source: current.
Names: h3cBfdIfDesiredMinTxInterval
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"h3cBfdIfDesiredMinTxInterval",
"OBJECT-TYPE",
"SYNTAX",
"BfdInterval",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"This variable defines the minimum interval, in microseconds, that the interface would like to use when transmitting BFD Control packets.\"",
"::=",
"{",
"h3cBfdIfEntry",
"2",
"}"
],
"syntax_tree": [
[
"row",
"BfdInterval"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"This variable defines the minimum interval, in microseconds, that the interface would like to use when transmitting BFD Control packets."
],
null,
null,
null,
null
]
}Vendor MIB copy from the Observium Community archive. H3C and HH3C support.
Module: H3C-BFD-STD-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Counter64', 'NOTIFICATION-TYPE'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'HUAWEI-3COM-OID-MIB': ['h3cCommon']}Related source files and packages:
Vendor MIB copy from the Netdisco archive.
Module: H3C-BFD-STD-MIB
See published definition above
{'IF-MIB': ['InterfaceIndex'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TruthValue', 'RowStatus', 'StorageType', 'TimeStamp'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Counter32', 'Counter64', 'NOTIFICATION-TYPE', 'mib-2'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType', 'InetPortNumber'], 'HUAWEI-3COM-OID-MIB': ['h3cCommon']}Related source files and packages:
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.10.2.72.1.2.1.1 | h3cBfdIfIndex | 0 | 0 | |
| 1.3.6.1.4.1.2011.10.2.72.1.2.1.3 | h3cBfdIfDesiredMinRxInterval | 0 | 0 | |
| 1.3.6.1.4.1.2011.10.2.72.1.2.1.4 | h3cBfdIfDetectMult | 0 | 0 | |
| 1.3.6.1.4.1.2011.10.2.72.1.2.1.5 | h3cBfdIfAuthType | 0 | 0 |